Eaton MPSC6N4MEAXX2Q Magnum circuit breaker - UL Listed

Part Number: MPSC6N4MEAXX2Q
Manufacturer
Eaton
Part number
MPSC6N4MEAXX2Q

Quick Summary

The Eaton Magnum low voltage power circuit breaker protects distribution panels by interrupting fault currents in industrial automation setups. Industrial facilities face costly downtime when protection devices trip unnecessarily or require lengthy maintenance. This unit carries CE Marked, UL Listed, and ANSI CSA certifications, ensuring regulatory compliance across global installations. With the PXR25 LSIAM trip unit and motorized racking, technicians gain precise coordination and safer, faster operations. Coupled with a four-pole design and fan cooling, it supports reliable motor control and scalable protection in panels. The robust 6000 A frame and 100 kA interrupt capacity make it a dependable choice for high-demand environments while aligning with Power Xpert protection strategies.

Product Information

Extended Description

MPSC6N4MEAXX2Q Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NNAABBCC), 100 kA, Four-pole, Drawout vertical with motorized racking mounting, PXR25 LSIAM trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC6N4MEAXX2Q
UPC
786689629830
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CE Marked NEMA Compliant CCC Marked SABA Listed
Certifications
ANSI CSA Certified UL Listed KEMA Certified Lloyd's Register Certified ABS Certified DNV GL Certified
Feature: Drawout vertical with motorized racking mounting enables safe, rapid breaker replacement while panels are accessible, reducing arc exposure and downtime. Business Impact: Faster maintenance cycles and safer work, lower labor costs, and less production interruption. Application: Motor control centers (MCCs) and switchgear enclosures in manufacturing plants. Feature: PXR25 LSIAM trip unit provides configurable protection with precise coordination. Business Impact: Improved selectivity, minimized nuisance trips, and easier tuning for varied loads. Application: Critical equipment and process lines requiring reliable protection curves. Feature: Four-pole design with a 6000 A frame and 100 kA interrupt rating supports high fault-current environments. Business Impact: Enhanced system integrity, reduced risk of cascading faults, and longer equipment life. Application: Large drives, pumps, and heavy motor loads in industrial facilities. Feature: Fan-cooled construction maintains breaker performance in confined panels and higher ambient temperatures. Business Impact: Consistent protection performance, lower overheating risk, and reduced maintenance intervals. Application: Dense panel layouts and harsh production environments. Feature: Broad certifications and compliance (UL Listed, CE Marked, ANSI CSA, KEMA, etc.) provide procurement flexibility and faster approval in global projects. Business Impact: Streamlined supplier vetting, lower project risk, and easier cross-border commissioning. Application: Global rollouts and multi-site installations. Feature: Compatibility with Power Xpert Protection Manager and motorized racking supports scalable protection architectures. Business Impact: Centralized monitoring, simplified updates, and improved change management. Application: Modern industrial networks requiring integrated protection workflows.

Get a Quick Quote for a Eaton MPSC6N4MEAXX2Q

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPSC6N4MEAXX2Q? Enquire Now

FAQs

This Magnum circuit breaker uses a drawout vertical mounting with motorized racking, enabling quick, safe insertion and removal without fully de-energizing the panel. It is suited for motor control centers and MCC feeders, supports standard panelboard footprints, and reduces maintenance time while improving operator safety during breaker swaps.
The MPSC6N4MEAXX2Q provides a 100 kA interrupting rating with a four-pole configuration. It incorporates the PXR25 LSIAM trip unit, delivering configurable protection settings and local/global coordination to protect feeders, motors, and critical loads from overcurrents and short circuits.
Yes. The four-pole, drawout design with motorized racking is explicitly intended for panel protection in motor control centers and industrial switchgear. Its ability to coordinate with PXRs and its compact, fan-cooled construction help fit MCCs where space and reliability are critical.
The unit is CE Marked, UL Listed, ANSI CSA Certified, with additional certifications including KEMA, Lloyd’s Register, ABS, and DNV GL. These certifications support global procurement, regulatory compliance, and safer acceptance in diverse markets.
Key benefits include motorized racking for faster maintenance, reduced arc exposure, and precise protection with the PXR25 unit, leading to fewer unplanned outages. The unit’s robust interrupt capacity and modular design also contribute to lower lifecycle costs by extending service intervals and simplifying upgrades in growing facilities.