Eaton MPSC6N4WEAXXSW Magnum low voltage power circuit breaker - UL Listed
Part Number: MPSC6N4WEAXXSW
Quick Summary
Eaton Magnum low voltage power circuit breaker is a four-pole protection device designed to safeguard industrial electrical distributions and switchgear. Engineers often struggle with downtime and maintenance bottlenecks when replacing aging breakers in crowded control panels. This model carries UL Listed, CSA Certified, and CE Marked approvals, along with NEMA compliance, delivering regulatory confidence across global installations. By pairing a robust 6000 A frame with 100 kA interrupting capacity and the option to upgrade with Power Xpert Release trip units, it supports scalable, cost-efficient power distribution while minimizing service interruptions.
Product Information
Extended Description
MPSC6N4WEAXXSW Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NNAABBCC), 100 kA, Four-pole, Drawout vertical mounting, No trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC6N4WEAXXSW
UPC
786689630409
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
SABA Listed CE Marked CCC Marked NEMA Compliant
Certifications
CSA Certified KEMA Certified Lloyd's Register Certified ANSI UL Listed ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC6N4WEAXXSW
Eaton Specification Sheet - MPSC6N4WEAXXSW
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Safer by design: arc energy reduction techniques
Safer by design: arc energy reduction techniques
Safer by design: arc energy reduction techniques
The four-pole design with a drawout vertical mounting delivers secure, service-friendly protection for multi-line loads, enabling rapid breaker replacement with minimal panel disruption and reduced downtime. This translates to faster maintenance cycles and lower on-site labor costs for industrial plants and data centers. With a 6000 A frame and 100 kA short-circuit capability, the Magnum unit provides strong fault tolerance for motor-start loads and high-inrush applications, improving overall system reliability. Although shipped without a trip unit, it is compatible with Power Xpert Release trip units for Magnum PXR breakers, enabling scalable protection and coordinated trip strategies across an installation. The fan-cooled cooling design maintains enclosure temperatures within spec in dense control rooms, supporting longer breaker life and stable performance under peak loads. Certifications including UL Listed, CSA Certified, CE Marked, and NEMA Compliant help you meet regional regulatory requirements with confidence, reducing audit risk and procurement complexity. Precise dimensions and substantial weight (16.3 in length, 16.8 in height, 44.1 in width, 319 lb) support accurate enclosure planning and stable mechanical integration within large electrical rooms and switchgear assemblies. In practice, engineers can rely on this Magnum model to simplify installation, streamline preventive maintenance, and extend service intervals in heavy-duty automation environments.
Get a Quick Quote for a Eaton MPSC6N4WEAXXSW
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC6N4WEAXXSW?
Enquire Now
FAQs
This unit ships without a trip unit, but it is compatible with Power Xpert Release trip units for Magnum PXR breakers. For upgrade paths, choose a PXR trip unit and verify enclosure space, wiring, and control signals to ensure proper coordination and alarms within your protection scheme.
The MPSC6N4WEAXXSW features a four-pole frame with a 6000 A frame rating and a 100 kA short-circuit current rating, suitable for large motor loads and high-inrush applications in industrial switchgear and control panels.
Yes. The unit carries UL Listed and CSA Certified marks, plus CE marking and NEMA compliance, providing broad regulatory compatibility for US, Canadian, and many international installations.
The breaker uses drawout vertical mounting and measures 16.3 in in length, 16.8 in in height, and 44.1 in in width, weighing 319 lb. Plan for enclosure space, clearance for insertion/removal, and access to the trip unit wiring if upgrading to PXR. Consider coupling with Power Xpert Protection Manager for monitoring.
The robust fan-cooled design and heavy-duty frame improve reliability in demanding environments, reducing unplanned downtime. The option to upgrade with PXR trip units enables coordinated protection and easier diagnostics, lowering maintenance costs over the life of the installation and improving overall asset utilization.