Eaton N2LPSM212222 Light-Pak Emergency Lighting System - 4X Rated
Part Number: N2LPSM212222
Quick Summary
The Eaton Light-Pak N2LPS emergency lighting system delivers reliable illumination for hazardous environments. In hazardous locations, downtime and noncompliance with safety codes can drive costly outages and safety risks. It carries NEC/CEC certifications with Class I, Division 2 and Zone 2 ratings and a rugged NEMA 4X enclosure. Designed for 50/60 Hz operation from 120-277 Vac input with a 12 Vdc output and two LED lamp heads, it combines energy efficiency with dependable performance. This layout supports fast commissioning and reduced maintenance in industrial facilities, mining, and chemical processing.
Product Information
Extended Description
N2LPSM212222 Eaton: Eaton Crouse-Hinds series Light-Pak N2LPS emergency lighting system, 50/60 Hz, 120-277 Vac input voltage, LED, Krydon fiberglass-reinforced polyester, 2 lamp heads, 12 Vdc output voltage, 28W
Product Name
Eaton Crouse-Hinds series Light-Pak N2LPS emergency lighting system
Catalog Number
N2LPSM212222
UPC
662276806665
Product Length/Depth
5.56 in
Product Height
13.23 in
Product Width
10.52 in
Product Weight
12 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 2 Class I, Zone 2
NEMA Rating
4X
Lamp type
LED
Wattage
28W
Number of lamp heads
2
Input voltage
120-277 Vac
Output voltage
12 Vdc
Frequency rating
50/60 Hz
Voltage rating
12 Vdc
Material
Krydon fiberglass-reinforced polyester
Light-Pak N2LPSM2 LED Emergency Lighting System brochure
Light-Pak N2LPSM2 LED Emergency Lighting System brochure
Crouse-Hinds series Light-Pak N2LPS LED Emergency Lighting System catalog page
Light-Pak N2LPS LED Emergency Lighting System Canadian certification
Light-Pak N2LPS LED Emergency Lighting System Canadian certification
Light-Pak N2LPS LED Emergency Lighting System Canadian certification
IF 1853 - N2LPS LED Emergency Lighting System
IF 1853 - N2LPS LED Emergency Lighting System
Eaton Specification Sheet - N2LPSM212222
LED-based lighting delivers a compact 28W load with two lamp heads, reducing energy consumption while maintaining emergency visibility. This translates to lower energy costs and longer component life, particularly in continuously operating facilities where lamp failures disrupt production. The system’s 120-277 Vac input range and 50/60 Hz compatibility simplify integration across global sites, streamlining procurement and installation for mixed voltage plants. Krydon fiberglass-reinforced polyester housing provides rugged protection against chemicals, moisture, and impact, extending service life and reducing replacement costs in harsh environments such as chemical plants and offshore facilities. A NEMA 4X enclosure adds corrosion and water resistance, supporting outdoor, washdown, and high-dust locations while maintaining performance and safety. Hazardous location certifications including NEC Class I Division 2, Class II Division 2, and Zone 2, combined with NEC/CEC standards, simplify regulatory compliance audits and improve risk management. Two LED lamp heads offer redundancy, ensuring exit paths stay illuminated during a power outage, which translates to higher uptime and lower maintenance in safety-critical spaces.
Get a Quick Quote for a Eaton N2LPSM212222
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton N2LPSM212222?
Enquire Now
FAQs
Installation in hazardous locations requires following the NEC Class I Division 2, Class II Division 2, and Zone 2 guidelines, along with the system's NEMA 4X enclosure handling. The N2LPSM212222 is designed for durable mounting in industrial spaces; ensure sturdy wall or ceiling mounting as recommended by Eaton installation sheets. Confirm compatibility with existing wiring practices and secure ingress protection to maintain the integrity of the hazardous-location rating during retrofit or new installs.
Key specs include 28W LED lamp power, input voltage 120-277 Vac, output voltage 12 Vdc, and a frequency rating of 50/60 Hz. The system features two lamp heads and a Krydon housing. This combination supports reliable emergency illumination while allowing seamless integration with standard AC-powered emergency circuits across global facilities.
Yes. The N2LPSM212222 is certified for hazardous locations, including Class I Division 2 and Zone 2 environments, and is housed in a NEMA 4X enclosure. These ratings make it suitable for oil and gas facilities, petrochemical processing, and similar installations where hazardous atmospheres require compliant emergency lighting.
The system adheres to NEC/CEC standards and offers NEC hazardous location ratings for Class I Division 2, Class II Division 2, and Zone 2, along with a NEMA 4X enclosure. Canadian certifications are referenced in Eaton literature, and UL-listed documentation is available in the product literature package, supporting regulatory audits and global deployments.
Maintenance is reduced through LED reliability and lower power consumption, with a 28W load and two lamp heads that provide redundancy for critical exit paths. The 12 Vdc output supports efficient operation, while the rugged Krydon housing and 4X enclosure minimize replacement costs in harsh environments. Overall, expect improved uptime, lower energy costs, and faster payback in facilities with frequent hazardous-location outages.