Eaton N48G28T09 Transformer - UL Listed, K-13

Part Number: N48G28T09
Manufacturer
Eaton
Part number
N48G28T09

Quick Summary

The Eaton N48G28T09 transformer supplies reliable three-phase voltage conversion for industrial power distribution. Engineers often wrestle with overheating, non-linear harmonic stress, and rising maintenance costs in control architectures. UL Listed safety certification ensures compliance for electrical installations, while the K-Factor ventilated design helps manage non-linear loads and heat generation. With aluminum windings, electrostatic shielding, a WS38 weather shield, and a 9 kVA rating, this unit delivers consistent performance in demanding environments. This combination supports reliable control panels and facility power distribution, reducing downtime and driving energy efficiency and total cost of ownership improvements. Its 60 Hz compatibility and output of 480 V to 208Y/120 V further enable widespread industrial automation deployments.

Product Information

Extended Description

N48G28T09 Eaton: K-Factor Non Linear Transformer, Ventilated, K-13, Three-phase, PV: 480V, Taps: 2 at -5% FCBN, SV: 208Y/120V, 150°C, 9 kVA, Al windings, Elec. Shield, Frame: 912B, uses WS38
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48G28T09
UPC
786680067846
Product Length/Depth
16.5 in
Product Height
30 in
Product Width
23 in
Product Weight
200 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Coil material
Aluminum
Type
Ventilated transformer
Design
K-13
Frame
912B
Tap size
2 at -5% FCBN
Frequency rating
60 Hz
Kva Rating
9 kVA
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
208Y/120 V
Temperature rise
150 °C rise
Special features
Electrostatically Shielded
Weathershield
WS38
Feature → Business Impact → Application: The K-Factor nonlinear ventilated design actively mitigates heat buildup under non-linear loads, reducing thermal stress and extending transformer life, which translates to lower maintenance intervals and improved system uptime for data centers and automated facilities. Application: data centers, machine automation, and variable-speed drives. Feature → Business Impact → Application: A 9 kVA three-phase rating provides compact yet sufficient power handling for panel boards and Control Rooms, delivering predictable voltage conversion with minimized footprint in factory floors. Application: control panels, PLC racks, and motor control centers. Feature → Business Impact → Application: Primary 480 V and secondary 208Y/120 V outputs ensure compatibility with common industrial power distribution schemes, simplifying integration with VFDs, hard-starters, and panel boards. Application: machine builders and panel builders. Feature → Business Impact → Application: Two taps at -5% FCBN allow voltage adjustments to maintain regulation under varying load conditions, reducing nuisance tripping and improving control performance. Application: critical automation aisles and robotics. Feature → Business Impact → Application: Aluminum windings, an electrostatic shield, and WS38 weather shield enhance reliability, EMI/EMC performance, and outdoor suitability, lowering installation risk and enabling outdoor or harsh-environment deployments. Application: outdoor substations, covered equipment yards, and harsh industrial environments. Feature → Business Impact → Application: Frame 912B and a 200 lb weight balance structural integrity with straightforward mounting in standard electrical rooms, facilitating safer, faster installations. Application: retrofit projects and new builds. Feature → Business Impact → Application: UL Listed certification confirms safety compliance for industrial electrical installations, while the included warranty reduces total cost of ownership and risk for procurement teams. Application: compliance-driven purchases and maintenance planning.

Get a Quick Quote for a Eaton N48G28T09

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48G28T09? Enquire Now

FAQs

Install on a flat, solid mounting surface using the 912B frame footprint. Allow adequate ventilation for the 150 C rise rating and ensure WS38 weather protection if installed in exposure zones. Connect the primary to 480 V and secondary to 208Y/120 V circuits, following the enclosure manufacturer’s clearance and conduit guidelines.
It uses a K-Factor nonlinear design with aluminum windings and an electrostatic shield to manage harmonic currents and reduce heat buildup. This lowers overheating risk, helps maintain voltage stability, and supports reliable operation of drives and rectifier-fed equipment under non-linear loading.
Rated at 9 kVA, it is a three-phase transformer operating at 60 Hz with a 480 V primary and 208Y/120 V secondary. The two taps at -5% FCBN allow voltage adjustment to stabilize output under varying load; this improves regulation and reduces nuisance trips in automation systems.
Yes, the unit is UL Listed, confirming compliance with recognized safety standards for electrical equipment intended for industrial installations. This reduces procurement risk and supports compliance in facilities that require certified electrical components.
Eaton provides a warranty per policy 25-000: one year from installation or 18 months from shipment, whichever occurs first. For maintenance, ensure ventilation is unobstructed, inspect the electrostatic shield and windings periodically, and verify WS38 weather shield integrity in outdoor installations.