Eaton N48M28T3021CUHDI3 K-Factor Nonlinear Ventilated Transformer - UL Listed

Part Number: N48M28T3021CUHDI3
Manufacturer
Eaton
Part number
N48M28T3021CUHDI3

Quick Summary

Eaton N48M28T3021CUHDI3 K-Factor nonlinear ventilated transformer is designed to deliver reliable power conditioning for three-phase 480 Vac to 208Y/120 Vac systems in industrial facilities. Engineers often struggle with heat buildup, insulation stress, and harmonics when scaling power for critical equipment. The UL Listed unit addresses these challenges with a vented XFMR design and a robust 30 kVA rating, enabling predictable performance and longer service life. By combining efficient energy handling with installation flexibility, it supports uptime, reduces maintenance costs, and aligns with power-management and distribution project goals for modern facilities.

Product Information

Extended Description

N48M28T3021CUHDI3 Eaton: Eaton K-Factor nonlinear ventilated transformer, Vented XFMR, 30 kVA, K13, Three-phase, 480-208Y/120
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M28T3021CUHDI3
UPC
786689663971
Product Length/Depth
35.57 in
Product Height
51 in
Product Width
34.5 in
Product Weight
1093 lb
Certifications
UL Listed
Type
Vented XFMR
Kva Rating
30 kVA
Phase
Three-phase
Voltage rating
480 Vac-208Y/120 Vac
Feature → Business Impact → Application: The K-Factor nonlinear design effectively manages non-sinusoidal loads, reducing overheating and extending insulation life while maintaining transformer reliability in harsh industrial mains. This translates to fewer derating events, lower maintenance costs, and improved equipment availability in manufacturing lines and automation panels. Feature → Business Impact → Application: The vented XFMR enclosure enhances heat dissipation, enabling stable operation under harmonic-rich conditions common in motor drives and DC drives, which minimizes thermal stress and helps sustain uptime in high-density electrical rooms. Feature → Business Impact → Application: With a 30 kVA three-phase rating and a primary 480 Vac to secondary 208Y/120 Vac configuration, the transformer supports mid-sized loads for panelboards, distribution blocks, and critical equipment racks, delivering scalable power conditioning for expanding plants. Feature → Business Impact → Application: UL Listed certification provides safety and regulatory confidence, reducing audit risk and simplifying approval processes for regulated environments such as food & beverage, automotive, and data-center installations. Feature → Business Impact → Application: When paired with Eaton installation accessories and standard mounting schemes, installation time is reduced, allowing faster commissioning and predictable integration with existing power-management and distribution architectures.

Get a Quick Quote for a Eaton N48M28T3021CUHDI3

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M28T3021CUHDI3? Enquire Now

FAQs

The N48M28T3021CUHDI3 uses a 480 Vac primary and 208Y/120 Vac secondary configuration with a 30 kVA rating, designed for three-phase systems. When planning a panel, confirm available space for the 1093 lb unit, ensure adequate cooling around the vented enclosure, and verify mounting compatibility with standard transformer pads or racks. The UL Listed designation supports safe integration in regulated environments.
Its K-Factor nonlinear design handles non-sinusoidal loads without overheating, preserving transformer life and voltage quality in data centers and automation cabinets. The vented XFMR construction improves heat dissipation under harmonic loads from drives and controllers, while the 30 kVA rating matches medium-scale workloads. UL Listing further supports compliance in critical infrastructure environments.
Expect a substantial footprint and weight (approx. 1093 lb). Plan for floor loading, appropriate lifting equipment, and clearances for ventilation. Ensure electrical clearances for the vented enclosure and access for routine maintenance. Leverage compatible mounting accessories and consider nearby cooling provisions to maintain optimal operating temperatures and reliability.
K-Factor nonlinear transformers are engineered to tolerate harmonic currents generated by modern drives and power electronics. This reduces stray heat, limits insulation stress, and maintains better voltage regulation under non-ideal conditions, delivering more consistent performance and longer service life for critical loads in manufacturing and automation environments.
By delivering stable voltage quality with reduced thermal stress and lower maintenance needs, the N48M28T3021CUHDI3 supports higher uptime and fewer derating events. The UL Listed protection adds audit confidence, while the robust vented design enables sustained operation in demanding environments, contributing to lower lifecycle costs and improved overall equipment effectiveness (OEE).