Eaton N48M28F30CUNVLS45 K-Factor Transformer - UL Listed

Part Number: N48M28F30CUNVLS45
Manufacturer
Eaton
Part number
N48M28F30CUNVLS45

Quick Summary

Eaton N48M28F30CUNVLS45 is a K-Factor nonlinear transformer for three-phase power distribution applications. In practice, engineers face voltage drift, startup surges, and heat buildup that can disrupt operations and shorten equipment life. UL Listed safety certification backs compliance, while the totally enclosed non-ventilated design and low 45 dB sound level help meet space and noise requirements, backed by electrostatic shielding for EMI control. With 30 kVA capacity and copper windings, this transformer supports robust loads in manufacturing, data centers, and automation panels, while voltage taps enable site-specific adjustments to maintain steady voltages across varying supply conditions.

Product Information

Extended Description

N48M28F30CUNVLS45 Eaton: K-Factor Non Linear Transformer, Non-Ventilated, K-13, Three-phase, PV: 480V, Taps: 2 at +2.5% FCAN, 4 at -2.5% FCBN, SV: 208Y/120V, 115°C, 30 kVA, Cu windings, Elec. Shield, Frame: 916AN
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M28F30CUNVLS45
UPC
786680075254
Product Length/Depth
23.42 in
Product Height
46.58 in
Product Width
28.22 in
Product Weight
968 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Totally enclosed non-ventilated, Low sound equal to 45 dB
Coil material
Copper
Type
Ventilated transformer
Design
K-13
Frame
916AN
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
60 Hz
Kva Rating
30 kVA
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
208Y/120 V
Temperature rise
115 °C rise
Modification 1
Low sound 45 dB
Special features
Electrostatically Shielded
K-Factor nonlinear design (K-13) delivers reduced harmonic distortion and cleaner voltage in nonlinear loads, which lowers equipment stress and extends motor life. This translates to fewer nuisance trips and improved uptime in drives and automation panels. The 30 kVA rating coupled with a 480 V to 208Y/120 V output supports substantial loads with room to scale in switchgear and distribution panels. The voltage taps—2 at +2.5% and 4 at -2.5%—provide practical flexibility to compensate for supply fluctuations, reducing voltage drift and optimizing performance at remote sites or with fluctuating inputs. Copper windings and a 115 °C rise design enhance insulation reliability and thermal endurance, while an electrostatic shield adds EMI protection for sensitive electronics in harsh environments. The enclosure is totally enclosed non-ventilated with a low 45 dB sound footprint, enabling quiet operation in customer-facing or confined spaces. UL Listed certification supports procurement and compliance, while the robust 916AN frame and a weight of 968 lb ensure durable service in demanding industrial settings. Finally, the compact footprint and panel-friendly dimensions simplify integration and mounting within existing electrical rooms.

Get a Quick Quote for a Eaton N48M28F30CUNVLS45

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M28F30CUNVLS45? Enquire Now

FAQs

This transformer uses a 916AN frame and weighs about 968 lb, with overall dimensions of 23.42 in (depth) by 28.22 in (width) by 46.58 in (height). It is designed as a totally enclosed non-ventilated unit with a low 45 dB sound level, making it suitable for cabinet or wall mounting in service corridors or electrical rooms where space and noise limits matter. Ensure adequate clearance for service access and connection wiring per Eaton installation guidelines.
The N48M28F30CUNVLS45 is a three-phase, 60 Hz transformer rated at 30 kVA with a 480 V primary and 208Y/120 V secondary. It has copper windings, an electrostatic shield, and a temperature rise of 115 °C. Voltage taps include 2 at +2.5% and 4 at -2.5%, supporting site voltage variation. The enclosure is totally enclosed and non-ventilated, designed for reliability in industrial environments.
Yes, the N48M28F30CUNVLS45 is well-suited for data centers, manufacturing floors, and other heavy-industrial applications. Its K-Factor nonlinear design manages non-linear loads, while the electrostatic shield mitigates EMI risks to sensitive equipment. The 30 kVA capacity provides ample headroom for critical drives and protection schemes, and the UL Listed certification supports compliance and procurement in regulated facilities.
The transformer is UL Listed, confirming compliance with essential safety standards for electrical distribution equipment. This certification simplifies procurement for regulated environments and cachet for integrators handling electrical installations. The unit’s totally enclosed non-ventilated construction and low-noise profile also align with facility requirements for noise-sensitive areas, while copper windings and shielding contribute to durability and performance.
ROI benefits arise from improved power quality, reduced downtime, and lower maintenance costs. The copper windings and robust insulation with 115 °C rise support long service life in demanding environments. Voltage taps reduce voltage drift, while EMI shielding minimizes failures due to electrical noise. A one-year warranty (or eighteen months from shipment per Eaton policy) provides initial risk protection for procurement.