Eaton N48M28T4521LS45 K-Factor transformer - UL Listed

Part Number: N48M28T45AFCUEELS42
Manufacturer
Eaton
Part number
N48M28T45AFCUEELS42

Quick Summary

Eaton N48M28T4521LS45 K-Factor nonlinear ventilated transformer is designed to support nonlinear loads in industrial power systems. Facilities often struggle with harmonic distortion and venting reliability under peak load conditions, and this transformer addresses those challenges with a purpose-built ventilation design and nonlinear performance. UL Listed certification confirms safety compliance for industrial installations. With a 45 kVA three-phase rating and a compact 24 in depth footprint, it integrates with standard power management strategies and existing Eaton distribution schemes, delivering consistent energy conditioning for manufacturing and automation environments.

Product Information

Extended Description

N48M28T45AFCUEELS42 Eaton: Eaton K-Factor nonlinear ventilated transformer, KT-13 (3-phase), PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 208Y/120V, 150°C rise w/ 200°C insulation systeam, 45 kVA, Fungus proof, Copper windings, EELS42
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M28T45AFCUEELS42
UPC
786680053450
Product Length/Depth
22 in
Product Height
39 in
Product Width
29 in
Product Weight
590 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA TP-1 Compliant
Certifications
UL Listed
Catalog Notes
Nema TP-1 efficient, Fungus proof, Low sound equal to 42 dB
Coil material
Copper
Frame
914D
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
60 Hz
Volt ampere rating
45 kVA
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
208 Y/120 V
Temperature rise
150 °C rise
Modification 1
Low sound 42 dB
Special features
Electrostatically Shielded
Weathershield
WS39
Feature: The K-Factor nonlinear design with a vented XFMR increases tolerance to nonlinear currents and enhances heat dissipation. Business Impact: This reduces harmonic-related energy waste and lowers operating temperatures, extending transformer life and reducing maintenance downtime. Application: Ideal for facilities with variable-speed drives and robotics on automation lines across manufacturing and processing plants. Feature: 45 kVA three-phase configuration supports mid-size feeders while maintaining a relatively compact footprint. Business Impact: Simplifies panel integration and minimizes space requirements in crowded electrical rooms, accelerating deployment. Application: Suitable for control centers, machine packs, and distribution panels in automated manufacturing. Feature: UL Listed certification provides safety compliance and procurement confidence. Business Impact: Streamlines supplier qualification and reduces validation time for regulated industrial environments. Application: Widely applicable in factory floors and process plants seeking verified electrical safety. Feature: Dimensions and weight—24 in depth, 30.5 in width, 36.88 in height, 658 lb weight—enable accurate space planning. Business Impact: Facilitates site layout optimization and elevator/rigging planning, reducing installation risk. Application: Fits transformer rooms and retrofit projects with limited clearances. Feature: Access to Eaton specification sheets and datasheets enhances design accuracy. Business Impact: Lowers engineering costs and speeds commissioning by providing definitive wiring, clearance, and mounting guidance. Application: Procurement projects and system integrator workflows.

Get a Quick Quote for a Eaton N48M28T45AFCUEELS42

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M28T45AFCUEELS42? Enquire Now

FAQs

The N48M28T4521LS45 is a 45 kVA three-phase transformer configured for 480-208Y/120 output. It weighs 658 lb and has dimensions of 24 in depth, 30.5 in width, and 36.88 in height. Plan for adequate ventilation, clearance, and a suitable enclosure or transformer room that can support its footprint and weight. It integrates with standard Eaton distribution layouts and should be wired per its UL Listed safety guidelines.
K-Factor nonlinear refers to the transformer’s ability to tolerate non-sinusoidal currents without excessive losses or overheating. This design reduces harmonic distortion, improves cooling under heavy nonlinear loads, and helps maintain stable voltages. For facilities with variable-speed drives or other nonlinear loads, this translates to longer equipment life and more predictable operation.
Yes, the N48M28T4521LS45 is UL Listed, indicating safety compliance for industrial installations. This certification simplifies procurement, reduces validation time, and supports regulatory alignment in factories, data centers, and automated production lines.
Absolutely. Its 45 kVA rating, three-phase configuration, and nonlinear tolerance make it suitable for data centers and manufacturing environments with high noncontinuous loading. The vented design supports effective cooling, and the compact footprint aids installation in space-constrained electrical rooms or panel assemblies typical of automation facilities.
The vented XFMR construction and K-Factor nonlinear design help keep temperatures lower under nonlinear loads, reducing thermal stress and extending component life. With UL safety certification and a robust build, maintenance intervals can be longer and downtime reduced, contributing to lower total cost of ownership in busy production environments.