Eaton N48M47F49CUEELS45 K-Factor Transformer - UL Listed

Part Number: N48M47F49CUEELS45
Manufacturer
Eaton
Part number
N48M47F49CUEELS45

Quick Summary

Eaton K-Factor nonlinear ventilated transformer enables efficient three-phase power conditioning for data centers and industrial facilities. It addresses voltage stability and harmonic distortion that challenge aging electrical systems with mixed loads. The unit is UL Listed, with a NEMA 2 enclosure and a low sound design that ease installation in crowded or noise-sensitive environments. Copper windings and configurable taps support precise voltage shaping at 480 V primary and 480Y/277 V secondary, under 60 Hz, delivering predictable performance and reduced heat losses. The robust mechanical design, 150 kVA rating, and 115 °C rise offer reliable service in demanding environments, while warranty terms—one year from installation or eighteen months from shipment—support total cost of ownership. This combination aligns with power management and infrastructure investment strategies.

Product Information

Extended Description

N48M47F49CUEELS45 Eaton: Eaton K-Factor nonlinear ventilated transformer, KT-13 (3-phase), PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 480Y/277V, 115°C rise, 150 kVA, Copper windings, EE, LS45
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M47F49CUEELS45
UPC
786680102882
Product Length/Depth
30.68 in
Product Height
62.18 in
Product Width
31.44 in
Product Weight
1935 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Catalog Notes
Low sound design equivalent to 45 dB, NEMA TP-1 efficient
Coil material
Copper
Enclosure
NEMA 2
Wiring connection
292A
Type
Nonlinear, ventilated transformer
Frame
918A
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
60 Hz
Volt ampere rating
150 kVA
Phase
Three-phase
Primary voltage
480 V
Secondary Voltage
480 Y/277 V
Temperature rise
115 °C rise
Special features
Electrostatically shielded
Weathershield
WS34
Feature: K-Factor nonlinear ventilated design with copper windings. Business Impact: Mitigates overheating and harmonic distortion from non-linear loads, improving voltage stability and extending insulation life. Application: Ideal for data centers and mixed-load industrial facilities where uptime and energy efficiency are critical. Feature: Adjustable taps with 2 at +2.5% and 4 at -2.5%. Business Impact: Enables precise voltage matching to 480 V and 480Y/277 V rails, reducing voltage drop and improving equipment performance under varying loads. Application: Installations subject to voltage drift or site upgrades. Feature: Copper windings and robust construction. Business Impact: Higher conductivity and lower copper losses yield better efficiency under full load and longer service life. Application: Continuous operation in harsh environments. Feature: NEMA 2 enclosure and 292A wiring connection. Business Impact: Simplifies indoor installation and compatibility with standard switchgear and terminal blocks. Application: Buildings and rooms with conventional electrical layouts. Feature: Low sound design (~45 dB) and 60 Hz operation with a 150 kVA rating. Business Impact: Reduces acoustic impact and supports reliable performance in shared spaces, improving total cost of ownership. Application: Data centers, hospitals, and manufacturing floors requiring quiet operation.

Get a Quick Quote for a Eaton N48M47F49CUEELS45

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M47F49CUEELS45? Enquire Now

FAQs

This unit is a three-phase transformer with 480 V primary and 480Y/277 V secondary, housed in a NEMA 2 enclosure. It uses a 292A wiring connection and a frame size of 918A. Plan for indoor installation with adequate clearance, ventilation, and accessibility for taps and connections. The unit weighs about 1935 lb, so mechanical mounting and crane access should be factored into the installation plan.
The K-Factor nonlinear design analyzes and accommodates harmonic currents, mitigating waveform distortion and reducing temperature rise under non-linear loading. This improves voltage regulation on the primary and secondary sides, leading to more stable downstream equipment operation and reduced cooling energy, which translates to lower operating costs in data centers and factories with mixed loads.
Yes. With a 150 kVA rating, 60 Hz operation, and robust copper windings, the N48M47F49CUEELS45 delivers reliable power conditioning essential for critical loads. Its UL Listed safety certification, low sound profile, and NEMA 2 enclosure support dependable operation in data centers and industrial environments where uptime and power quality are paramount.
The model ships UL Listed, confirming safety compliance. Other certifications such as CE, SIL, or IP ratings are not listed in the provided data. For region-specific requirements, consult Eaton’s datasheet and your local regulatory standards to determine if additional certifications are needed for your installation.
Warranty terms are one year from installation or eighteen months from shipment, whichever occurs first. Copper windings and the rugged NEMA 2 enclosure support long service life with proper maintenance. Plan for periodic inspection of connections, tap functionality, and cooling paths to sustain performance and minimize unplanned downtime.