Eaton N39M28T75XCU K-Factor Transformer - UL Listed

Part Number: N39M28T75XCU
Manufacturer
Eaton
Part number
N39M28T75XCU

Quick Summary

N39M28T75XCU is an Eaton K-Factor nonlinear ventilated transformer delivering reliable three-phase power for industrial automation and distribution. Engineers often struggle with voltage instability, heat buildup, and rising maintenance costs when transformers operate at high loads. UL Listed certification supports safe North American installations and consistent performance across critical equipment. The model combines rugged copper windings with adjustable taps and a 75 kVA rating to improve efficiency, reliability, and total lifecycle cost for modern facilities.

Product Information

Extended Description

N39M28T75XCU Eaton: K-Factor nonlinear ventilated transformer K-13, Three-phase, PV: 400V, Taps: 2 at 0.025 FCAN, 4 at -0.025 FCBN, SV: 208Y/120V, 150°C, 75 kVA, Cu windings, Elec. Shield, Frame: 916A
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N39M28T75XCU
UPC
786680080579
Product Length/Depth
23.42 in
Product Height
48.56 in
Product Width
28.22 in
Product Weight
888 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Coil material
Copper
Type
Ventilated transformer
Design
K-13
Frame
916A
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
50-60 Hz
Kva Rating
75 kVA
Phase
Three-phase
Primary voltage
400 V
Secondary Voltage
208Y/120 V
Temperature rise
150 °C rise
Special features
Electrostatically Shielded
Weathershield
WS19
Feature: K-Factor nonlinear design helps manage harmonic currents and reduces transformer overheating, delivering improved reliability in high-load environments. Business Impact: Lower heat in electrical rooms translates to longer equipment life and reduced cooling costs. Application: Data centers, manufacturing lines, and process facilities benefit from stable voltages under harmonic-rich loads. Feature: Copper windings and electrostatic shielding minimize core and copper losses while reducing EMI, enabling smoother operation of sensitive drives. Business Impact: Improved efficiency and EMI compliance, lowering energy waste and shielding adjacent equipment. Application: Automation panels and motor control centers on factory floors. Feature: Tap size options—2 at +2.5% FCAN and 4 at -2.5% FCBN—offer voltage flexibility for fluctuating supply conditions. Business Impact: Faster commissioning and tighter voltage control across loads. Application: Panelboards and distribution centers serving mixed-voltage equipment. Feature: 75 kVA, 400 V primary, 208Y/120 V secondary in a 3-phase, 50-60 Hz system aligns with standard industrial architectures. Business Impact: Simplified integration with existing standards reduces design risk and procurement complexity. Application: Industrial automation, machine shops, and data centers require consistent secondary voltages. Feature: Weather shield WS19, rugged frame 916A, and 150 °C rise tolerance support harsh environments and long service life. Business Impact: Lower maintenance intervals and higher uptime. Application: Outdoor cabinets, exposed facilities, and manufacturing floors with elevated ambient temperatures.

Get a Quick Quote for a Eaton N39M28T75XCU

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N39M28T75XCU? Enquire Now

FAQs

Ensure correct voltage class (400 V primary, 208Y/120 V secondary), verify panel clearance for the 28.22 in width and 48.56 in height, and follow UL-listed installation guidelines. Use proper shielded grounding and install the WS19 weather shield when applicable to protect from environmental exposure.
Three-phase configuration at 50-60 Hz, 75 kVA rating, 400 V primary, 208Y/120 V secondary, copper windings, frame 916A, and taps at +2.5% FCAN and -2.5% FCBN, with 150 °C rise for thermal tolerance.
Yes. The K-Factor nonlinear design is built to mitigate harmonic currents, reducing overheating and maintaining voltage quality in equipment such as drives and PLCs, while enabling reliable operation under heavy loading.
This model is UL Listed, indicating compliance with North American electrical safety standards. Certification supports safer installation, easier approvals in regulated environments, and alignment with procurement specifications for industrial facilities.
The combination of copper windings, effective heat management, and robust weather shielding reduces energy losses and downtime. This leads to lower maintenance costs and longer service life in demanding applications.