Eaton MPSC6N4WEAXX2C Magnum low voltage power circuit breaker - UL Listed
Part Number: MPSC6N4WEAXX2C
Quick Summary
The Eaton Magnum low voltage power circuit breaker provides reliable overcurrent protection for switchgear and motor control centers. Engineers face nuisance trips and downtime when protection schemes aren’t aligned, and coordinating feeders can become a maintenance bottleneck. UL Listed, CE Marked, and CSA Certified help ensure regulatory compliance across global installations, while the PXR20 LSIG trip unit supports precise selective protection. With a drawout vertical mounting design, installation and maintenance are faster and safer, reducing commissioning time. In practice, this translates to lower total cost of ownership and improved system reliability for data centers, manufacturing lines, and large-scale power distribution.
Product Information
Extended Description
MPSC6N4WEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NNAABBCC), 100 kA, Four-pole, Drawout vertical mounting, PXR20 LSIG trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC6N4WEAXX2C
UPC
786689630423
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CCC Marked NEMA Compliant SABA Listed CE Marked
Certifications
KEMA Certified UL Listed ANSI Lloyd's Register Certified CSA Certified DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC6N4WEAXX2C
Eaton Specification Sheet - MPSC6N4WEAXX2C
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Cyber security white paper
Cyber security white paper
Cyber security white paper
The Magnum low voltage circuit breaker uses a four-pole design with a robust drawout vertical mounting, delivering balanced protection across phases for main feeders and MCCs. This feature translates to enhanced system reliability and easier preventive maintenance in demanding industrial environments. The PXR20 LSIG trip unit enables selective coordination, reducing nuisance trips and minimizing arc flash risk while enhancing fault isolation accuracy in large switchgear assemblies. In practice, you gain tighter protection strategies and faster restoration times after faults. The unit is rated for up to 100 kA short-circuit interruption with a 6000 A frame, providing confidence in heavy-duty distribution schemes and data-center backplanes where uptime matters. Compatibility with Magnum PX protection tools supports monitoring and integration with Power Xpert Protection Manager for centralized control. The drawout vertical mounting simplifies installation, replacements, and hot-swapping of breakers in crowded panels, cutting commissioning time and reducing labor costs. Certification across UL, CE, and CSA, plus additional standards, ensures procurement simplicity and global applicability, enabling standardized protections across multinational sites while meeting evolving regulatory requirements. The combination of rugged construction, modular trip units, and wide packaging compatibility helps borderline projects stay within budget by minimizing custom configurations and spare-parts inventories.
Get a Quick Quote for a Eaton MPSC6N4WEAXX2C
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC6N4WEAXX2C?
Enquire Now
FAQs
The MPSC6N4WEAXX2C uses a drawout vertical mounting design, standard for Magnum frames, enabling straightforward installation and rapid maintenance in crowded panels. This setup supports easy hot-swapping and fast isolation of faults without disassembling the panel, reducing downtime during routine inspections and replacements.
Key specs include a four-pole configuration with a PXR20 LSIG trip unit, 100 kA interrupting rating, and a 6000 A frame. Its physical dimensions are 16.3 in (depth) Ă— 16.8 in (height) Ă— 44.1 in (width), with a weight of 319 lb. These figures support robust protection in large switchgear and MCC applications.
Yes. The Magnum MPSC6N4WEAXX2C is designed for main and feeder protection in switchgear and motor control centers. Its four-pole format, LSIG trip unit, and drawout mounting provide selective protection and ease of maintenance in centralized distribution schemes common to MCCs and industrial switchgear assemblies.
This model carries UL Listed, CE Marked, and CSA Certified marks, with additional certifications such as ANSI and Lloyd’s Register. These certifications validate safety, performance, and compliance across regions, simplifying procurement for multinational projects and ensuring alignment with regulatory requirements for electrical distribution equipment.
The LSIG trip unit and drawout design minimize nuisance trips and streamline maintenance, reducing unscheduled downtime and facilitating fast part replacement. The combination of selective coordination, modular protection, and global certifications supports lower total cost of ownership through extended service life, easier spares planning, and faster commissioning in high-demand manufacturing and data-center environments.