Eaton N29R28F4916 K-Factor nonlinear transformer - DOE 2016

Part Number: N29R28F4916
Manufacturer
Eaton
Part number
N29R28F4916

Quick Summary

The K-Factor nonlinear ventilated transformer from Eaton delivers reliable 150 kVA power distribution for 208/208Y‑120 V three‑phase systems. Engineers wrestle with energy waste, heat, and compliance in large dry-type installations. UL Listed, DOE 2016 Efficient, and 10 CFR Part 431 alignment ensure regulatory readiness across facilities. With a rugged NEMA 2 enclosure and aluminum windings, it delivers dependable service, lower cooling energy, and long-term cost savings for manufacturing facilities and data centers.

Product Information

Extended Description

N29R28F4916 Eaton: Eaton K-Factor nonlinear ventilated transformer, Aluminum windings, NEMA 2, FR945, 60 Hz, 150 kVA , Three-phase, 208 Delta V, 208Y/120 Vac, NEMA ST-20, 1 at +5%, 2 at -5%, 115°C, 150 kVA, 208 Vac-208Y/120 Vac, WS62, 325A, DOE 2016
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N29R28F4916
UPC
786680220500
Product Length/Depth
33.5 in
Product Height
66.18 in
Product Width
42.18 in
Product Weight
2242 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
DOE2016 Efficient
Certifications
UL Listed
Catalog Notes
10 CFR Part 431 (2016) Efficient
Coil material
Aluminum
Enclosure
NEMA 2
Wiring connection
325A
Type
Energy-efficient ventilated transformer
Frame
FR945
Insulation
220 °C
Mounting
Floor or wall
Tap size
1 at +5%, 2 at -5%
Frequency rating
60 Hz
Kva Rating
150 kVA
Volt ampere rating
150 kVA
Phase
Three-phase
Primary voltage
208 V
Secondary Voltage
208Y/120 V
Sound Level
NEMA ST-20
Temperature rise
115 °C rise
Voltage rating
208-208Y/120V
Efficiency
10 CFR Part 431-2016 (DOE 2016)
Modification 1
Electrostatic shield
Special features
K-factor 13
Weathershield
WS62
DOE 2016 Efficient compliance and UL Listed rating ensure regulatory alignment and lower operating costs for dry-type distribution transformers. In practice, these certifications reduce compliance risk and simplify procurement for plant facilities and data centers. K-Factor 13 design supports nonlinear loads by reducing overheating and improving voltage stability. This is essential for facilities with VFDs and power supplies, enabling reliable operation of automation equipment. Capacity and voltages: 150 kVA, three-phase, 208 V primary and 208Y/120 V secondary, 60 Hz. The 1 at +5%, 2 at -5% taps enable on-site voltage tuning to match loading conditions across the plant. Rugged construction like aluminum windings, 220 °C insulation, FR945 frame, and NEMA 2 enclosure deliver durability in indoor environments. This combination supports longer service life while keeping installation lightweight and manageable. Protection and compatibility features such as WS62 weather shield, 325 A wiring connection, and floor or wall mounting facilitate quick integration into existing electrical rooms. These design choices reduce field modifications and optimize space usage on factory floors.

Get a Quick Quote for a Eaton N29R28F4916

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N29R28F4916? Enquire Now

FAQs

Plan for floor or wall mounting in indoor spaces. The unit uses a NEMA 2 enclosure with WS62 shield and a FR945 frame, so ensure adequate clearance around ventilation paths and service access. Verify compatibility with existing panels and available electrical room space to simplify integration.
The transformer is a 150 kVA, three-phase device with 208 V primary and 208Y/120 V secondary, rated at 60 Hz. It features aluminum windings, insulation rated to 220 °C, and voltage taps of 1 at +5% and 2 at -5%, supporting voltage regulation under load.
Yes. Its K-Factor 13 design specifically accommodates nonlinear loads, reducing overheating and stabilizing voltage in environments with drives and power supplies. DOE 2016 efficiency and UL safety support reliable operation in data centers and automated manufacturing settings.
It is UL Listed and DOE 2016 Efficient compliant, with catalog notes referencing 10 CFR Part 431 alignment. These certifications support safety, energy efficiency, and regulatory compliance across regulated facilities.
Expect energy savings from DOE 2016 efficiency, reduced cooling requirements due to improved ventilation, and long service life from a FR945 frame, aluminum windings, and WS62 shield. Maintenance is typically limited to periodic inspection and cleaning, with ROI driven by energy cost reductions and reliability.