Eaton N48D28B7716QCU General purpose transformer - DOE 2016

Part Number: N48D28B7716QCU
Manufacturer
Eaton
Part number
N48D28B7716QCU

Quick Summary

Eaton General purpose ventilated transformer provides reliable power isolation and distribution for industrial facilities. Engineers often struggle with achieving DOE 2016 efficiency targets while minimizing space and maintenance costs. UL Listed, DOE 2016 Efficient compliance, and a NEMA 1 enclosure support regulatory alignment and protection in indoor environments. Designed for scalable power, this unit delivers 750 kVA at 480 V to 208Y/120 V, enabling efficient, reliable operation across data centers, manufacturing lines, and process plants while reducing total ownership costs.

Product Information

Extended Description

N48D28B7716QCU Eaton: Eaton 750 kVA K-13 DOE 2016 Efficient General Purpose Ventd Transformer PV 480V Delta, 208Y/120, 80C rise, Copper windings, NEMA 1, Q design
Product Name
Eaton General purpose ventilated transformer
Catalog Number
N48D28B7716QCU
UPC
786680236181
Product Length/Depth
44.25 in
Product Height
80.25 in
Product Width
64 in
Product Weight
1.1 lb
Compliances
DOE2016 Efficient
Certifications
UL Listed
Catalog Notes
10 CFR Part 431 (2016) Efficient
Coil material
Copper
Enclosure
NEMA 1
Frame
GPF
Insulation
220 °C
Mounting
Floor
Tap size
+2 at 2.5% FCAN, -2 at 2.5% FCBN
Efficiency
10 CFR Part 431-2016 (DOE 2016)
Frequency rating
60 Hz
Kva Rating
750 kVA
Primary voltage
480 V
Secondary Voltage
208Y/120 V
Sound Level
NEMA ST-20
Temperature rise
80 °C rise
Volt ampere rating
750 kVA
Modification 1
K-13
Feature: 750 kVA kva rating with 480 V primary and 208Y/120 V secondary. Business impact: Enables scalable power distribution for large loads with improved voltage stability and planning headroom. Application: Suitable for data centers, assembly lines, and industrial processes requiring consistent secondary voltages. Feature: DOE 2016 Efficient performance with 80 °C rise and copper windings. Business impact: Reduces energy losses, lowers operating costs, and extends transformer life in continuous-duty applications. Application: Ideal for high-demand facilities pursuing energy efficiency targets in line with DOE guidelines. Feature: NEMA 1 enclosure and floor mounting. Business impact: Simplifies installation in controlled indoor spaces and reduces protection concerns in busy plant floors. Application: Plant rooms, switchgear areas, and loading docks where robust protection and floor mounting are advantageous. Feature: Tap changers (+2 at 2.5% FCAN, -2 at 2.5% FCBN). Business impact: Maintains voltage regulation under supply variations, minimizing equipment stress and downtime. Application: Critical loads with variable input conditions or long feeder runs. Feature: K-13 modification and UL Listed certification. Business impact: Supports regulatory compliance and design flexibility for end users with strict standards. Application: Environments requiring documented DOE, safety, and performance qualifications. Feature: Copper windings, 220 °C insulation, 60 Hz operation. Business impact: Efficient heat transfer, durable construction, and compatibility with common industrial power systems. Application: Industrial facilities with sustained duty cycles and diverse load profiles.

Get a Quick Quote for a Eaton N48D28B7716QCU

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48D28B7716QCU? Enquire Now

FAQs

For floor-mounted, indoor use in controlled spaces, ensure adequate ventilation and clearance around the enclosure, follow manufacturer mounting guidelines, and confirm alignment with DOE efficiency requirements. Verify that the installation area supports the 480 V primary and 208Y/120 V secondary configuration, and confirm any local electrical codes or UL requirements are met.
A 750 kVA transformer provides substantial headroom for peak loads and future expansion. Design considerations include voltage regulation under load, transformer impedance, and ensuring feeder capacity aligns with the 480 V to 208Y/120 V step-down. This enables reliable service for critical equipment while maintaining efficiency and manageable distribution losses.
Yes. With a 750 kVA rating, 480 V primary, and 208Y/120 V secondary, plus UL Listed and DOE 2016 Efficient compliance, it suits data centers, manufacturing lines, and process facilities requiring dependable, energy-efficient power distribution. The NEMA 1 enclosure and copper windings support durable indoor operation and long service life in harsh environments.
The N48D28B7716QCU is UL Listed and DOE 2016 Efficient compliant, with 10 CFR Part 431 notes. These certifications ensure safety, energy efficiency, and regulatory alignment for facilities pursuing energy targets and standard-based procurement.
Copper windings, 220 °C insulation, and a robust 80 °C rise design support durable performance and lower maintenance needs. Energy efficiency through DOE 2016 reduces operating costs, while the K-13 modification provides design flexibility. Routine inspections for enclosure integrity and insulation condition help maximize ROI over the transformer’s service life.