Eaton N2LPSM212220 UX71SDHAZ Light-Pak - Class I, Div 2
Part Number: N2LPSM212220 UX71SDHAZ
Quick Summary
Eaton Crouse-Hinds Light-Pak N2LPS emergency lighting system provides reliable exit-path illumination for hazardous-location facilities. In these environments, uptime and battery reliability are critical, and installation complexity often introduces risk. This system meets NEC/CEC standards, carries Class I, Division 2 hazardous location rating, and a NEMA 4 enclosure for rugged operations. The LED design, 12 Vdc output, and 120–277 VAC input simplify retrofit and ongoing maintenance, helping facilities reduce downtime and service costs while maintaining code compliance. Designed for easy field installation, it leverages Krydon fiberglass-reinforced polyester for chemical resistance and a compact footprint (5.56 in depth, 25.46 in height, 14.91 in width). With red letter visibility and minimal components (no lamp heads), it supports lower maintenance and predictable, compliant performance across industrial sites.
Product Information
Extended Description
N2LPSM212220 UX71SDHAZ Eaton: Eaton Crouse-Hinds series Light-Pak N2LPS emergency lighting system, 50/60 Hz, 120-277 Vac input voltage, LED, Red letter color, Krydon fiberglass-reinforced polyester, No lamp heads, Single sided, 12 Vdc output voltage, 6W
Product Name
Eaton Crouse-Hinds series Light-Pak N2LPS emergency lighting system
Catalog Number
N2LPSM212220 UX71SDHAZ
UPC
662276806948
Product Length/Depth
5.56 in
Product Height
25.46 in
Product Width
14.91 in
Product Weight
18 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2
NEMA Rating
4
Lamp type
LED
Wattage
6W
Number of lamp heads
None
Number of sides
Single Sided
Input voltage
120-277 Vac
Output voltage
12 Vdc
Frequency rating
50/60 Hz
Voltage rating
12 Vdc
Letter color
Red
Material
Krydon fiberglass-reinforced polyester
Crouse-Hinds series Global LED lighting portfolio
Crouse-Hinds series Global LED lighting portfolio
Crouse-Hinds series Light-Pak N2LPS LED Emergency Lighting System catalog page
Light-Pak N2LPS LED Emergency Lighting System Canadian certification
Light-Pak N2LPS LED Emergency Lighting System Canadian certification
Light-Pak N2LPS LED Emergency Lighting System Canadian certification
IF 1854 - N2LPS LED Emergency Lighting System - K57
IF 1854 - N2LPS LED Emergency Lighting System - K57
Eaton Specification Sheet - N2LPSM212220 UX71SDHAZ
Feature LED light source with 6W wattage → Business Impact Energy efficiency and long LED life reduce operating costs and maintenance cycles. Application Ideal for hazard-prone facilities seeking reliable illumination during outages and compliant egress paths. Feature Wide input range 120–277 VAC, 50/60 Hz and 12 VDC output → Business Impact Flexible power compatibility and stable emergency operation, enabling easy integration with existing electrical infrastructure. Application Retrofit projects across plants with varying main voltages while preserving consistent egress lighting standards. Feature Krydon fiberglass-reinforced polyester enclosure with red LED lettering and single-sided design → Business Impact Superior durability in harsh environments and high visibility without copper corrosion risk; supports straightforward mounting in confined spaces. Application Hazardous or classified locations requiring rugged, weather-resistant enclosures and clear egress indication. Feature No lamp heads and compact dimensions (5.56 in depth, 25.46 in height, 14.91 in width) → Business Impact Reduced parts inventory and maintenance downtime; simplified installation and service planning. Application OEMs and integrators deploying slimline emergency kits in constrained electrical rooms. Feature NEC/CEC compliance with Class I, Division 2 rating and NEMA 4 enclosure → Business Impact Regulatory assurance and environmental protection translate to lower risk, faster approvals, and fewer field reworks. Application Projects in oil, gas, chemical, and other hazardous workplaces demanding robust, certified emergency lighting. Feature 12 Vdc output with 6W LED and red letter color → Business Impact Enhanced egress visibility and predictable performance during power loss; supports standard signage compliance. Application Facilities that require clear, certified exit indicators for safe evacuation.
Get a Quick Quote for a Eaton N2LPSM212220 UX71SDHAZ
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton N2LPSM212220 UX71SDHAZ?
Enquire Now
FAQs
The N2LPSM212220 UX71SDHAZ is designed for 120–277 VAC input with a 12 VDC output, supporting 50/60 Hz operation. Its Krydon enclosure and single-sided footprint simplify mounting in restricted spaces while maintaining Class I, Division 2 compliance. Integration steps include verifying power availability, selecting a suitable mounting location, and reviewing installation sheets (IF1854) to ensure proper wiring and code adherence.
Key specs include a 6W LED lamp type, 12 VDC output, and an input range of 120–277 VAC at 50/60 Hz. The unit uses red exit lettering and is built from Krydon fiberglass-reinforced polyester, designed for reliability in hazardous locations. With no lamp heads, the device focuses on core emergency illumination while minimizing maintenance.
Yes. The N2LPS is rated for Hazardous/Classified Locations with NEC/CEC compliance and a Class I, Division 2 hazardous rating, plus a NEMA 4 enclosure. It is specifically intended for hazardous locations where durable construction and reliable LED emergency lighting are required to maintain safe egress during power outages.
The system meets NEC/CEC standards and carries a Class I, Division 2 rating, along with a NEMA 4 enclosure. UL-based Canadian certifications are documented in the provided files, ensuring compliance for installations in North American hazardous locations. This supports faster approvals and reduces certification-related delays.
The 6W LED design delivers long life with low energy consumption, reducing replacement lamps and associated labor. The absence of lamp heads lowers parts inventory, while the rugged Krydon enclosure improves durability in harsh environments. Together, these factors shorten maintenance windows and lower total cost of ownership in hazardous-location facilities.