Eaton N48D28T75EELS45 K-Factor nonlinear ventilated transformer - 75 kVA

Part Number: N48D28T75EELS45
Manufacturer
Eaton
Part number
N48D28T75EELS45

Quick Summary

Eaton N48D28T75EELS45 K-Factor nonlinear ventilated transformer provides robust 480 V power conditioning for industrial systems. Engineers face voltage sags and heat in dense switchgear, and reliable harmonic mitigation is essential. This KT-13 three-phase transformer offers taps at +2.5% and -2.5%, enabling better voltage regulation under fluctuating loads. Certifications are listed as Contact Manufacturer, so confirm CE, UL, and SIL as required for your facility with Eaton. In addition, the EE and LS features support energy efficiency and quieter operation, helping reduce utility costs and maintain compliance across critical distribution networks. Overall, it delivers improved reliability, extended equipment life, and easier integration into existing power architectures.

Product Information

Extended Description

N48D28T75EELS45 Eaton: Eaton K-Factor nonlinear ventilated transformer, KT-13 (3-phase), PV 480V, Taps: 2 at +2.5% /2 at -2.5%, SV 208Y/120V, 150°C rise w/ 200°C insulation systeam, 75 kVA, EE, LS, 45
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48D28T75EELS45
UPC
786680141010
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Certifications
Contact Manufacturer
Volt ampere rating
75 kVA
Primary voltage
480 V
Secondary Voltage
208 Y/120 V
Feature: K-Factor nonlinear design mitigates harmonic currents from non-linear loads. Business Impact: improves voltage regulation and reduces transformer overheating, extending equipment life. Application: ideal for data centers, motor drives, and manufacturing lines with nonlinear loads. Feature: 3-phase KT-13 configuration with 480 V primary and 208Y/120 V secondary. Business Impact: standardizes connection schemes, simplifies panel design, and speeds installation while boosting reliability. Application: suitable for new builds and retrofits in industrial facilities with standard 480 V mains. Feature: Primary taps at +2.5% / -2.5% provide voltage headroom. Business Impact: maintains voltage stability under fluctuating loads and long feeders, reducing equipment stress. Application: critical in facilities with variable demand and variable utility supply. Feature: 75 kVA rating aligned to medium-load feeders. Business Impact: optimizes footprint and cost while delivering sufficient reserve for feeders, MCCs, and control panels. Application: ideal for industrial control rooms, packaging lines, and process equipment. Feature: Ventilated design with high temperature insulation (150°C rise; 200°C insulation system). Business Impact: enhanced cooling, higher duty capability, and longer life in hotter environments. Application: fits restricted spaces and retrofit sites where airflow is constrained. Feature: EE, LS compliant construction supports energy efficiency and quieter operation. Business Impact: lowers operating costs and reduces noise, improving worker comfort and compliance. Application: suitable for near-plant offices, racking rooms, and shared facility spaces.

Get a Quick Quote for a Eaton N48D28T75EELS45

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48D28T75EELS45? Enquire Now

FAQs

Follow the Eaton installation guide for a 480 V three-phase system. Connect primary windings to the 480 V supply and route the 208Y/120 V secondary to the respective distribution circuits. Use the +2.5% and -2.5% taps as needed to regulate voltage under load. Ensure proper ventilation, clearance, and adherence to local codes; verify connections match the KT-13 configuration and consult the datasheet for torque specs and mounting guidelines.
Key specs include 75 kVA rating, 480 V primary, 208Y/120 V secondary, KT-13 three-phase configuration, and a K-Factor nonlinear design. It provides primary voltage regulation through ±2.5% taps and uses a ventilation-assisted cooling system rated for 150°C rise with a 200°C insulation system. These details guide protection settings, wiring schemes, and harmonics management for non-linear loads.
Yes. The K-Factor nonlinear design mitigates harmonic currents from non-linear loads, improving voltage stability and protecting downstream equipment. It is well-suited for data centers, motor drives, and manufacturing lines where harmonic content is high and reliability is critical. Verify site-specific compliance with Eaton for any required certifications.
The product lists Certifications as Contact Manufacturer, so confirm required certifications such as CE, UL, or SIL with Eaton prior to procurement. Review the Eaton datasheet and performance documents for relevant test data, and request any country-specific conformity assessments to ensure regulatory compliance for your installation.
Maintenance is typically routine for power transformers: inspect cooling, verify taps not corroded, and monitor insulation integrity and temperature rise. ROI benefits come from improved voltage regulation, reduced harmonic-related losses, and quieter operation (EE/LS design). Align maintenance intervals with Eaton guidelines and your facility’s preventive maintenance program to maximize uptime and lifecycle value.