Eaton N48M28T22CUEESS Transformer - NEMA TP-1

Part Number: N48M28T22CUEESS
Manufacturer
Eaton
Part number
N48M28T22CUEESS

Quick Summary

Eaton K-Factor nonlinear ventilated transformer powers critical three-phase loads with robust harmonic handling for industrial and data-center environments. Firms often struggle with harmonic distortion, voltage fluctuations, and space-constrained installations that threaten uptime. This unit is UL Listed and NEMA TP-1 compliant, featuring a Grade 304 stainless steel enclosure with WS37S weather protection to withstand harsh conditions. With copper windings and a 225 kVA rating, it delivers reliable performance while enabling scalable control-system resilience and energy-management benefits across manufacturing lines and distribution centers.

Product Information

Extended Description

N48M28T22CUEESS Eaton: Eaton K-Factor nonlinear ventilated transformer, KT-13 (3-phase), PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 208Y/120V, 150°C rise w/ 200°C insulation systeam, 225 kVA, Copper windings, EE, SS
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M28T22CUEESS
UPC
786680058882
Product Length/Depth
32.65 in
Product Height
57.54 in
Product Width
36.69 in
Product Weight
2159 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA TP-1 Compliant
Certifications
UL Listed
Catalog Notes
Nema TP-1 efficient, Grade 304 stainless steel enclosure
Coil material
Copper
Frame
923
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
60 Hz
Volt ampere rating
225 kVA
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
208 Y/120 V
Temperature rise
150 °C rise
Special features
Electrostatically Shielded
Weathershield
WS37S
Feature → Business Impact → Application: The K-Factor nonlinear design mitigates harmonic currents, reducing overheating risk and extending transformer life, which translates to lower maintenance costs and higher equipment uptime in environments with nonlinear loads such as VFDs and PLC-driven automation. This supports improved process stability and predictive maintenance programs in manufacturing and material handling facilities. Application: ideal for control panels, drives-heavy lines, and critical power conditioning where uptime is essential. Feature → Business Impact → Application: 225 kVA three-phase rating paired with a 480 V primary and 208Y/120 V secondary delivers precise load transfer and voltage conversion for mixed-output automation systems, enabling seamless integration with MCCs and switchgear while minimizing voltage drop on sensitive equipment. Application: data centers, packaging lines, and process industries requiring dependable sectional power distribution. Feature → Business Impact → Application: Copper windings reduce resistance losses, improving overall efficiency and thermal performance, which lowers operating costs and supports longer service intervals in high-demand environments. Application: heavy-duty mechanical and process industries with continuous operation. Feature → Business Impact → Application: Taps of +2.5% and -2.5% provide voltage-flexibility to compensate for supply swings, supporting stable PLCs, sensors, and motor drives in fluctuating plant conditions. Application: facilities with irregular or long feeder runs. Feature → Business Impact → Application: Grade 304 stainless steel enclosure with NEMA TP-1 compliance and WS37S weather shield offers corrosion resistance and weather protection, reducing enclosure maintenance and enabling outdoor or semi-enclosed installations. Application: outdoor substations, exposed plant rooms, and coastal facilities. Feature → Business Impact → Application: Dimensions and weight (32.65 in L × 36.69 in W × 57.54 in H; ~2159 lb) inform rack, pad, and space planning, ensuring correct clearance, ventilation, and seismic considerations for new-build or retrofit projects. Application: large industrial projects with stringent space planning and safety requirements.

Get a Quick Quote for a Eaton N48M28T22CUEESS

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M28T22CUEESS? Enquire Now

FAQs

Plan for a three-phase installation with a 480 V primary and 208Y/120 V secondary. Verify enclosure mounting (Grade 304 stainless steel, WS37S weather shield), ensure proper grounding, and utilize the +2.5% / -2.5% taps to compensate for voltage fluctuations. Confirm space for airflow and attach to appropriate switchgear or MCCs using standard NEMA TP-1 compliant mounting.
It uses a K-Factor nonlinear design, which is optimized to handle nonlinear harmonic currents without overheating, maintaining performance under heavy VFD and drive-driven loads common in modern manufacturing. This reduces the risk of insulation stress and improves long-term reliability.
Yes. It is UL Listed and NEMA TP-1 compliant, with a corrosion-resistant Grade 304 stainless steel enclosure and WS37S weather shield, making it suitable for harsh or outdoor environments and ensuring compliance with safety and performance standards.
The Grade 304 stainless steel enclosure with WS37S weather shield offers robust corrosion resistance and weather protection, reducing enclosure maintenance while supporting outdoor or semi-enclosed installations. This simplifies site work and improves longevity in challenging plant conditions.
With copper windings and a 225 kVA rating, the unit delivers efficient load handling and lower operational losses, contributing to faster payback through energy savings and reduced downtime. A one-year warranty (or 18 months from shipment) provides initial risk mitigation while supporting long-term maintenance planning.