Eaton Magnum low-voltage MPSC6N3WEAXX2S breaker - UL Listed
Part Number: MPSC6N3WEAXX2S
Quick Summary
Eaton Magnum low voltage power circuit breaker safeguards distribution panels in industrial facilities, preventing overloads and short circuits. In harsh environments, uptime hinges on reliable trip behavior and straightforward maintenance, which this unit delivers. The assembly carries UL Listed and CE Marked protections, with ANSI and CSA certifications supporting global compliance and safe operation. With Power Xpert Release trip units and a drawout vertical mounting design, it integrates seamlessly into modern protection schemes while reducing wiring complexity and installation time. This combination translates to higher system availability, faster commissioning, and lower total cost of ownership for panel builders and utilities.
Product Information
Extended Description
MPSC6N3WEAXX2S Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (AABBCC), 100 kA, Three-pole, Drawout vertical mounting, PXR25 LSIGAM trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC6N3WEAXX2S
UPC
786689629885
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CCC Marked NEMA Compliant SABA Listed CE Marked
Certifications
ANSI Lloyd's Register Certified CSA Certified KEMA Certified UL Listed DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC6N3WEAXX2S
Eaton Specification Sheet - MPSC6N3WEAXX2S
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Cyber security white paper
Cyber security white paper
Cyber security white paper
Three-pole construction with drawout vertical mounting enables straightforward replacement and safe alignment in existing switchgear, cutting downtime during maintenance. The PXR25 LSIGAM trip unit provides flexible protection settings and improved coordination, reducing nuisance trips and enabling selective protection in complex networks. A 100 kA short-circuit rating and a robust 6000 A frame deliver strong fault tolerance for heavy-industrial feeds, improving reliability in critical applications like motors and conveyors. Fan-cooled design enhances heat dissipation in crowded enclosures, supporting sustained performance in high-load scenarios. Precise dimensions (16.3 in depth, 16.8 in height, 31.1 in width) and a substantial 237 lb mass reflect a durable build that withstands rugged factory environments. Certifications including UL Listed, CE Marked, CSA, and ANSI compliance support worldwide installation and regulatory requirements. The Magnum PXR trip unit ecosystem enables advanced protection strategies while maintaining compatibility with Power Xpert Protection Manager workflows.
Get a Quick Quote for a Eaton MPSC6N3WEAXX2S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC6N3WEAXX2S?
Enquire Now
FAQs
Yes. The MPSC6N3WEAXX2S features drawout vertical mounting designed for straightforward replacement in compatible switchgear. Its 3-pole construction and pre-wired PXR trip unit simplify wiring, while the expansive dimensions and weight indicate a robust, field-serviceable unit. Installation benefits include reduced commissioning time and clear ergonomic access for maintenance personnel.
The unit uses a PXR25 LSIGAM trip unit, offering adjustable protection settings for selective coordination. It supports a high fault current rating of up to 100 kA (short-circuit capacity) with a 6000 A frame, enabling reliable protection for heavy-load feeders and motor circuits in demanding industrial environments.
Absolutely. Its three-pole design, drawout mounting, and robust protection features make it suitable for motor control centers and critical manufacturing feeders. The PXR trip unit allows tailored motor protection curves, improving start-up sequences and reducing startup shocks. Its fan-cooled construction supports continuous operation in demanding line environments.
The MPSC6N3WEAXX2S carries UL Listed and CE Marked certifications, along with ANSI, CSA, and other global attestations. This mix supports compliance across North American and international markets, streamlining procurement and reducing regulatory barriers for equipment in global projects.
Power Xpert Release (PXR) provides modular protection management with advanced trip-unit settings, enabling faster diagnostics and easier updates. This reduces downtime during fault events and simplifies preventive maintenance. When integrated with Eaton’s protection ecosystem, it yields improved trend analysis, proactive issue identification, and a lower total cost of ownership over the breaker’s lifespan.