Eaton MV48M12F15CU General purpose Transformer - UL Listed

Part Number: MV48M12F15CU
Manufacturer
Eaton
Part number
MV48M12F15CU

Quick Summary

MV48M12F15CU is a general purpose ventilated transformer designed for three-phase power distribution in marine and industrial environments. Engineers often struggle with heat buildup, enclosure size, and regulatory compliance in harsh facilities. This unit is UL Listed, ABS Type Certified for marine duty, and housed in a NEMA 2 enclosure to withstand dust, moisture, and washdowns. It delivers a 15 kVA rating with copper windings, 60 Hz operation, and a 115°C rise, suitable for demanding control panels. With a 480 V primary and 120 V secondary, plus two voltage taps (+2.5% and -2.5%), installation is straightforward in standard frame footprints. The result is reliable power delivery, reduced maintenance, and lower lifecycle costs for industrial users.

Product Information

Extended Description

MV48M12F15CU Eaton: Eaton Marine Duty ABS Ventilated Transformer, Three-Phase, 480V Delta, 2@+2.5%, 4@-2.5%, 120V Delta, 115C Rise, 15 kVA, Copper windings, 60 Hz, NEMA 2
Product Name
Eaton General purpose ventilated transformer
Catalog Number
MV48M12F15CU
UPC
786680032349
Product Length/Depth
16.42 in
Product Height
29.99 in
Product Width
22.9 in
Product Weight
206 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Not Applicable
Certifications
UL Listed
Catalog Notes
ABS Type Certified
Coil material
Copper
Enclosure
NEMA 2
Frame
912D
Insulation
220 °C
Tap size
2 at +2.5%, 4at -2.5%
Type
DT-3M
Wiring connection
281B15M
Frequency rating
60 Hz
Kva Rating
15 kVA
Primary voltage
480 V
Secondary Voltage
120 V
Sound Level
NEMA ST-20
Temperature rise
115 °C rise
Volt ampere rating
15
Weathershield
WS38
Feature: 15 kVA rating combined with copper windings ensures high efficiency and robust load handling. Business Impact: Lower copper losses translate to cooler operation and energy savings over the life of the transformer. Application: Ideal for motor control centers and distribution panels in demanding environments. Feature: 60 Hz operation with precise voltage taps (2 at +2.5%, 4 at -2.5%). Business Impact: Fine voltage regulation under varying loads improves PLC and motor performance, reducing nuisance tripping. Application: Critical where supply stability affects process reliability and equipment lifespan. Feature: 480 V primary / 120 V secondary in a three-phase delta configuration. Business Impact: Simplified integration with typical plant wiring schemes and downstream equipment. Application: Common in industrial power distribution and marine panels. Feature: NEMA 2 enclosure with ABS Type Certified construction. Business Impact: Weather and washdown resistance support uptime in dirty or humid environments. Application: Fits indoor spaces and protected outdoor areas under standard installation practices. Feature: Temperature rise of 115°C and 912D frame footprint with 16.42 in length, 22.9 in width, 29.99 in height. Business Impact: Predictable thermal performance and easy mounting in existing rack systems, minimizing retrofit costs. Application: Panels, switchgear assemblies, and control cabinets in compact footprints. Feature: 281B15M wiring connection and listed certification set including UL Listed status. Business Impact: Streamlined field wiring and faster procurement with proven compliance. Application: OEM panel builds and service upgrades seeking dependable compliance and plug-and-play installation. Weathershield WS38 option and general reliability considerations further reduce maintenance overhead and extend service life in harsh industrial settings.

Get a Quick Quote for a Eaton MV48M12F15CU

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MV48M12F15CU? Enquire Now

FAQs

MV48M12F15CU is designed for indoor or protected indoor use in a NEMA 2 enclosure. Allow access for wiring, taps, and maintenance, and align with the 912D frame footprint. Common practice includes leaving clearance for cooling and serviceability, with attention to gate or door openings to accommodate the 206 lb weight. Follow standard Eaton mounting guidelines to ensure proper ventilation and code compliance.
The transformer provides taps at +2.5% and -2.5% to adjust the secondary voltage under load. This enables fine-tuning of output around 120 V during voltage fluctuations, helping sensitive equipment maintain performance. Use the 281B15M wiring connection per manufacturer guidelines and verify wiring changes with a qualified electrician to maintain UL and ABS compliance.
Yes. MV48M12F15CU is specified for marine duty with ABS Type Certification and a UL Listed rating, plus a rugged NEMA 2 enclosure. Its 115°C rise and copper windings support reliable operation in hot, damp, or washdown-prone spaces. For marine control panels, combining these certifications with the compact footprint simplifies regulatory clearance and installation.
MV48M12F15CU carries UL Listed certification and ABS Type Certification, indicating compliance with safety and marine industry requirements. These certifications simplify procurement and reduce risk during audits. The NEMA 2 enclosure adds environmental protection for dusty or moist environments, while copper windings and 60 Hz operation meet standard industrial expectations.
Maintenance needs are minimized by rugged construction, a 115°C rise limit, and high-quality copper windings, which reduce thermal stress and energy losses. ROI comes from improved reliability, reduced downtime, and lower replacement costs over a long service life. The unit’s standard frame and taps simplify installation, spare parts availability, and future upgrades.