Eaton N48M28F22EES2 Transformer - 225 kVA K-Factor

Part Number: N48M28F22EES2
Manufacturer
Eaton
Part number
N48M28F22EES2

Quick Summary

The Eaton N48M28F22EES2 transformer delivers K‑Factor nonlinear power conditioning for industrial distribution applications. Many plants struggle with harmonic distortion and voltage swings that stress drives and controls. Common certifications for this class include CE marking and UL safety recognition; SIL ratings and IP protection depend on enclosure and installation context. With a 225 kVA rating and adjustable taps, this solution combines reliability with flexibility, supporting energy efficiency and safer equipment life in critical processes. For procurement teams, this translates to fewer outages, easier compliance reporting, and predictable budgeting for upgrades. Engineers will value its compatibility with standard 3‑phase industrial distributions and Eaton’s support resources.

Product Information

Extended Description

N48M28F22EES2 Eaton: Eaton K-Factor nonlinear ventilated transformer, KT-13 (3-phase), PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 208Y/120V, 115°C rise, 225 kVA, EE, S2
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M28F22EES2
UPC
786680140679
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Certifications
Contact Manufacturer
Volt ampere rating
225 kVA
Primary voltage
480 V
Secondary Voltage
208 Y/120 V
Feature: K‑Factor nonlinear ventilated transformer design. This approach reduces harmonic currents and voltage distortion, protecting sensitive drives and controls while improving overall power quality for critical processes in manufacturing, metalworking, and packaging lines. Feature: Taps at +2.5% and -2.5% provide voltage regulation. The business impact is tighter voltage control, reducing motor stall, equipment stress, and nuisance trips across fluctuating grids; applications include panel boards, motor control centers, and critical plant feeders. Feature: 3-phase KT-13, 225 kVA rating. This configuration simplifies integration with existing 480 V/208 Y/120 V utilities and minimizes transformer bank footprint in switchgear rooms. Feature: 115°C rise rating. This capability supports hotter environments with less derating, increasing uptime in high-ambient plants such as foundries and warehouses with limited cooling. Feature: Ventilated design for robust cooling. Improved thermal performance lowers maintenance needs and extends service life in continuous operations. Feature: Documentation and resources. Access to Eaton specification sheets and the Transformer Flex Center enhances planning, approval cycles, and field installation success.

Get a Quick Quote for a Eaton N48M28F22EES2

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M28F22EES2? Enquire Now

FAQs

The N48M28F22EES2 is a three‑phase transformer designed for standard industrial power distribution. It supports a 480 V primary and 208 Y/120 V secondary configuration, with taps at +2.5% and -2.5% to accommodate voltage variations. Use it in switchgear, distribution panels, and motor control centers where Eaton equipment and service support are available for integration and commissioning.
The K‑Factor nonlinear design mitigates harmonic currents and voltage distortion, protecting sensitive loads such as drives and controls. This results in improved power quality, fewer nuisance trips, longer motor life, and reduced cooling and maintenance requirements in environments with harmonic-rich loads common to modern manufacturing and processing facilities.
Yes, the N48M28F22EES2 is built for demanding industrial settings with a 115°C rise rating and a ventilated construction that supports better cooling under high ambient conditions. While enclosure protection and installation location influence exposure tolerance, the design emphasizes reliability and uptime in hot, busy plants like foundries, metal shops, and large warehouses.
Plan for a straightforward 3‑phase connection to existing 480 V feeders or switchgear, with attention to proper ventilation and clearance for airflow. The ability to adjust taps helps maintain voltage within tolerance, reducing equipment stress. Over the lifecycle, improved power quality lowers maintenance costs, minimizes downtime, and extends the life of downstream equipment, delivering measurable ROI.
Eaton provides a specification sheet, catalog references, and product videos to assist engineering and procurement teams. Key documents include the Eaton Specification Sheet for N48M28F22EES2 and the transformer distribution catalog, plus the Transformer Flex Center resource for planning and installation guidance.