Eaton N48M28T75AFEELS47 Nonlinear ventilated transformer - UL

Part Number: N48M28T75AFEELS47
Manufacturer
Eaton
Part number
N48M28T75AFEELS47

Quick Summary

The Eaton nonlinear ventilated transformer is designed to deliver reliable, high‑quality power conditioning for three‑phase industrial systems. Operators often struggle with voltage drift, noise, and retrofit complexity when upgrading feeders, leading to downtime and higher costs. This unit is UL Listed with a NEMA 2 enclosure and fungus‑proof construction, ready for harsh environments. With a 75 kVA rating and a 480 V primary feeding 208Y/120 V secondary, it provides stable outputs across load changes. The integrated taps and robust insulation support precise voltage regulation and long‑term reliability, delivering business value through minimized outages and improved energy efficiency. These features align with safety, regulatory, and uptime priorities in modern facilities.

Product Information

Extended Description

N48M28T75AFEELS47 Eaton: Eaton K-Factor nonlinear ventilated transformer, KT-13 (3-phase), PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 208Y/120V, 150°C rise w/ 200°C insulation systeam, 75 kVA, Fungus proof, EE, LS47
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M28T75AFEELS47
UPC
786680103162
Product Length/Depth
23.42 in
Product Height
48.56 in
Product Width
28.22 in
Product Weight
775 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Low sound design equivalent to 47 dB, NEMA TP-1 efficient, Fungus proof
Coil material
Aluminum
Enclosure
NEMA 2
Wiring connection
283B
Type
Nonlinear, ventilated transformer
Frame
916A
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
60 Hz
Volt ampere rating
75 kVA
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
208 Y/120 V
Temperature rise
150 °C rise
Special features
Electrostatically shielded
Weathershield
WS19
Feature: K-Factor nonlinear ventilated design provides improved harmonic management and cooler operation. Business impact: reduces overheating risk and maintains output stability under nonlinear loads, extending equipment life and lowering maintenance costs. Application: ideal for data centers, machine shops, and process lines where harmonics and switching devices are common. Feature: Voltage taps: 2 at +2.5%, 4 at -2.5% for on-site regulation. Business impact: enables fast, accurate voltage matching, minimizing nuisance trips and inventory needs. Application: feeders delivering 480 V to 208Y/120 V end equipment in variable grid conditions. Feature: NEMA 2 enclosure and low sound design (~47 dB). Business impact: enables installation in damp, occupied, or noise-sensitive spaces without compromising reliability. Application: control rooms, panel houses, and production floors near personnel. Feature: 75 kVA rating with 150 °C rise and 200 °C insulation system, aluminum coil, frame 916A, wiring 283B. Business impact: robust thermal margin supports continuous operation under high loads, reducing insulation breakdown risk and downtime. Application: medium-size plant feeders and distribution banks in harsh environments. Feature: Fungus-proof construction and WS19 weather shield. Business impact: extended service life in humid or outdoor installations; regulatory compliance and reduced maintenance. Application: outdoor or semi-outdoor plant areas and damp facilities. Feature: Documentation and compatibility with Eaton’s Transformer Flex Center and catalog notes. Business impact: accelerates installation planning, simplifies lifecycle management, and improves post‑install support. Application: new builds and modernization projects across manufacturing and process industries.

Get a Quick Quote for a Eaton N48M28T75AFEELS47

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M28T75AFEELS47? Enquire Now

FAQs

This unit is a three‑phase transformer with a 480 V primary and a 208Y/120 V secondary, rated for 75 kVA and designed for 60 Hz operation. The configuration supports standard industrial power distribution with balanced phase loading and stable voltage under varying load. It also provides voltage stability under harmonic and switching conditions to protect sensitive equipment.
The transformer offers two taps at +2.5% and four taps at -2.5% for on-site regulation. Operators can select taps to compensate for voltage drop along feeders or input fluctuations, reducing voltage mismatch and avoiding nuisance trips in motor drives and control circuits. Proper tap selection supports consistent performance across load swings.
Yes. The transformer is UL Listed and housed in a NEMA 2 enclosure with fungus-proof design for damp locations. For outdoor or highly humid installations, WS19 weather shield provides additional protection, ensuring reliable operation and regulatory compliance in plant floors and switchgear areas.
The catalog notes indicate a low sound design of approximately 47 dB, which minimizes acoustic impact in occupied spaces and near control rooms. This helps meet site noise limits without extra attenuation, simplifying installation and reducing enclosure footprint in compact facilities.
Eaton provides a one-year warranty from installation or eighteen months from shipment, whichever occurs first (policy 25-000). Field support includes access to Eaton specification sheets and catalogs, plus guidance for compatibility with Eaton Transformer Flex Center for lifecycle and preventive maintenance planning.