Eaton NT27M24S1516 Nonlinear Ventilated Transformer - UL Listed

Part Number: NT27M24S1516
Manufacturer
Eaton
Part number
NT27M24S1516

Quick Summary

Introducing the Eaton NT27M24S1516 nonlinear ventilated transformer, providing reliable power conditioning for control panels. Engineers often face voltage drift, heat buildup, and compliance gaps in panel power systems, which can cause downtime and reduced equipment life. UL Listed and NEMA TP-1 compliant with DOE 2016 Efficient design, this transformer also features electrostatic shielding and WS11 weathershield for rugged environments. For power management and distribution applications, it delivers efficiency gains, easier installation, and long-term reliability to OEMs and integrators alike.

Product Information

Extended Description

NT27M24S1516 Eaton: Eaton K-Factor nonlinear ventilated transformer, KT-13 (1-phase), PV 277V, Taps: 2 at +2.5% /4 at -2.5%, SV 240 delta, 150°C rise, 15 kVA, 16
Product Name
Eaton K-Factor nonlinear ventilated transformer
Catalog Number
NT27M24S1516
UPC
786680207396
Product Length/Depth
18.39 in
Product Height
31.3 in
Product Width
22.89 in
Product Weight
263 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
NEMA TP-1 Compliant
Certifications
UL Listed
Catalog Notes
DOE 2016 Efficient
Coil material
Aluminum
Frame
816
Tap size
2 at +2.5% FCAN, 4 at -2.5% FCBN
Frequency rating
50-60 Hz
Volt ampere rating
15 kVA
Phase
Single-phase
Primary voltage
277 V
Secondary Voltage
240 delta
Temperature rise
150 °C rise
Special features
Electrostatically shielded
Weathershield
WS11
Feature → Business Impact → Application: The NT27M24S1516 delivers 15 kVA in a compact 1-phase footprint, enabling efficient power conditioning for control panels and machine centers. This translates to improved voltage regulation under load swings and reduced heat, lowering cooling requirements and extending component life in automation racks. Application: factory floors, panel enclosures, and machine control cabinets seeking dependable, compact power conditioning. Feature → Business Impact → Application: 277 V primary to 240 V delta secondary configuration supports seamless integration with common panel boards, easing retrofit projects and new installations. Benefit: fewer wiring changes, faster commissioning, and improved compatibility with existing automation drives and sensors. Application: industrial automation systems and building automation panels. Feature → Business Impact → Application: Tap changes of 2 at +2.5% and 4 at -2.5% provide precise voltage regulation, reducing undervoltage and overvoltage events. Benefit: stabilized control signals, enhanced motor performance, and extended life for sensitive electronics. Application: critical process control, PLCs, and motor drives. Feature → Business Impact → Application: K-Factor nonlinear ventilated design with electrostatic shielding mitigates harmonic distortion and stray coupling, boosting power quality. Benefit: fewer EMI issues and safer operation for sensitive instrumentation. Application: data centers, CNC machines, and mixed-load facilities. Feature → Business Impact → Application: DOE 2016 Efficient performance, UL Listed and NEMA TP-1 compliance provide regulatory peace of mind and energy savings. Benefit: lower lifecycle costs, easier procurement approvals, and consistent performance in regulated environments. Application: energy-conscious facilities and OEM product lines. Feature → Business Impact → Application: WS11 Weathershield and aluminum coil construction enable outdoor and harsh-environment mounting with robust mechanical integrity. Benefit: reduced enclosure heating, longer service intervals, and reliable operation in outdoor panels. Application: outdoor substations, remote automation cabinets, and rugged industrial installations. Feature → Business Impact → Application: Frame 816 and a 263 lb mass offer a sturdy, compact footprint suitable for installation within standard electrical rooms and OEM enclosures. Benefit: simplified mounting, improved thermal management, and predictable heat dissipation. Application: OEM power distribution modules and retrofit projects.

Get a Quick Quote for a Eaton NT27M24S1516

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton NT27M24S1516? Enquire Now

FAQs

NT27M24S1516 is a 1-phase, 15 kVA transformer with a 277 V primary and a 240 V delta secondary. It supports standard industrial panel boards and automation equipment configured for these voltages. The unit uses taps for voltage adjustment (+2.5% / -2.5%), aiding compatibility with minor supply fluctuations. Ensure mounting fits the 18.39 in depth, 22.89 in width, and 31.3 in height footprint, and verify enclosure clearance for 263 lb weight.
The NT27M24S1516 provides two taps at +2.5% and four taps at -2.5%, allowing precise on-site voltage tuning. This capability minimizes under- or over-voltage events during motor starts, load changes, or supply swings, improving control accuracy and reducing thermal stress on downstream devices. Properly configuring taps during commissioning yields measurable improvements in equipment longevity and process stability.
Yes. The transformer features WS11 Weathershield protection and an aluminum coil, designed for rugged environments and outdoor mounting where applicable. Its electrostatic shielding further enhances EMI resilience in exposed locations. When installing outdoors, ensure appropriate enclosure rating and ventilation are maintained, and verify the installation site meets local electrical and ambient temperature requirements to maximize service life.
The NT27M24S1516 is UL Listed and NEMA TP-1 compliant, with DOE 2016 efficiency requirements. These certifications indicate the unit meets safety, reliability, and energy-use standards critical for industrial facilities, OEM equipment, and building automation projects. Compliance simplifies procurement, reduces risk in regulated environments, and supports lower operating costs through improved efficiency.
With a 15 kVA rating and DOE 2016 efficiency, the NT27M24S1516 reduces energy losses and cooling loads, delivering a favorable ROI in steady-state operations. The transformer is a passive device with minimal maintenance, mainly periodic inspection of connections, enclosure integrity, and thermal performance. Its robust construction (frame 816, aluminum coil, WS11) supports long service intervals in demanding facilities.