Eaton N29R47F1216 Transformer - DOE 2016 Efficient
Part Number: N29R47F1216
Quick Summary
The Eaton N29R47F1216 transformer is a high-efficiency power transformer for three-phase distribution in industrial facilities. Engineers often grapple with wasted energy, overheating, and regulatory pressure to meet DOE 2016 efficiency targets under varying loads. With UL Listed certification and DOE 2016 Efficient compliance, it also aligns with 10 CFR Part 431 Efficient requirements. As a K-Factor nonlinear ventilated transformer with aluminum windings and a NEMA 2 enclosure, it supports reliable three-phase power distribution while helping facilities meet energy and regulatory goals.
Product Information
Extended Description
N29R47F1216 Eaton: Eaton K-Factor nonlinear ventilated transformer, Aluminum windings, NEMA 2, FR944, 60 Hz, 220C, 112.5 kVA, Three-Phase, 208 to 480Y/277, 115C rise, Shielded, DOE 2016, WS61, E0269A, K13
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N29R47F1216
UPC
786680244780
Product Length/Depth
33.5 in
Product Height
60 in
Product Width
38 in
Product Weight
1275 lb
Compliances
DOE2016 Efficient
Certifications
UL Listed
Catalog Notes
10 CFR Part 431 (2016) Efficient
Coil material
Aluminum
Enclosure
NEMA 2
Wiring connection
E0269A
Type
Energy-efficient ventilated transformer
Frame
944
Insulation
220 °C
Mounting
Floor
Tap size
2 at +2.5%, 4at -2.5%
Frequency rating
60 Hz
Kva Rating
112.50 kVA
Volt ampere rating
112.50 kVA
Phase
Three-phase
Primary voltage
208 V
Secondary Voltage
480Y/277 V
Sound Level
NEMA ST-20
Temperature rise
115 °C rise
Efficiency
10 CFR Part 431-2016 (DOE 2016)
Modification 1
Electrostatic shield
Special features
K-factor 13
Weathershield
WS61
The N29R47F1216 uses a K-Factor nonlinear ventilated design, engineered to manage nonlinear harmonic currents in demanding loads. This translates into cooler operation, lower stray losses, and extended insulation life, reducing maintenance intervals. In practice, it suits motor drives, robotic cells, and critical control panels where voltage cleanliness and reliable cooling matter most. Aluminum windings deliver a robust balance of conductivity and weight, offering corrosion resistance and cost benefits in large installations. This design supports easier installation and long-term reliability in manufacturing floors and processing lines, helping facilities optimize total cost of ownership. DOE 2016 Efficient compliance aligns energy performance with regulatory expectations, supporting significant energy-cost savings across the facility while confirming regulatory alignment. UL Listed certification provides safety assurance for electrical assemblies, and compliance with 10 CFR Part 431 Efficient standards reinforces federal efficiency requirements for stationary transformers. The NEMA 2 enclosure, floor-mount design, and E0269A wiring connection simplify site installation and service access, reducing commissioning time and ongoing maintenance complexity. Electrostatic shielding and the WS61 Weathershield option further minimize EMI exposure and environmental impact, enabling stable operation in dusty or humid industrial spaces. This combination of features delivers a durable, compliant, and easy-to-service power distribution solution for demanding facilities.
Get a Quick Quote for a Eaton N29R47F1216
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton N29R47F1216?
Enquire Now
FAQs
The N29R47F1216 utilizes the E0269A wiring connection in a three-phase configuration and is floor-mountable in a NEMA 2 enclosure. Plan for proper clearance and access to the primary 208 V and secondary 480Y/277 V windings. Align with your Eaton panel or switchgear, connect shielded conductors where specified, and ensure consistent grounding and protection hardware for safe, compliant operation.
K-Factor 13 indicates robust performance under nonlinear loading, reducing harmonic heating and improving efficiency. The electrostatic shield minimizes EMI between windings, enhancing voltage stability and signal integrity for sensitive equipment. Together, they reduce stray losses, extend insulation life, and improve reliability in drives, controls, and mixed-load environments typical of manufacturing facilities.
Yes. With a 112.5 kVA rating, 60 Hz operation, and a 208 V to 480Y/277 V primary/secondary range, this unit supports diverse distribution needs in both manufacturing floors and data-center-adjacent environments. The NEMA 2 enclosure and rugged design offer dependable service in standard industrial spaces, while the electrostatic shield helps maintain clean power for critical equipment.
This transformer is UL Listed and complies with DOE 2016 Efficient standards. It also references 10 CFR Part 431 Efficient requirements for stationary transformers. These certifications ensure safety, energy performance, and regulatory alignment for industrial deployment and long-term operational governance.
Expect energy-cost savings from DOE 2016 Efficient performance and reduced maintenance due to robust construction, electrostatic shielding, and a sealed NEMA 2 enclosure. The 115 °C rise rating supports reliable operation under load, while floor mounting and accessible wiring connections simplify routine inspections. Over time, this can yield lower energy bills and longer service life for mid-to-large-scale distribution needs.