Eaton N43M28B33XCSCU K-Factor Transformer - UL Listed

Part Number: N43M28B33XCSCU
Manufacturer
Eaton
Part number
N43M28B33XCSCU

Quick Summary

Eaton K-Factor nonlinear ventilated transformer supplies conditioned power for three-phase industrial panels, delivering clean, stable voltage to critical equipment. This design helps minimize voltage fluctuation and heat in environments where uptime and reliability are non-negotiable. UL Listed safety certification accompanies rugged copper windings and the K-13 design, ensuring reliability in harsh manufacturing settings. With a 416 V primary and 208Y/120 V secondary, 50/60 Hz compatibility, and a 300 kVA rating, it supports efficient distribution in tight electrical rooms while enabling straightforward installation and consistent downstream performance. Designed for retrofit alongside existing power management systems, it reduces wiring complexity and supports scalable automation.

Product Information

Extended Description

N43M28B33XCSCU Eaton: Eaton K-Factor nonlinear ventilated transformer, 300kVA,Non-LinearK-13 Vent XFMR 3PH 416 Delta-208Y/120, 50/60Hz, 2 at+2.5%, 4 at-2.5%, 80C Rise, Cu shield, Cu
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N43M28B33XCSCU
UPC
786689413545
Product Length/Depth
32 in
Product Height
66 in
Product Width
50 in
Product Weight
3000 lb
Certifications
UL Listed
Coil material
Copper
Design
K-13
Tap size
2 at+2.5%, 4 at-2.5%
Frequency rating
50-60 Hz
Kva Rating
300 kVA
Phase
Three-phase
Primary voltage
416 V
Secondary Voltage
208Y/120 V
Temperature rise
80 °C rise
Feature: K-Factor nonlinear ventilated design; Business Impact: improves harmonic handling and heat management, reducing system losses and extending transformer life; Application: suitable for factory floors with dense automation equipment. This translates to fewer outages and lower cooling requirements in control rooms. Feature: Copper windings and copper shield; Business Impact: enhances conductivity and fault tolerance, delivering lower impedance and more predictable performance; Application: critical load centers and machine interfaces where voltage stability matters. Feature: Tap changer with 2 at +2.5% and 4 at -2.5%; Business Impact: enables on-site voltage regulation under load swings, minimizing downstream equipment stress; Application: distribution panels powering motors and drives. Feature: 80°C temperature rise rating; Business Impact: higher loading capability in compact footprints, reducing footprint and capital cost; Application: tight electrical rooms in automation plants. Feature: Three-phase 416 V to 208Y/120 V; Business Impact: matches common industrial power systems, speeding installation and ensuring compatibility; Application: machine control centers and panel boards. Feature: UL Listed certification; Business Impact: supports procurement compliance and reduces risk in regulatory audits; Application: enterprise-scale manufacturing environments. Feature: Dimensions and weight (32 in L x 50 in W x 66 in H; 3000 lb); Business Impact: informs installation planning and structural support requirements; Application: retrofit projects and new installations alike.

Get a Quick Quote for a Eaton N43M28B33XCSCU

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N43M28B33XCSCU? Enquire Now

FAQs

The transformer is three-phase with a 416 V primary and 208Y/120 V secondary. Plan for a ventilated, accessible location with adequate clearance and a solid mounting base to support its 3000 lb weight. Use the tap settings (+2.5% and -2.5%) to regulate voltage under load, ensure proper wiring to 50/60 Hz supplies, and provide appropriate overcurrent protection and shielded copper conductors.
K-Factor nonlinear design targets harmonic currents produced by modern drives and loads, reducing waveform distortion and heat buildup. This results in lower plate and insulation stress, improved efficiency, and longer equipment life. In practical terms, expect more stable bus voltages, reduced cooling requirements, and fewer unplanned outages in automation labs and production lines.
Yes. With 300 kVA capacity, three-phase operation, and a 416 V to 208Y/120 V output, the N43M28B33XCSCU is well-muited for machine control panels and distribution boards. The copper windings offer low impedance, aiding voltage regulation for sensitive drives, PLCs, and sensors. Its UL Listed status supports compliance in regulated manufacturing environments and simplifies procurement.
This model is UL Listed, providing recognized safety certification for industrial electrical equipment. While UL Listed handles safety compliance, verify site-specific requirements for CE marking or IP ratings if applicable to your region or enclosure standards. The combination of UL safety certification and rugged design supports reliable operation in harsh manufacturing environments.
The transformer’s high efficiency, reduced thermal stress from the ventilated design, and robust copper windings contribute to lower energy losses and cooler operation. The 80°C rise rating enables greater loading density, potentially reducing footprint and cost. Over time, reliable voltage regulation and harmonics management translate to decreased downtime, reduced maintenance, and improved productivity in automated production lines.