Eaton N48M28F22AFEELS52 Nonlinear Ventilated Transformer - Fungus-Proof

Part Number: N48M28F22AFEELS52
Manufacturer
Eaton
Part number
N48M28F22AFEELS52

Quick Summary

Eaton N48M28F22AFEELS52 nonlinear ventilated transformer delivers reliable voltage conditioning for three-phase power distribution in industrial facilities. In demanding environments, voltage swings, heat buildup, and noise can disrupt uptime and shorten equipment life. Certifications vary by installation; consult the manufacturer for CE, IP, or SIL confirmation, while the unit is designed for NEMA TP-1 efficiency and fungus-proof performance. With a robust 225 kVA rating and a footprint optimized for retrofit, it supports scalable power protection and lowers total cost of ownership.

Product Information

Extended Description

N48M28F22AFEELS52 Eaton: Eaton K-Factor nonlinear ventilated transformer, KT-13 (3-phase), PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 208Y/120V, 115°C rise, 225 kVA, Fungus proof, EE, LS52
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M28F22AFEELS52
UPC
786680111488
Product Length/Depth
36.23 in
Product Height
75 in
Product Width
44.2 in
Product Weight
2492 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
Contact Manufacturer
Catalog Notes
NEMA TP-1 efficient Fungus proof Low sound design equivalent to 52 dB.
Coil material
Aluminum
Wiring connection
292A
Type
Nonlinear ventilated transformer
Frame
919E
Tap size
2 at +2.5% FCAN 4 at -2.5% FCBN
Frequency rating
60 Hz
Volt ampere rating
225 kVA
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
208 Y/120 V
Temperature rise
115 °C rise
Special features
Electrostatically shielded
Weathershield
WS35
Feature: High kVA, 225 kVA rating with 480 V primary and 208Y/120 V secondary. Business impact: Enables stable power delivery to equipment clusters while tolerating harmonic distortion, reducing voltage fluctuations and protecting sensitive loads. Application: Data center racks and manufacturing lines requiring dependable three-phase power. Feature: +2.5% / -2.5% tap capability. Business impact: Facilitates voltage compensation on-site, minimizing voltage drop and equipment stress during transients. Application: Facilities with irregular utility feeds or long feeder runs. Feature: Aluminum coil and electrostatic shielding. Business impact: Improves thermal performance and EMI containment, enabling safer operation in densely powered environments. Application: Process plants and automation centers with mixed loads. Feature: WS35 weather shield and fungus-proof construction. Business impact: Enhances reliability in humid or corrosive environments, reducing maintenance cycles. Application: Outdoor or semi-outdoor installations and harsh environments. Feature: Low sound design and 115 °C rise rating. Business impact: Reduces audible noise and supports cooler operation under load, extending component life. Application: Noise-sensitive facilities and high-temperature plant rooms. Feature: Frame 919E and 292A wiring connection. Business impact: Supports straightforward mounting and wiring in standard electrical rooms, easing installation. Application: Retrofit projects and new builds with limited space.

Get a Quick Quote for a Eaton N48M28F22AFEELS52

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M28F22AFEELS52? Enquire Now

FAQs

Consider floor space and weight; this unit weighs about 2492 lb and uses a 919E frame, requiring a sturdy foundation and appropriate clearance for ventilation and service access. Plan for WS35 weather shielding if outdoor or semi-outdoor use and ensure adequate electrical room clearances for wiring connections (292A). Verify mounting provisions and electrical code compliance with the site’s standards and Eaton’s installation guides.
Verify a 225 kVA VA rating, 480 V primary voltage, and 208 Y/120 V secondary voltage for correct load matching. Confirm 60 Hz frequency, three-phase configuration, and tap settings of +2.5% / -2.5% to accommodate site voltage variations. Check insulation and copper/aluminum coil considerations, and ensure wiring conductor sizing aligns with 292A connection and frame 919E constraints.
Yes, it is designed with WS35 weather protection and fungus-proof construction suitable for challenging environments. The electrostatic shielding further improves EMI performance, making it appropriate for facilities with high ambient humidity or contamination. When outdoor use is planned, confirm enclosure integrity and ventilation align with local codes and site conditions.
Certifications are listed as ‘Contact Manufacturer’ for this model. In practice, you should request official certificates or test reports from Eaton to confirm CE, IP, SIL, or other region-specific approvals. Use the manufacturer’s documentation and the official spec sheet to verify compliance and ensure the unit meets your regulatory and safety requirements.
The 225 kVA nonlinear ventilated transformer offers high efficiency with NEMA TP-1 alignment and fungus-proof design, which reduces energy loss and maintenance intervals in humid environments. Its robust 115 °C rise rating supports reliable operation under heavier loads, while the one-year warranty (or 18 months from shipment) provides a clear depreciation period. Consider the total cost of ownership improvements from reduced downtime and longer service life when evaluating ROI.