Eaton N38M28F30CSCUEELS42 Transformer - KT-13 30 kVA
Part Number: N38M28F30CSCUEELS42
Quick Summary
Eaton N38M28F30CSCUEELS42 Transformer is a three-phase K-Factor nonlinear transformer designed for industrial power distribution in control panels, facilities, and data centers. Power reliability is often challenged by voltage drift and harmonic distortion from nonlinear loads, leading to trips and downtime; this solution helps manage those issues with a robust design and configurable taps. For compliance, verify relevant certifications such as SIL, CE, and IP ratings with the manufacturer, as requirements vary by region and application. With a 30 kVA rating, copper windings, a 380 V primary and 208Y/120 V secondary, plus adjustable taps, it delivers reliable, efficient power delivery and straightforward integration into existing Eaton-based architectures. The product is engineered for rugged environments, supporting easy maintenance and scalable deployments in modern factories.
Product Information
Extended Description
N38M28F30CSCUEELS42 Eaton: Eaton K-Factor nonlinear ventilated transformer, KT-13 (3-phase), PV 380V, Taps: 2 at +2.5% /4 at -2.5%, SV 208Y/120V, 115°C rise, 30 kVA, CS, Copper windings, EELS42
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N38M28F30CSCUEELS42
UPC
786680140730
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Certifications
Contact Manufacturer
Volt ampere rating
30 kVA
Primary voltage
380 V
Secondary Voltage
208 Y/120 V
Commercial Distribution, Transformers, Volume 2, Tab 2
Eaton's Transformer Flex Center
Eaton Specification Sheet - N38M28F30CSCUEELS42
The N38M28F30CSCUEELS42 uses a K-Factor nonlinear transformer design to mitigate harmonic currents from nonlinear loads, delivering improved system stability, reduced heat buildup, and extended equipment life. This translates to lower maintenance costs and fewer unplanned outages in critical production lines and data-center support systems. Its three-phase KT-13 configuration supports balanced power distribution across demanding industrial applications, enabling consistent performance for machine control panels and distribution centers. With a 380 V primary and 208Y/120 V secondary, it aligns with common industrial power architectures, simplifying integration into existing switchgear and panelboards while avoiding costly rework. Adjustable taps at +2.5% and -2.5% allow precise voltage regulation to compensate for feeder variations, enhancing protection for sensitive loads and reducing misoperation risk. Copper windings provide high conductivity, durability, and lower winding resistance under load, contributing to improved efficiency and lifespan in harsh environments. Ventilated cooling enables a 115°C rise rating, supporting sustained operation in rooms with modest ambient cooling and helping avoid derating in peak loads. The combination of robust construction, coil quality, and thermal margin makes installation straightforward in Eaton ecosystems and compatible with the Transformer Flex Center approach for modular, scalable deployment across growing facilities.
Get a Quick Quote for a Eaton N38M28F30CSCUEELS42
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton N38M28F30CSCUEELS42?
Enquire Now
FAQs
Verify that the site voltage sits within tolerance for 380 V primary and 208Y/120 V secondary operation. Check that panelboards and switchgear are rated for three-phase service and that the installation allows the unit’s 115°C rise with proper ventilation. Confirm tap settings (+2.5% / -2.5%) match the feeder voltage profile and that copper windings are compatible with your current wiring practices. Finally, ensure any required regional certifications are in place before commissioning.
The K-Factor nonlinear design targets harmonic currents from non-linear loads, reducing peak heating and voltage distortion. This improves voltage regulation, lowers the risk of nuisance trips, and enhances overall reliability for drives, PLCs, and other high-harmonic equipment. In practice, you’ll see steadier output under load variations, enabling tighter process control and longer asset life.
Yes. The N38M28F30CSCUEELS42 is designed for industrial power distribution with a 30 kVA rating and 380 V to 208Y/120 V output, making it compatible with typical data-center and manufacturing ancillary loads. Its copper windings, ventilated cooling, and adjustable taps support reliable operation under varying loads and ambient temperatures, while providing stable voltages essential for sensitive equipment.
Certifications can vary by region and application. The product notes indicate to confirm with the manufacturer, and typical checks include CE for European compliance, SIL ratings for safety-critical installations, and IP ratings for environmental protection. Always align with local electrical codes and industry standards before installation to ensure full regulatory compliance.
Expected ROI comes from improved reliability, reduced downtime, and lower energy losses from efficient copper windings and stable operation under harmonic loads. Maintenance is straightforward: monitor thermal performance, verify tap accuracy during periodic testing, and ensure adequate ventilation to sustain the 115°C rise rating. Regularly review harmonics and load profiles to optimize transformer life and reduce lifecycle costs.