The Eaton N29M28F75A K-Factor nonlinear ventilated transformer is designed to support high-availability power distribution in industrial facilities. Operators and engineers often contend with voltage swings and harmonic stress that jeopardize equipment uptime; this unit mitigates those risks with its K-13 design and advanced cooling. UL Listed safety certification is included, signifying rigorous safety compliance, while the three-phase 75 kVA rating and 208 V primary deliver reliable grid-to-load performance. By combining solid mechanical robustness with flexible tapping and shielded windings, it helps plants meet reliability targets while reducing maintenance costs and energy waste.
Product Information
Extended Description
N29M28F75A Eaton: K-Factor Non Linear Transformer, Ventilated, K-13, Three-phase, PV: 208V, Taps: 2 at +2.5% FCAN, 4 at -2.5% FCBN, SV: 208Y/120V, 115°C, 75 kVA , Al windings , Elec. Shield, Frame: 915D, uses WS39
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N29M28F75A
UPC
786680014598
Product Length/Depth
22 in
Product Height
39 in
Product Width
29 in
Product Weight
600 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Model A
Coil material
Aluminum
Type
Ventilated transformer
Design
K-13
Frame
915D
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
60 Hz
Kva Rating
75 kVA
Phase
Three-phase
Primary voltage
208 V
Secondary Voltage
208Y/120 V
Temperature rise
115 °C rise
Special features
Electrostatically Shielded
Weathershield
WS39
Commercial Distribution, Transformers, Volume 2, Tab 2
Eaton's Transformer Flex Center
Eaton Specification Sheet - N29M28F75A
Selling Policy 25-000 - Distribution and Control Products and Services
Feature → Business Impact → Application: K-Factor nonlinear design reduces harmonic amplification and improves voltage regulation, increasing system uptime and reducing panel stress in manufacturing lines and data centers. Application: Three-phase, 75 kVA rating at 60 Hz supports critical loads across process controls and facility distribution. Feature → Business Impact → Application: Ventilated cooling with Frame 915D enables lower temperature rise and better transient handling, improving reliability in hot electrical rooms and outdoor-rated installations. Application: Ideal for harsh environments where ambient temperatures and duty cycles are high. Feature → Business Impact → Application: Tap changes (2 at +2.5% FCAN, 4 at -2.5% FCBN) provide on-site voltage adjustment to compensate for line variance, reducing spare components and improving load performance in systems with long feeders. Application: Data centers, machine shops, and print/packaging lines requiring tight voltage control. Feature → Business Impact → Application: Aluminum windings and electrostatic shield reduce losses and EMI, supporting energy efficiency targets and safer installation near sensitive equipment. Application: Modern industrial facilities with mixed-load panels and strict EMI limits. Feature → Business Impact → Application: WS39 weathershield and UL listing simplify outdoor or semi-enclosed installations and compliance reviews, lowering risk during commissioning. Application: Outdoor transformers or equipment rooms with partial enclosure exposure. Feature → Business Impact → Application: 115°C temperature rise ensures robust operation under peak loads, improving short-term capacity planning and lifecycle reliability. Application: Peak demand events and emergency standby configurations in manufacturing and distribution centers.
Get a Quick Quote for a Eaton N29M28F75A
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton N29M28F75A?
Enquire Now
FAQs
The N29M28F75A is a three-phase 75 kVA transformer with a frame 915D and aluminum windings. It supports standard field connections suitable for typical electrical rooms and enclosures. For installation, ensure adequate clearances for ventilation and access to taps, and reference the WS39 weather shield if mounting outdoors or in semi-enclosed spaces.
The K-Factor nonlinear design addresses harmonic currents by providing enhanced regulation and reduced harmonic distortion at the point of common coupling. This results in cleaner voltage profiles for critical loads, less stress on downstream equipment, and improved overall efficiency in systems with non-linear loads such as VFDs and switching supplies.
Yes. The transformer combines a rugged ventilated design with an 115°C rise rating, three-phase 60 Hz operation, aluminum windings, and an electrostatic shield, making it suitable for data centers and harsh industrial environments where reliability and EMI control are priorities. WS39 weathershield further enhances outdoor or semi-exposed installations.
The N29M28F75A carries UL Listed certification, signifying compliance with recognized safety standards for electrical equipment. This eases commissioning and procurement, supports safety audits, and aligns with most facility and contractor safety requirements for industrial power distribution equipment.
Plan for periodic thermal checks, especially during peak loads, to monitor winding temperatures and ventilation performance. The unit's 115°C rise rating provides robust short-term capacity, while the WS39 shield and aluminum windings reduce cooling and corrosion concerns. Regular inspection of taps and enclosure integrity helps sustain performance and minimize unplanned downtime.