Eaton MV48M28B12CUEE Transformer - 112.5 kVA

Part Number: MV48M28B12CUEE
Manufacturer
Eaton
Part number
MV48M28B12CUEE

Quick Summary

Eaton MV48M28B12CUEE is a general purpose ventilated transformer that powers marine and industrial distribution. Operators struggle with voltage stability and downtime in harsh marine environments, where loads swing and thermal stress challenges escalate maintenance. Certification scope varies; contact the manufacturer for CE, SIL, and IP-rated options as applicable. This solution supports 3-phase power systems and marine-duty workloads, delivering reliable output, voltage regulation, and lower maintenance costs for shipyards, offshore platforms, and on-board systems. Engineers benefit from adjustable taps and copper windings, enabling efficient, compliant deployment with existing switchgear. Procurement teams value durability and service life in corrosive environments while meeting industry standards.

Product Information

Extended Description

MV48M28B12CUEE Eaton: Eaton General purpose ventilated transformer, Marine-duty, DT-3 (3-phase), PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 208Y/120V, 80°C rise, 112.5 kVA, Copper windings, EE
Product Name
Eaton General purpose ventilated transformer
Catalog Number
MV48M28B12CUEE
UPC
786680140501
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Certifications
Contact Manufacturer
Primary voltage
480 V
Secondary Voltage
208 Y/120 V
Volt ampere rating
112.5 kVA
Feature: 3-phase 480 V primary to 208Y/120 V secondary with a 112.5 kVA rating. Business Impact: Enables robust power conversion for critical loads while maintaining voltage integrity under varying load conditions. Application: Shipboard electrical panels and offshore platform distribution where reliable step-down occurs without compromising safety. Feature: Marine-duty DT-3 design with an 80°C rise and ventilated cooling. Business Impact: Improves thermal performance in high ambient temperatures typical of vessels, reducing thermal overload risk and extending service life. Application: Engine rooms, weather decks, and other harsh marine environments. Feature: Copper windings. Business Impact: Delivers lower impedance and higher efficiency, translating to reduced I2R losses and cooler operation over the life of the asset. Application: Continuous duty installations on ships and industrial facilities seeking long-term energy savings. Feature: Tap changes (+2.5% and -2.5%). Business Impact: Provides voltage regulation to compensate for line fluctuations, improving equipment performance and protecting sensitive electronics. Application: Control panels, motors, and PLC loads in variable power networks. Feature: 208Y/120 V secondary. Business Impact: Matches common low-voltage distribution standards, simplifying panel design and component compatibility. Application: Instrumentation, control circuits, and auxiliary loads on vessels and industrial sites. Insight and context: For marine projects, selecting a ventilated, copper-wound transformer with programmable taps supports both regulatory compliance and operational efficiency, helping teams minimize downtime and maintenance spend while sustaining power quality across fluctuating loads.

Get a Quick Quote for a Eaton MV48M28B12CUEE

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MV48M28B12CUEE? Enquire Now

FAQs

For marine installations, ensure adequate clearance for ventilation, secure mounting to withstand vibration, and proper cable routing from 480 V input to the 208Y/120 V output. Verify enclosure suitability and environmental exposure without exceeding the 80°C rise rating. Plan for taps accessibility during commissioning to enable voltage adjustments in variable load conditions.
The 112.5 kVA rating defines maximum continuous load capability, supporting multiple drives and controls without overheating. The taps (+2.5% / -2.5%) allow fine voltage regulation to maintain stable downstream voltages, reducing nuisance trips and protecting sensitive equipment in fluctuating shipboard electrical environments.
Yes. With a 480 V primary and 208Y/120 V secondary, the transformer aligns with widely used offshore panel boards and low-voltage distribution circuits. Its copper windings offer low losses, while the ventilated design supports reliable operation in elevated ambient temperatures typical of marine facilities.
Certification scope for MV48M28B12CUEE varies by region and application; the listing indicates Certification contact with the manufacturer. To ensure compliance for your project, request current CE, SIL, and IP-rated options directly from Eaton and confirm needed marine approvals before procurement.
Copper windings reduce electrical losses and improve thermal performance, extending winding life and lowering operating temperatures. Ventilated cooling further mitigates heat buildup in high ambient environments, which can translate to fewer outages, lower maintenance costs, and a faster return on investment in demanding marine or industrial deployments.