Eaton N48M24B4516CU Transformer - K-Factor 13

Part Number: N48M24B4516CU
Manufacturer
Eaton
Part number
N48M24B4516CU

Quick Summary

Eaton N48M24B4516CU transformer delivers efficient power conditioning for industrial facilities requiring reliable three-phase distribution. Facilities often struggle with harmonic distortion, energy waste, and space constraints that complicate critical loads. This UL Listed unit also aligns with DOE 2016 Efficient standards and 10 CFR Part 431, supporting regulatory compliance and sustainability goals. Its copper windings and K-Factor 13 design deliver dependable, compact power delivery, while 480 to 240 volt delta service supports legacy equipment and modernization efforts without expanding footprint.

Product Information

Extended Description

N48M24B4516CU Eaton: Eaton Eaton K-Factor nonlinear ventilated transformer, Copper windings, NEMA 2, FR942, 60 Hz, 220C, 45 kVA, Three-Phase, 480 to 240 DELTA, 80C rise, Shielded, DOE 2016, WS59, 295B, K13
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M24B4516CU
UPC
786680245084
Product Length/Depth
24 in
Product Height
43 in
Product Width
30.5 in
Product Weight
692 lb
Compliances
DOE2016 Efficient
Certifications
UL Listed
Catalog Notes
10 CFR Part 431 (2016) Efficient
Coil material
Copper
Enclosure
NEMA 2
Wiring connection
295B
Type
Energy-efficient ventilated transformer
Frame
942
Insulation
220 °C
Mounting
Floor or wall, upright only
Tap size
2 at +2.5%, 4at -2.5%
Frequency rating
60 Hz
Kva Rating
45 kVA
Volt ampere rating
45 kVA
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
240 V
Sound Level
NEMA ST-20
Temperature rise
80 °C rise
Efficiency
10 CFR Part 431-2016 (DOE 2016)
Modification 1
Electrostatic shield
Special features
K-factor 13
Weathershield
WS59
Feature → Business Impact → Application: The K-Factor nonlinear ventilated design mitigates harmonics and reduces overheating, delivering cleaner power and improved uptime for sensitive equipment in manufacturing lines and HVAC systems. This translates to reduced maintenance costs and longer asset life in continuous-process environments. Feature → Business Impact → Application: Copper windings with an electrostatic shield minimize energy losses and EMI, enhancing protection for nearby control systems and ensuring stable operation in electric drives and robotics workflows. Feature → Business Impact → Application: NEMA 2 enclosure with robust FR942 frame supports rugged factory conditions, enabling floor or wall mounting and simplifying installation in existing plant rooms or retrofit projects. Feature → Business Impact → Application: Tap size options of 2 at +2.5% and 4 at -2.5% enable fine voltage balancing for diverse plant loads, improving voltage stability for extrusion lines, presses, or CNC controllers. Feature → Business Impact → Application: DOE 2016 Efficiency and UL Listing provide regulatory confidence and energy savings across large facilities, while weather shielding WS59 supports outdoor or semi-exposed installations in industrial yards. Feature → Business Impact → Application: 60 Hz, 45 kVA, three-phase configuration ensures scalable, room-friendly power transformation for multi-line manufacturing and data-center support rooms. These specifications help engineers meet compliance, optimize energy use, and maintain uptime with fewer spare parts.

Get a Quick Quote for a Eaton N48M24B4516CU

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M24B4516CU? Enquire Now

FAQs

Plan for floor or wall mounting in a secured service area, allowing upright orientation as specified. Expect a substantial footprint (30.5 in wide by 43 in high) and weight around 692 lb. Ensure adequate ventilation, access for connections (Wiring 295B), and proximity to loads in a NEMA 2 enclosure environment to maintain performance and serviceability.
Yes. The transformer features a K-Factor of 13 and a nonlinear ventilated design to mitigate harmonics, alongside copper windings and an electrostatic shield to reduce EMI. This combination supports stable operation for sensitive drives, CNC systems, and robotics with reduced risk of nuisance tripping and control instability.
The unit provides a 480 V primary and 240 V secondary in a three-phase configuration. It supports delta connections, specifically noted as 480 to 240 DELTA, enabling compatibility with legacy equipment and certain plant electrical designs while maintaining efficient transformation at 60 Hz.
The N48M24B4516CU comes UL Listed and complies with DOE 2016 Efficient requirements, with catalog notes referencing 10 CFR Part 431 (2016) Efficient. These certifications help ensure regulatory alignment, energy efficiency incentives, and simplified procurement for projects with strict compliance criteria.
Maintenance needs are typical of industrial power transformers, with emphasis on routine inspections of enclosure integrity, cooling pathways, and connections. The energy efficiency and reduced heat generation from DOE 2016 compliance contribute to lower operating costs over time, while the rugged copper-windings design supports longer service life and lower replacement frequency in demanding environments.