Eaton N48M48T33EE K-Factor nonlinear transformer - KT-13

Part Number: N48M48T33EE
Manufacturer
Eaton
Part number
N48M48T33EE

Quick Summary

The Eaton N48M48T33EE K-Factor nonlinear transformer delivers harmonic-aware power conditioning for 3-phase distribution in demanding industrial facilities. In practice, engineers confront harmonics, voltage drop, and overheating under peak loads; this transformer is engineered to reduce those risks while maintaining voltage stability. For compliance, designs in this class are commonly evaluated against CE and UL standards, and many users also request IP ratings or SIL considerations in safety-critical areas; confirm certification with the manufacturer. The unit is a 300 kVA, 480 V primary, 480 delta secondary transformer with KT-13 3-phase configuration and adjustable taps, offering reliable integration into existing low-voltage power networks. This combination helps reduce energy waste and extend motor and switchgear life by maintaining clean, stable power.

Product Information

Extended Description

N48M48T33EE Eaton: Eaton K-Factor nonlinear ventilated transformer, KT-13 (3-phase), PV 480V, Taps: 2 at +2.5% /4 at -2.5%, SV 480 delta, 150°C rise w/ 200°C insulation systeam, 300 kVA, EE
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
N48M48T33EE
UPC
786680135200
Product Length/Depth
0.001 in
Product Height
0.001 in
Product Width
0.001 in
Product Weight
0.001 lb
Certifications
Contact Manufacturer
Volt ampere rating
300 kVA
Primary voltage
480 V
Secondary Voltage
480 delta
Feature: K-Factor nonlinear design reduces harmonic distortion and stabilizes voltage. Benefit: Improves power quality, protects sensitive loads, and reduces downstream overheating. Application: Use in 3-phase 480 V systems with significant harmonic content to extend motor life and minimize nuisance trips. Long-tail keywords: K-Factor transformer, harmonic mitigation, 3-phase transformer, power quality improvement. Feature: KT-13 3-phase configuration with 480 V primary and 480 V delta secondary. Benefit: Simplifies integration into existing low-voltage distribution boards and panels, reducing retrofit complexity. Application: Factory floor power distribution and machine cells requiring consistent phase alignment. Long-tail keywords: 3-phase transformer KT-13, 480 V delta, transformer in panel boards.Feature: Voltage-tap capability (+2.5% / -2.5%). Benefit: Maintains voltage regulation under varying load and supply conditions, reducing equipment stress. Application: Plants with fluctuating line voltage or simultaneous peak loads. Long-tail keywords: voltage regulation taps, +/- 2.5% taps, voltage stability.Feature: 300 kVA rating for scalable load centers. Benefit: Supports multiple machines or sub-feeds from a single transformer, simplifying installation and reducing equipment count. Application: Medium-to-large manufacturing lines and distribution zones. Long-tail keywords: 300 kVA transformer, medium-scale power distribution, robust industrial transformer.Feature: Ventilated construction with high insulation capacity (150°C rise / 200°C insulation system). Benefit: Enhanced cooling performance, higher short-term overload tolerance, and longer service life. Application: Environments with limited cooling or high ambient temperatures. Long-tail keywords: ventilated transformer, high-temperature insulation, cooling efficiency, lifecycle durability.Feature: Catalog alignment and compatibility with Eaton transformer resources. Benefit: Simplified procurement, faster specifications checks, and access to datasheets and training. Application: Engineering spec-writing, panel design, and maintenance planning. Long-tail keywords: Eaton transformer catalog, datasheet access, installation compatibility.

Get a Quick Quote for a Eaton N48M48T33EE

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton N48M48T33EE? Enquire Now

FAQs

Plan for proper mounting in a ventilated enclosure or dedicated transformer room, with clearances for cooling and service access. Ensure correct phase connection to the 480 V primary and 480 V delta secondary, and configure taps correctly to achieve the desired voltage regulation. Verify compatible bus configurations and follow manufacturer guidance for wiring, labeling, and protective devices.
The K-Factor nonlinear design targets harmonic currents by closely matching transformer thermal and magnetic response to non-linear loads. This reduces thermal rise in windings, minimizes voltage distortion, and improves overall power quality, which helps protect downstream motors and drives and reduces unwanted trips in high-harmonic environments.
This transformer is designed for robust industrial power distribution, with 3-phase 480 V operation and a 300 kVA rating. For safety-critical uses, verify certifications such as CE or UL and any SIL or IP requirements with Eaton prior to deployment. In critical environments, plan for proper enclosure protection, cooling, and maintenance access to sustain reliability.
The product specifies Certifications as Contact Manufacturer, so confirm with Eaton the exact standards applicable to your region and application. Typical considerations include CE for Europe, UL for North America, and any site-specific requirements for SIL, IP ratings, or environmental certifications. Always obtain official documentation before procurement.
The transformer’s harmonic mitigation and voltage regulation reduce equipment stress, lowering maintenance costs and extending motor and drive life. A 300 kVA rating provides scalable headroom for growth, potentially reducing the need for future transformer upgrades. Expect improved reliability, fewer unplanned outages, and lower energy losses in well-regulated 3-phase systems.