Eaton NT20P11F15CU Transformer - UL Listed K-Factor
Part Number: NT20P11F15CU
Quick Summary
Eaton NT20P11F15CU is a K‑Factor nonlinear ventilated transformer for critical loads in industrial power systems. Harmonics, heat buildup, and voltage sag can threaten uptime in demanding environments, and this unit is designed to address those challenges with a ventilated cooling path and copper windings. UL Listed certification confirms safety compliance, while the K‑13 design and electrostatic shielding help maintain voltage integrity under harmonic load. Designed for 240/480 V mains and 120/240 V secondary, it supports reliable distribution in control panels, machine rooms, and outdoor installations, delivering consistent performance with robust protection and long-term value for industrial automation applications.
Product Information
Extended Description
NT20P11F15CU Eaton: K-Factor Transformer, Ventilated, K-13, Single-phase, PV: 240 X 480V, Taps: 1 at +5% FCAN, 2 at -5% FCBN X 2 at +2.5% FCAN, 4 at -2.5% FCBN, SV: 120/240V, 115°C, 15 kVA , Cu windings , Elec. Shield, Frame: 816, uses WS11
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
NT20P11F15CU
UPC
786680024900
Product Length/Depth
18.39 in
Product Height
31.3 in
Product Width
22.89 in
Product Weight
273 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Coil material
Copper
Type
Ventilated transformer
Design
K-13
Frame
816
Tap size
1 at +5% FCAN, 2 at -5% FCBN x 2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
60 Hz
Kva Rating
15 kVA
Phase
Single-phase
Primary voltage
240 V, 480 V
Secondary Voltage
120/240 V
Temperature rise
115 °C rise
Special features
Electrostatically shielded
Weathershield
WS11
Commercial Distribution, Transformers, Volume 2, Tab 2
Eaton's Transformer Flex Center
Eaton Specification Sheet - NT20P11F15CU
The NT20P11F15CU uses a K‑Factor nonlinear ventilated transformer design to soften harmonic currents, improving reliability for sensitive equipment and reducing maintenance costs in high‑load environments. This feature translates to lower thermal stress and extended life for downstream components, especially in data centers or manufacturing lines where harmonics are common. The copper windings with an electrostatic shield provide efficient power transfer and enhanced fault isolation, improving safety margins and minimizing nuisance trips in protective relays during peak loading. With a 60 Hz frequency rating and a 15 kVA capacity, the transformer supports steady power for critical loads while enabling precise tapping (1 at +5%, 2 at −5% FCBN, 2 at +2.5%, 4 at −2.5%), allowing site‑level voltage regulation for variable supply conditions. This compatibility helps installers optimize panel layouts and reduce field adjustments during commissioning. The WS11 Weathershield and 816 frame deliver rugged outdoor suitability and straightforward mounting, enabling flexible installation in harsh environments without extra enclosure costs. The unit’s weight (273 lb) and compact footprint fit common racking and floor plans, simplifying modernization projects. UL Listed certification ensures compliance with electrical safety standards, while the durable construction minimizes downtime during routine maintenance and service life. In practice, this transformer supports efficiency gains, improved regulatory compliance, and meaningful reductions in total cost of ownership when deployed across distributed power architectures.
Get a Quick Quote for a Eaton NT20P11F15CU
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton NT20P11F15CU?
Enquire Now
FAQs
This transformer uses a frame 816 footprint with dimensions 18.39 in (L) x 22.89 in (W) x 31.3 in (H) and weighs 273 lb, which fits many standard industrial enclosures and panel layouts. When planning installation, confirm mounting clearance for ventilation and service access, and account for the WS11 weather shield if mounting outdoors.
The K‑13 nonlinear design limits harmonic distortion impact by shaping the transformer’s impedance under harmonic currents. This reduces overheating risk, stabilizes voltage for sensitive equipment, and lowers nuisance tripping in downstream protection systems, which translates into improved reliability for drives, PLCs, and other digitally controlled machinery.
Yes. The NT20P11F15CU features WS11 Weathershield and a ventilated construction to manage cooling in outdoor or harsh indoor settings. When mounting outdoors, ensure proper enclosure protection and space for ventilation; the weather shield helps resist moisture and contamination while preserving performance in variable ambient conditions.
Primary voltage options are 240 V and 480 V, with a secondary of 120/240 V. Tapping options include 1 at +5% FCAN, 2 at −5% FCBN, 2 at +2.5% FCAN, and 4 at −2.5% FCBN, enabling precise on-site voltage regulation to accommodate supply fluctuations and load changes without additional gear.
The unit carries Eaton’s one-year warranty from installation or eighteen months from shipment, whichever comes first. Eaton support provides parts, troubleshooting, and application guidance to ensure proper integration, safety compliance, and long‑term performance for industrial power distribution projects.