Eaton N39G28T10XCU K-Factor nonlinear ventilated transformer - K13 XFMR

Part Number: N39G28T10XCU
Manufacturer
Eaton
Part number
N39G28T10XCU

Quick Summary

Eaton K-Factor nonlinear ventilated transformer delivers reliable 10 kVA three-phase power for 400-208Y/120V industrial systems. Operators and engineers need equipment that tolerates harmonic loads, minimizes heat, and fits standard footprint without complicated cooling. Certifications for this model are coordinated through the manufacturer, specifying performance criteria that align with demanding electrical environments. The N39G28T10XCU emphasizes copper windings, a 150°C rise rating, and a ventilated design that improves thermal performance under high-duty cycles. This enables safer operation in automation panels, manufacturing lines, and data centers, while reducing cooling energy and maintenance costs. The product supports Eaton's broader power management and distribution ecosystem, helping teams achieve reliable distribution and easier installation in retrofit or new-build projects.

Product Information

Extended Description

N39G28T10XCU Eaton: Eaton K-Factor nonlinear ventilated transformer 10 KVA K13 XFMR 3PH 400-208Y/120 150C RISE COPPER
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N39G28T10XCU
UPC
786680140587
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
255 lb
Certifications
Contact Manufacturer
Type
Ventilated transformer
Feature: K-Factor nonlinear ventilated design actively manages harmonic currents, reducing overheating risk and extending transformer life. Business impact: improved reliability and lower maintenance costs in high-harmonic environments typical of modern automation panels and processing lines. Application: automation cells, CNC equipment, and process lines where power quality matters. Feature: 10 kVA rating with three-phase 400-208Y/120V capability enables scalable power distribution from standard utility voltages. Business impact: faster panel integration, reduced need for oversized hardware, and smoother startup of equipment. Application: machine control centers and industrial automation cabinets. Feature: Copper windings and a 150°C rise rating deliver robust electrical performance under continuous duty. Business impact: enhanced overload tolerance and higher thermal margins, limiting voltage dips during peak loads. Application: manufacturing lines and data centers with sustained demand. Feature: Ventilated design enhances cooling efficiency beyond sealed units, lowering ambient temperature rise in the enclosure. Business impact: lower cooling energy use and longer MTBF. Application: automation cabinets in space-limited facilities. Feature: Durable construction at 255 lb with compatibility to Eaton’s low-voltage distribution catalog and standard mounting schemes. Business impact: easier site integration, faster installation, safer handling. Application: retrofit and new-build projects in industrial plants with validated specs. Feature: Comprehensive documentation including datasheets and catalogs, such as Commercial Distribution, Transformers Volume 2, Tab 2, and a dedicated specification sheet. Business impact: accelerates procurement and ensures precise configuration, reducing risk of mismatched components. Application: engineering and procurement teams seeking verifiable specs.

Get a Quick Quote for a Eaton N39G28T10XCU

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N39G28T10XCU? Enquire Now

FAQs

The N39G28T10XCU is a 3-phase, 10 kVA transformer configured for 400-208Y/120V service. It supports standard LV distribution practices and integrates with Eaton's low-voltage catalog for straightforward panel mounting. For best results, ensure enclosure clearance for ventilation and verify secondary connections align with your panel schedule.
K-Factor nonlinear design targets harmonic currents by shaping the transformer response, reducing excessive heating and improving load stability. This is crucial in modern facilities with nonlinear loads such as variable-frequency drives and programmableControllers, where maintaining voltage quality and transformer life can lower maintenance and energy costs.
Yes. With a 10 kVA rating and a 400-208Y/120V secondary, it fits common automation and IT-related power requirements. Its ventilated, copper-wound construction provides better thermal performance under continuous loads typical of data centers and machine control centers, helping maintain uptime and efficiency.
Certifications for this model are coordinated through the manufacturer. For regulatory alignment, request the latest specification sheet from Eaton to confirm CE, SIL, IP ratings, and any site-specific compliance details relevant to your installation.
The combination of improved harmonic handling, higher thermal margins, and ventilated cooling reduces cooling energy and maintenance needs. This can translate to lower total cost of ownership over the life of the installation, especially in environments with high harmonic content and duty cycles.