Eaton N48D28B33EE Nonlinear Transformer - KT-13 3-Phase

Part Number: N48D28B33EE
Manufacturer
Eaton
Part number
N48D28B33EE

Quick Summary

The Eaton N48D28B33EE nonlinear transformer provides reliable voltage conversion for industrial power distribution applications. Real-world installations face voltage swings, harmonic distortion, and heat buildup that can shorten equipment life and increase downtime. Certification details vary by region and may include CE, UL, and IP ratings; confirm with Eaton for exact approvals on your site. With a 3-phase KT-13 design delivering 300 kVA, a 480 V primary, and 208Y/120 V secondary, plus ±2.5% taps, this transformer supports scalable, resilient electrical distribution. Businesses gain improved voltage stability, compliance confidence, and reduced maintenance costs through robust cooling and precise voltage regulation.

Product Information

Extended Description

N48D28B33EE Eaton: Eaton K-Factor nonlinear ventilated transformer, KT-13 (3-phase), PV 480V, Taps: 2 at +2.5% /2 at -2.5%, SV 208Y/120V, 80°C rise, 300 kVA, EE
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48D28B33EE
UPC
786680140808
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Certifications
Contact Manufacturer
Volt ampere rating
300 kVA
Primary voltage
480 V
Secondary Voltage
208 Y/120 V
Feature: 300 kVA three-phase KT-13 nonlinear transformer delivering 480 V to 208Y/120 V. Business Impact: Supports high-load equipment with stable voltages, improving uptime and reducing motor or electronics stress. Application: Automotive assembly lines, CNC machines, and data-center auxiliary systems benefit from consistent power quality. Feature: ±2.5% tap settings (two at +2.5%, two at -2.5%). Business Impact: Enables on-site voltage regulation under fluctuating loads, decreasing production interruptions and extending component life. Application: Facilities with variable input power or long feeders. Feature: K-Factor nonlinear design. Business Impact: Mitigates harmonic distortion, improving power quality and reducing stray heating in nonlinear loads. Application: Industrial automation, robotics, and PLC-based systems where clean voltage is critical. Feature: Ventilated cooling and 80°C rise rating. Business Impact: Maintains thermal performance in compact installations and under peak loading, lowering risk of derating and unplanned downtime. Application: Manufacturing floors and switchgear rooms with limited airflow. Feature: Secondary 208Y/120 V for control circuits and auxiliary equipment. Business Impact: Simplifies control panel wiring and reduces the number of transformers in a power distribution scheme. Application: MCCs, switchgear, and automation cabinets in factories. Feature: 300 kVA rating and 480 V primary suitability. Business Impact: Ideal for transformer banks or as a medium-scale distribution solution, reducing equipment count and footprint. Application: Industrial plants and data centers requiring scalable power conditioning. Insight: This Eaton transformer aligns with common industry standards and documentation from Eaton, including official specification sheets and catalogs, to support procurement, installation, and maintenance planning. Long-tail keywords: Eaton 3-phase transformer, K-Factor transformer, nonlinear ventilated transformer, 480 V to 208Y/120 V, 80°C rise, voltage regulation, harmonic mitigation, power quality improvement.

Get a Quick Quote for a Eaton N48D28B33EE

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48D28B33EE? Enquire Now

FAQs

Plan for a three-phase installation with proper ventilation and adequate space for airflow around the transformer. Ensure the location supports the 80°C rise rating and that the secondary circuits are wired to 208Y/120 V panels or MCCs. Use the ±2.5% taps to tighten voltage under load and verify clearances per local electrical codes during rack or cabinet mounting.
The unit is a 300 kVA, three-phase transformer with a 480 V primary and a 208Y/120 V secondary. It features KT-13 K-Factor nonlinear design, vented cooling, and taps at +2.5% and -2.5% (two each). Operating temperature rise is up to 80°C, making it suitable for medium-load industrial environments.
Yes. Its nonlinear K-Factor design helps mitigate harmonics, improving power quality for sensitive IT equipment and control systems. The 480 V to 208Y/120 V transformation supports data-center auxiliary circuits and factory automation panels, while the taps enable voltage regulation under varying loads common in manufacturing lines.
Certification specifics are provided by the manufacturer and can vary by region. Typical documentation may include CE or UL listings and regional compliance proofs. Contact Eaton or your local distributor to obtain the exact certifications for your installation site and to ensure regulatory alignment before procurement.
The transformer’s ventilated design and 80°C rise rating support reliable long-term operation with manageable thermal performance. The ±2.5% taps aid voltage stability, reducing stress on connected equipment and potentially lowering maintenance costs over time. Regular inspections of cooling paths, connections, and tap settings help sustain efficiency and uptime in industrial environments.