Eaton N48D28F4921CULS48 Transformer - DOE2016 Efficient

Part Number: N48D28F4921CULS48
Manufacturer
Eaton
Part number
N48D28F4921CULS48

Quick Summary

The Eaton N48D28F4921CULS48 Transformer is a high-capacity, energy-efficient power transformer designed for industrial facilities and automation systems. In plants with nonlinear loads, maintaining power quality and controlling energy waste can be a daily challenge. This unit meets DOE2016 Efficient standards, is UL Listed, and features K13 K-Factor for harmonics mitigation, supporting reliable operation in critical control panels and automation cabinets. Its 150 kVA rating and three-phase configuration support a 480 V to 208Y/120 V distribution, enabling seamless integration with standard drives, PLCs, and instrumentation. Designed for retrofit or new-build projects, it reduces operating costs, enhances system resilience, and scales with evolving automation requirements.

Product Information

Extended Description

N48D28F4921CULS48 Eaton: Eaton NextGen K-Factor, DOE2016 CU 48dB, 150KVA, K13 XFMR, 3PH, 480-208Y/120, 115C, D-Taps
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48D28F4921CULS48
UPC
786689670542
Product Length/Depth
31.5 in
Product Height
51 in
Product Width
34.5 in
Product Weight
1200 lb
Compliances
DOE2016 Efficient
Certifications
UL Listed
Wiring connection
305K
Type
Energy-efficient ventilated transformer
Frame
943
Kva Rating
150 kVA
Volt ampere rating
150KVA
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
208Y/120 V
Temperature rise
115 °C rise
Special features
K13
K-Factor nonlinear design with K13 and ventilated cooling addresses harmonic-rich loads. This design reduces harmonic distortion and manages heat more effectively, extending transformer life and minimizing unplanned downtime. Ideal for automation panels and manufacturing lines with nonlinear loads. DOE2016 Efficient compliance ensures lower no-load and load losses, translating to measurable energy savings and cooler operation across shifts. This is critical for plants aiming to reduce energy intensity and strengthen sustainability reporting. 150 kVA rating in a 3-phase, 480 V to 208Y/120 V configuration provides reliable power for PLCs, servo drives, sensors, and instrumentation. With this transformer, facilities can support scalable automation without oversizing equipment. Applications include manufacturing cells, data centers, and control rooms. Ventilated cooling supports higher ambient temperatures and a 115 °C rise, enabling higher continuous duty in hot environments. This reduces the risk of nuisance outages and extends service life. Ideal for hot shops, outdoor enclosures, and retrofit installations where cooling is constrained. UL Listed safety certification facilitates quick procurement and broad acceptance. Together with DOE2016 efficiency, it aligns with corporate compliance and energy programs. This simplifies installation in regulated facilities and reduces vendor risk. Robust physical specs support reliable installation with standard mounting footprints. Frame 943 and 305K wiring connections enable straightforward integration with Eaton and third-party distribution gear. At 31.5 in depth, 34.5 in width, and 51 in height, it fits in typical electrical rooms with proper clearances.

Get a Quick Quote for a Eaton N48D28F4921CULS48

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48D28F4921CULS48? Enquire Now

FAQs

Installation should follow the unit’s mounting footprint (Frame 943) and wiring connection (305K). Ensure proper clearance, ventilation, and rigid electrical room grounding. Use the UL-listed protection devices and follow local codes for three-phase distribution. Plan for 1200 lb weight and confirm access for serviceability and future upgrades.
The transformer features K13 K-Factor design that mitigates harmonic distortion typical of nonlinear loads. This improves power quality, reduces overheating risk, and minimizes nuisance tripping on sensitive equipment. It’s well-suited for drives, PLCs, and mixed-load automation panels where harmonic mitigation is essential.
Yes. The unit is designed to meet DOE2016 Efficient criteria, delivering lower energy losses and cooler operation under load. This translates to measurable energy savings across shifts and supports sustainability reporting and energy management programs.
Ideal for industrial automation, manufacturing lines, and control rooms needing reliable 480 V to 208Y/120 V power, especially where nonlinear loads exist. It supports PLCs, servo drives, instrumentation, and panel power distribution with robust protection and efficiency benefits.
The combination of DOE2016 efficiency, UL safety, and K-Factor harmonic mitigation reduces energy losses, extends equipment life, and lowers maintenance costs. Although site conditions vary, the transformer’s reliability and compatibility with standard plant gear enable predictable downtime reductions and scalable automation investments.