Eaton N48M28T30EESRLS43 K-Factor nonlinear transformer UL

Part Number: N48M28T30EESRLS43
Manufacturer
Eaton
Part number
N48M28T30EESRLS43

Quick Summary

Eaton N48M28T30EESRLS43 K-Factor nonlinear ventilated transformer conditions three-phase power for industrial systems. Engineers often struggle with harmonics, heat, and audible noise when scaling motor loads. It is UL Listed and features a NEMA 2 enclosure and a low sound profile near 43 dB, backed by a NEMA ST-20 test report and TP-1 efficiency considerations. This combination supports reliable, scalable power conditioning and simplifies panel integration for 480 V-to-208Y/120 V distributions in manufacturing, processing, and automation environments.

Product Information

Extended Description

N48M28T30EESRLS43 Eaton: Eaton K-Factor nonlinear ventilated transformer, KT-13 (3-phase), PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 208Y/120V, 150°C rise w/ 200°C insulation systeam, 30 kVA, EE, SR, LS43
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M28T30EESRLS43
UPC
786680102776
Product Length/Depth
16.5 in
Product Height
30 in
Product Width
23 in
Product Weight
383 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Low sound design equivalent to 43 dB, Certified Test Report of NEMA ST-20 Sound Level (on CMI style), NEMA TP-1 efficient
Coil material
Aluminum
Enclosure
NEMA 2
Wiring connection
283B
Type
Nonlinear, ventilated transformer
Frame
912B
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
60 Hz
Volt ampere rating
30 kVA
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
208 Y/120 V
Temperature rise
150 °C rise
Special features
Electrostatically shielded
Weathershield
WS38
Feature → Business Impact → Application: 30 kVA, three-phase transformer with 480 V primary and 208Y/120 V secondary delivers sufficient headroom for variable industrial loads, reducing voltage sag and ensuring equipment performance in manufacturing lines. Application: panel boards, controlled motor feeds, and distribution blocks benefit from predictable voltage with improved uptime. Feature → Business Impact → Application: K-Factor nonlinear ventilated design minimizes thermal buildup in high-harmonic environments, improving reliability and extending service life for aggressive factory loads. Application: machine tool cells and presses where power quality matters. Feature → Business Impact → Application: Two taps at +2.5% and four taps at -2.5% provide voltage regulation options to compensate for line drops, enabling smoother operation of sensitive drives and PLCs. Application: critical control panels and data-driven manufacturing setups. Feature → Business Impact → Application: NEMA 2 enclosure with aluminum coil and WS38 weather shield offers indoor dust and moisture protection, facilitating easier installation in typical plant indoor spaces. Application: retrofit projects and new builds in warehouses and assembly areas. Feature → Business Impact → Application: Low-noise design (43 dB) and EMI shielding reduce audible and electromagnetic interference, supporting compliant environments and worker comfort. Application: noise-sensitive production lines and clean rooms where compliance and concentration matter. Feature → Business Impact → Application: 150 °C rise and 200 °C insulation system provide robust thermal margins for peak loading and short-term overload events. Application: critical power paths in automation systems that demand rapid response without thermal derating.

Get a Quick Quote for a Eaton N48M28T30EESRLS43

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M28T30EESRLS43? Enquire Now

FAQs

Installation should be performed indoors within a NEMA 2 enclosure environment, with proper clearance for cooling. Use the 283B winding connection and plan for tap adjustments (+2.5% or -2.5%) to compensate voltage drop along feeders. The unit supports a 60 Hz supply and requires appropriate overcurrent protection and proper mounting to minimize vibration and noise transmission.
The K-Factor nonlinear design mitigates harmonics and thermal stress in high-load, variable-power applications, improving voltage regulation and efficiency. This translates to reduced transformer heating, longer component life, and improved availability of critical drives and PLCs in automated lines, while maintaining compliance with typical industrial power standards.
Yes. The N48M28T30EESRLS43 is UL Listed and equipped with a NEMA 2 enclosure for indoor use. It also features a low-noise design (~43 dB) and a certified NEMA ST-20 test report, ensuring compliance with common industrial safety and performance requirements in manufacturing and process environments.
The transformer provides two taps at +2.5% and four taps at -2.5%, enabling voltage regulation to maintain output near 208Y/120 V under voltage drop or spike conditions. This flexibility supports sensitive equipment like drives, controllers, and sensors, reducing the risk of misoperation due to voltage fluctuation.
With robust insulation (150 °C rise, 200°C insulation), aluminum coil construction, and an electrostatically shielded design, maintenance intervals are extended and diagnostic clarity improves. The combination of UL Listing, low noise, and efficient operation minimizes energy waste, delivering a favorable total cost of ownership through longer service life and reduced downtime in automation applications.