Eaton N29M28T75CU Transformer - K-Factor nonlinear

Manufacturer
Eaton
Part number
N29M28T75CU

Quick Summary

The Eaton K-Factor nonlinear ventilated transformer stabilizes three-phase power for industrial facilities. Engineers face voltage swings and harmonic distortions that threaten uptime, and this unit mitigates those risks with robust regulation and effective cooling. Certification expectations vary by region; common targets include CE, IP ratings, and SIL standards—verify exact approvals with the manufacturer. With a 75 kVA rating, copper windings, and 60 Hz operation, it provides precise regulation for 208 V primary and 208Y/120 V secondary, while the +2.5% / -2.5% taps support field voltage balance. The WS39 weather shield and electrostatic shielding further enhance reliability in harsh environments, delivering operational value and predictable ROI for your power infrastructure.

Product Information

Extended Description

N29M28T75CU Eaton: Eaton Nonlinear ventilated transformer KT-13 Three-phase 208 DELTA 2 at +2.5% FCAN 4 at -2.5% FCBN 208Y/120V 150°C 75 kVA Copper windings 915D 283A WS39 Electrostatically shielded 60 Hz
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N29M28T75CU
UPC
786680111785
Product Length/Depth
22 in
Product Height
39 in
Product Width
29 in
Product Weight
922 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
Contact Manufacturer
Coil material
Copper
Wiring connection
283A
Type
Nonlinear ventilated transformer
Design
KT-13
Frame
915D
Tap size
2 at +2.5% FCAN 4 at -2.5% FCBN
Frequency rating
60 Hz
Kva Rating
75 kVA
Phase
Three-phase
Primary voltage
208 V
Secondary Voltage
208Y/120 V
Temperature rise
150 °C rise
Special features
Electrostatically shielded
Weathershield
WS39
The K-Factor nonlinear ventilated design reduces harmonic distortion and improves load stability, delivering cleaner power to drives, controls, and sensitive sensors. This translates to fewer coolant or cooling system trips and longer equipment life, especially in variable loading scenarios found in motor control centers and process lines. In practice, you’ll see more consistent voltage during peak demands and less require corrective actions in the PLC and VFDs. With a 75 kVA three-phase rating and copper windings, the transformer delivers robust real power handling while minimizing copper losses and heat generation. The copper windings contribute to higher efficiency under typical loads and improved thermal performance during peak demand. This is beneficial for energy budgets and reduces cooling loads in plant rooms. Voltage regulation is supported by ± taps (+2.5% and -2.5%), enabling field balancing to maintain the secondary at the desired level as input conditions drift. This feature simplifies commissioning and reduces system downtime during load shifts. It also helps meet device tolerances in sensitive equipment like servers, drives, and instrumentation. Electrostatic shielding reduces capacitive coupling and EMI/RFI into adjacent equipment, helping to meet installation-specific regulatory requirements. The WS39 weather shield option enhances outdoor or harsh-environment resilience, enabling outdoor siting or rooftop installations without compromising performance. Together, shielding and ventilation contribute to lower enclosure maintenance over the system lifetime. Physical footprint and mounting considerations are straightforward: 22 inches long, 29 inches wide, 39 inches high on a 915D frame with a 922 pound weight. The weight and frame standardization simplify crane-lift planning and palletized deliveries, reducing installation risk. The combination of size, build quality, and reputable manufacturer support supports faster ROI through predictable maintenance intervals and service parts availability. From design to commissioning, you gain industry-aligned reliability with copper-wound, ventilated construction designed for 60 Hz operation and 208 V systems. This helps engineers meet power quality objectives, comply with internal standards, and reduce the total cost of ownership across equipment fleets.

Get a Quick Quote for a Eaton N29M28T75CU

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N29M28T75CU? Enquire Now

FAQs

Install by mounting the unit on a compatible frame (915D) and wiring the 208 V primary in delta to 208 V. Connect the secondary to 208Y/120 V circuits using the 283A wiring connection, then set the taps to +2.5% or -2.5% as needed for voltage balance. Ensure proper ventilation and account for the 922 lb weight during placement.
The N29M28T75CU delivers 75 kVA at 60 Hz with copper windings to minimize I2R losses. Its K-Factor nonlinear design reduces harmonic distortion, while the 150 °C rise rating supports rugged operation in demanding environments. Expect reliable voltage regulation from 208 V input to a stable 208Y/120 V secondary across typical industrial loads.
Yes. The transformer features electrostatic shielding to lower EMI/RFI intrusion into sensitive equipment and control circuits. The WS39 weather shield option supports outdoor installations, while copper windings and robust cooling help maintain stable performance under load fluctuations common in data centers and production lines.
Certification status should be confirmed with Eaton; typical industrial transformers target region-specific approvals such as CE, IP ratings, and SIL standards depending on the installation. Always request the latest Eaton specification sheet and factory certifications to ensure your panel and process meet regulatory requirements.
The unit measures 22 inches long, 29 inches wide, and 39 inches high, with a weight of 922 pounds. This footprint fits standard electrical rooms and UL-style enclosures, simplifying space planning and crane-assisted installation, while the 75 kVA rating supports scalable load growth and predictable long-term ROI.