Eaton N48M28T09CU Nonlinear Ventilated Transformer - UL Listed

Part Number: N48M28T09CU
Manufacturer
Eaton
Part number
N48M28T09CU

Quick Summary

Eaton N48M28T09CU nonlinear ventilated transformer enables reliable power distribution for three-phase industrial control panels. In dense electrical installations, voltage stability and heat buildup are common pain points that can drive maintenance costs and downtime. UL Listed certification supports safety compliance in critical installations. With copper windings, a 150°C rise, and a 9 kVA rating, this transformer blends rugged protection with efficient operation to support ongoing productivity in automation environments.

Product Information

Extended Description

N48M28T09CU Eaton: K-Factor Non Linear Transformer, Ventilated, K-13, Three-phase, PV: 480V, Taps: 2 at +2.5% FCAN, 4 at -2.5% FCBN, SV: 208Y/120V, 150°C, 9 kVA, Cu windings, Elec. Shield, Frame: 912B, uses WS38
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M28T09CU
UPC
786680053368
Product Length/Depth
16.5 in
Product Height
30 in
Product Width
23 in
Product Weight
214 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Coil material
Copper
Type
Ventilated transformer
Design
K-13
Frame
912B
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
60 Hz
Kva Rating
9 kVA
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
208Y/120 V
Temperature rise
150 °C rise
Special features
Electrostatically Shielded
Weathershield
WS38
The N48M28T09CU uses a K-13 design that delivers robust fault tolerance and predictable voltage performance, reducing nuisance outages and improving control reliability in automated lines. The copper windings provide superior conductivity and long-term durability, translating into lower energy losses and cooler operation in high-current applications. Its ventilated construction enhances heat dissipation, which supports consistent performance in crowded switchgear racks and minimizes thermal derating during peak loads. The unit is ship-ready for standard enclosures and features a 60 Hz frequency rating, reinforcing compatibility with common plant electrical systems. Tap options (+2.5% FCAN and -2.5% FCBN) enable fine voltage compensation at the point of use, reducing field adjustments and improving overall system stability. The WS38 weathershield option and frame 912B sizing simplify outdoor or harsh-indoor installations, while electrostatic shielding adds an extra layer of protection for sensitive equipment. Warranty alignment with Eaton policy provides predictable service, and UL Listed certification reinforces compliance across industrial environments. In practice, installers gain a straightforward path to reliable power conversion with minimal customization, while maintenance teams benefit from clear accessibility and proven long-term performance.

Get a Quick Quote for a Eaton N48M28T09CU

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M28T09CU? Enquire Now

FAQs

This transformer is a three-phase 60 Hz unit with a 480 V primary and 208Y/120 V secondary, designed for standard electrical enclosures. With a 912B frame, 30 in height, 23 in width, and 16.5 in depth, it fits typical industrial racks. Weighing 214 lb, it supports straightforward bolting, wiring, and field serviceability, while the WS38 option enhances outdoor durability.
Key specs include a 9 kVA rating, 60 Hz operation, copper windings, and a 150°C rise rating. Primary voltage is 480 V with a secondary of 208Y/120 V. Taps are available at 2 positions: +2.5% FCAN and 4 positions: -2.5% FCBN to fine-tune voltage. The design is UL Listed and electrostatically shielded for safety and reliability.
Yes. The unit uses a ventilated design to improve cooling in crowded panels and features an electrostatic shield for enhanced safety. The WS38 weather shield option supports outdoor or harsh indoor environments. Copper windings and robust frame construction provide durability in continuous operation, reducing the risk of thermal-related performance drift in automation equipment.
The N48M28T09CU carries UL Listed certification, signaling compliance with rigorous safety standards for electrical equipment. This designation helps meet regulatory requirements for industrial installations and simplifies procurement for engineering teams seeking verified, safe components for control panels and switchgear.
The copper windings and efficient ventilation minimize energy losses and heat-related derating, contributing to lower operating costs and improved reliability. The 9 kVA rating supports consistent performance under peak loads, while the taps enable voltage compensation to reduce field adjustments. A standard warranty and established Eaton support program help manage maintenance planning and total cost of ownership.