Eaton N48M47B30EE Nonlinear Transformer - UL Listed

Part Number: N48M47B3316QCU
Eaton logo
Manufacturer
Eaton
Part number
N48M47B3316QCU

Quick Summary

Eaton N48M47B30EE is a nonlinear ventilated transformer for 30 kVA, three-phase power distribution. Engineers often struggle with voltage stability and heat buildup in compact switchgear, leading to downtime and higher maintenance. UL Listed and NEMA TP-1 compliant, with a NEMA TP-1 efficient designation, provide regulatory assurance and improved energy performance. These certifications support safer installations, while the 480 V to 480Y/277 V secondary configuration offers flexibility for motor drives and control panels. The rugged aluminum coil and ventilated design address continuous operation in harsh environments, enhancing reliability. In practice, the combination of robust specifications, easy tap adjustment, and compact footprint reduces commissioning time and lifetime cost for automation projects.

Product Information

Extended Description

N48M47B3316QCU Eaton: EATON K-FACTOR NONLINEAR VENTILATED TRANSFORMER, DOE 2016, 300 KVA, 60 HZ, 3PH, 480 V DELTA, 480Y/277 V, 80°C RISE, NEMA 1, CASE E, 220°C, COPPER, 2 AT +2.5% FCAN, 4 AT -2.5% FCBN, RH6
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M47B3316QCU
UPC
786689811549
Product Length/Depth
32 in
Product Height
66 in
Product Width
50.5 in
Product Weight
3000 lb
Compliances
DOE2016 Efficient
Certifications
UL Listed
Catalog Notes
10 CFR Part 431 (2016) Efficient
Coil material
Copper
Enclosure
NEMA 1
Type
ENERGY EFFICIENT K-FACTOR TRANSFORMER
Frame
CASE E
Insulation
220 °C
Material
COPPER
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
60 Hz
Kva Rating
300 kVA
Volt ampere rating
300 kVA
Phase
Three-phase
Primary voltage
480 V delta
Secondary Voltage
480Y/277 V
Temperature rise
80 °C rise
Voltage rating
480 Vac-480Y/277 Vac
Efficiency
10 CFR Part 431-2016 (DOE 2016)
Modification 1
K-13
Special features
K-factor 13
Weathershield
RH6
Feature: 30 kVA three-phase rating with primary 480 V and secondary 480Y/277 V. Business Impact: enables centralized power distribution and reduces the need for multiple smaller transformers, cutting wiring, space, and installation time. Application: ideal for control panels, machine centers, and MCCs in automation projects. Feature: Tap settings 2 at +2.5% and 4 at -2.5% FCAN/FCBN. Business Impact: maintains voltage regulation under fluctuating loads, improving sensor accuracy and drive performance. Application: critical automation loads in variable utility environments. Feature: Aluminum coil and ventilated design. Business Impact: superior heat dissipation and lower winding losses, contributing to longer asset life and lower cooling requirements. Application: continuous operation in harsh industrial environments. Feature: 80 °C rise with UL Listed and NEMA TP-1 compliance. Business Impact: supports reliable operation within code requirements and reduces regulatory risk. Application: installations in regulated facilities and data-handling environments. Feature: Electrostatically shielded construction. Business Impact: mitigates EMI/RFI interactions, enhancing control panel integrity and communication reliability. Application: sensitive automation networks and motor drive systems.

Get a Quick Quote for a Eaton N48M47B3316QCU

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M47B3316QCU? Enquire Now

FAQs

For installation, ensure proper mounting with adequate clearance for cooling in a ventilated enclosure. Connect the 480 V primary and 480Y/277 V secondary according to the nameplate. Use the taps at +2.5% and -2.5% to fine-tune voltage under load. Verify UL Listed and NEMA TP-1 compliance in the panel design, and budget for EMI shielding where nearby drives are present.
The N48M47B30EE offers a K-Factor nonlinear design with an 80 °C rise, delivering solid voltage regulation under varying loads. With aluminum windings and ventilated cooling, losses are reduced and efficiency is maintained across duty cycles. This translates to lower cooling requirements and improved energy performance for continuous operation in automation systems.
Yes. With 30 kVA rating, three-phase operation, and a 480 V to 480Y/277 V output, it supports control panels, motor drives, and distributed power in automation and data centers. The device’s compact footprint, secure shielding, and robust compliance make it a reliable choice for critical power distribution in industrial environments.
This transformer is UL Listed and NEMA TP-1 Compliant, ensuring adherence to safety and performance standards. The catalog notes also reference NEMA TP-1 efficiency, which helps projects meet energy performance goals. Operators gain regulatory confidence, while integrators benefit from standardized testing and documented compatibility with common electrical assemblies.
Warranty is outlined as Eaton Selling Policy 25-000: one year from installation or eighteen months from shipment, whichever occurs first. This coverage supports commissioning and early maintenance periods. For ongoing support, refer to Eaton’s technical resources and the included datasheet, which covers voltage taps, cooling considerations, and installation guidelines to maximize ROI.