Eaton N48M28T22CULS52 Transformer - UL Listed

Part Number: N48M28T22CULS52
Manufacturer
Eaton
Part number
N48M28T22CULS52

Quick Summary

Eaton N48M28T22CULS52 transformer delivers K-Factor nonlinear power transformation for industrial systems. Many users struggle with harmonic distortion, heat buildup, and noise in large power transformers, complicating reliability and maintenance. This unit carries UL Listed certification to meet rigorous safety standards in industrial environments, and its K-13 design, copper windings, and electrostatic shielding help reduce losses and stray currents. With three-phase 225 kVA capacity and a 480 V primary to 208Y/120 V secondary, it supports high-demand applications while staying compliant with standard electrical safety expectations. The combination of robust performance and Eaton's service support translates into lower lifecycle costs and smoother installation in manufacturing, data centers, and process facilities.

Product Information

Extended Description

N48M28T22CULS52 Eaton: K-Factor Non Linear Transformer, Ventilated, K-13, Three-phase, PV: 480V, Taps: 2 at +2.5% FCAN, 4 at -2.5% FCBN, SV: 208Y/120V, 150°C, 225 kVA , Cu windings, Elec. Shield, Frame: 918A, uses WS34
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M28T22CULS52
UPC
786680027499
Product Length/Depth
30.68 in
Product Height
62.18 in
Product Width
31.44 in
Product Weight
2226 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Low sound equal to 52 dB
Coil material
Copper
Type
Ventilated transformer
Design
K-13
Frame
918A
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
60 Hz
Kva Rating
225 kVA
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
208Y/120 V
Temperature rise
150 °C rise
Modification 1
Low sound 52 dB
Special features
Electrostatically Shielded
Weathershield
WS34
Feature → Business Impact → Application: K-Factor nonlinear design reduces harmonic currents and improves overall power quality, enabling cleaner operation of sensitive equipment and extended component life in demanding processes. Application: manufacturing floors and data centers where harmonic stability is critical. Feature → Business Impact → Application: Copper windings with electrostatic shielding minimize resistive losses and EMI coupling, boosting efficiency and safeguarding nearby control electronics. Application: control panels and motor drives in mid-to-large installations. Feature → Business Impact → Application: Tap settings 2 at +2.5% and 4 at -2.5% provide precise voltage regulation, reducing voltage imbalance and equipment stress. Application: facilities with fluctuating supply conditions. Feature → Business Impact → Application: Frame 918A and WS34 weathershield enable rugged, install-ready mounting in indoor and outdoor environments, lowering installation time and improving durability. Application: outdoor substations and harsh environments. Feature → Business Impact → Application: Low sound 52 dB catalog note supports quieter operation on the plant floor, improving worker comfort and reducing acoustic concerns in open facilities. Application: manufacturing lines and data centers with noise constraints. The product’s three-phase 225 kVA rating, 60 Hz operation, and 480 V to 208Y/120 V secondary make it a robust choice for industrial power distribution, while UL Listed certification provides confidence in compliance and safety during procurement and installation.

Get a Quick Quote for a Eaton N48M28T22CULS52

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M28T22CULS52? Enquire Now

FAQs

For installation, verify primary 480 V supply and 208Y/120 V secondary connections, ensure adequate ventilation for the ventilated transformer, and confirm WS34 weathershield suitability if outdoor use is anticipated. Plan for frame 918A mounting, provide proper clearance for heat dissipation, and reference the catalog notes for sound levels (52 dB) to align with plant noise criteria.
Key specs include a 225 kVA rating, 60 Hz frequency, three-phase configuration, primary voltage 480 V, secondary 208Y/120 V, and taps of 2 at +2.5% and 4 at -2.5%. The transformer uses copper windings, has an electrostatic shield, a frame 918A, with a 150°C rise rating and a low-noise profile of 52 dB.
Yes, the unit is equipped with WS34 weathershield compatibility and a rugged frame (918A) that supports outdoor installations in appropriate environments. Ensure proper enclosure protection, follow clearance for ventilation, and confirm ambient temperature and humidity conditions align with the 150°C rise rating and UL Listed safety certification.
The K-Factor nonlinear design helps mitigate harmonic currents and improves overall power quality, reducing stress on upstream and downstream equipment. This translates to longer component life, lower maintenance costs, and better compliance with harmonic standards in facilities with sensitive drives and controllers.
The N48M28T22CULS52 is covered by Eaton's warranty policy, which provides one year from installation or eighteen months from shipment, whichever comes first. In addition, Eaton offers technical support and access to specification sheets and catalogs to aid in sizing, integration, and ongoing maintenance.