Eaton N48D28T1521CU Transformer - DOE2016 Efficient

Part Number: N48D28T1521CU
Manufacturer
Eaton
Part number
N48D28T1521CU

Quick Summary

Eaton N48D28T1521CU Transformer is a K-Factor nonlinear ventilated transformer for reliable three-phase power distribution. Engineers often face harmonic distortion and heat buildup that shorten equipment life and escalate energy costs. UL Listed and DOE2016 Efficient certifications reinforce safety and energy performance, backed by a K13 core design and D-Taps for installation flexibility. Designed for 480 V input with 208Y/120 V output, its compact footprint and robust build deliver predictable lifecycle performance for data centers, manufacturing, and facility power systems. Leverage this transformer to meet regulatory requirements while improving system reliability and uptime.

Product Information

Extended Description

N48D28T1521CU Eaton: Eaton NG K-Factor Design, DOE2016,CU, D-Taps, 15KVA K13 VENTD XFMR 3Phase 480-208Y/120,480V
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48D28T1521CU
UPC
786689674915
Product Length/Depth
17.75 in
Product Height
28 in
Product Width
21.88 in
Product Weight
430 lb
Compliances
DOE2016 Efficient
Certifications
UL Listed
Type
K13
Primary voltage
480 V
Feature → Business Impact → Application: The K-Factor nonlinear design reduces harmonic currents, improving power quality and extending the life of downstream equipment, which translates to lower maintenance costs in data centers and manufacturing lines. Application: ideal where high-crest factor loads exist and critical equipment uptime matters. Feature → Business Impact → Application: DOE2016 Efficient design lowers operating losses, delivering measurable energy savings and a faster return on investment for facilities aiming to minimize utility bills. Application: broad industrial use, especially facilities striving for energy compliance. Feature → Business Impact → Application: Ventilated cooling enhances heat dissipation, enabling higher continuous load capability and reducing derating in warm environments. Application: acceptable for hot factories or spaces with limited HVAC headroom. Feature → Business Impact → Application: D-Taps provide flexible voltage configurations, simplifying field wiring and enabling quick adaptation to load changes. Application: installations requiring 480V input to 208Y/120V outputs across varied plant sections. Feature → Business Impact → Application: UL Listed certification ensures safety compliance and smoother procurement, reducing risk during audits. Application: regulated industries and projects with stringent safety standards. Feature → Business Impact → Application: 430 lb weight and 17.75 x 21.88 x 28 in footprint inform cabinet and floor space planning, improving site layout and installation time. Application: OEMs and installers prioritizing compact, scalable power distribution.

Get a Quick Quote for a Eaton N48D28T1521CU

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48D28T1521CU? Enquire Now

FAQs

The N48D28T1521CU is designed for 3-phase 480V primary input with a 208Y/120V secondary. Plan for a sturdy floor mounting or cabinet enclosure, allow clearance for ventilation, and verify D-Tap options match the desired secondary voltage. For best results, coordinate with facility electrical drawings and crane access if needed due to its 430 lb weight.
K-Factor nonlinear design targets higher harmonic content in nonlinear loads, reducing resonant risk and improving overall power quality. This leads to lower heat generation in downstream equipment, fewer nuisance trips, and more stable voltage profiles across sensitive loads such as drives and CNC machinery.
Yes. With a 15 kVA rating, 480V to 208Y/120V outputs, DER-rated efficiency, and a K13 design, it supports critical load centers while maintaining energy efficiency. Its robust UL Listed safety and DOE2016 efficiency alignment make it a strong fit for data centers, automation floors, and industrial plants needing reliable power with controlled harmonic distortion.
The N48D28T1521CU carries UL Listed certification and conforms to DOE2016 Efficient standards. These certifications help meet safety and energy-performance requirements, streamline procurement, and simplify compliance during regulatory audits or facility certifications.
The combination of DOE2016 efficiency and reduced harmonic losses lowers operating energy costs over the life of the transformer. Operational benefits include improved uptime, lower maintenance costs due to better power quality, and predictable performance, supporting a favorable ROI for facilities pursuing energy efficiency and reliability goals.