Eaton NXTS16245161 N-TB enclosure - IP66

Part Number: NXTS16245161
Manufacturer
Eaton
Part number
NXTS16245161

Quick Summary

Eaton NXTS16245161 provides rugged stainless steel enclosure protection for hazardous-area control panels in demanding industrial settings. Maintenance and safety in hazardous locations are challenging when access, sealing, and compliance conflict. It carries IP66 and NEMA 4X ratings, IECEx/ATEX approvals, and NEC hazardous-location ratings (Class I, Division 2; Zone 1) to support compliance across global projects. For stainless-steel enclosures and hazardous-location deployments, it simplifies procurement and installation while delivering durable, long-term protection. The 62 x 45 x 16 inch footprint accommodates large control components, with a single gland plate for neat wiring. Designed for 690 Vac/Vdc systems, it supports robust power distribution in demanding environments.

Product Information

Extended Description

NXTS16245161 Eaton: Eaton Crouse-Hinds series N-TB enclosure, 400A, 62" x 45" x 16" enclosure size, 506 mm horizontal fixing center, 450 mm vertical fixing center, With hinge, 316L stainless steel, 1 gland plate, 690 Vac/Vdc
Product Name
Eaton Crouse-Hinds series N-TB enclosure
Catalog Number
NXTS16245161
EAN
4251958137560
Product Length/Depth
450 mm
Product Height
620 mm
Product Width
160 mm
Product Weight
14.11 kg
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC IECEx/ATEX IEC
NEC hazardous rating
Class I, Division 2 Class I, Zone 1
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Material
316L stainless steel
Enclosure size
62" x 45" x 16"
Number of gland plates
1
Hinge
With hinge
316L stainless steel construction provides superior corrosion resistance, reducing replacement costs and downtime in chemical, coastal, and washdown environments. The material choice also delivers reliable structural integrity for long service life and predictable maintenance planning. Applications include chemical plants, offshore platforms, and food-and-beverage facilities where cleanliness and durability matter. Large footprint and standardized mounting centers streamline layout and installation. The enclosure measures 62" x 45" x 16" with 506 mm horizontal fixing centers and 450 mm vertical fixing centers, allowing space for drives, controllers, and terminal blocks. This reduces custom fabrications and accelerates panel assembly for new builds or retrofits. IP66 sealing and NEMA 4X protection deliver reliable performance in dusty, washdown, and outdoor environments. Coupled with 316L stainless steel, this enclosure maintains enclosure integrity while safeguarding equipment inside and operators outside. It’s suitable for outdoor substations and indoor production lines in hazardous-rated zones. Certified for hazardous locations, it carries IECEx/ATEX approvals and NEC Class I, Division 2; Zone 1 ratings, ensuring compliance across global sites. This reduces risk during audits and supports multi-region procurement strategies. High-voltage readiness is built in with a 690 Vac/Vdc rating, enabling safe power distribution in harsh environments. The with-hinge design and one gland plate aid serviceability, letting technicians access wiring quickly and re-seal without additional hardware or downtime. The enclosure supports efficient installation, reliable power distribution, and long-term lifecycle performance in demanding industrial settings.

Get a Quick Quote for a Eaton NXTS16245161

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton NXTS16245161? Enquire Now

FAQs

NXTS16245161 uses 316L stainless steel and a large 62 by 45 by 16 inch footprint, with horizontal fixing centers of 506 mm and vertical centers of 450 mm. This combination supports common control-cabinet layouts and simplifies retrofit projects. The one gland plate and hinge improve serviceability, reducing wiring time during installation and field upgrades.
Yes. The enclosure carries NEC hazardous-location ratings for Class I Division 2 and Zone 1, along with IECEx/ATEX approvals. It also features IP66 sealing and NEMA 4X protection, providing robust safety and compliance for hazardous-area installations across global sites.
NXTS16245161 is certified for hazardous locations (Class I, Division 2; Zone 1), IECEx/ATEX, NEC/CEC standards, NEMA 4X, and IP66. It also meets area-classification requirements for hazardous/classified locations, ensuring broad regulatory compatibility and field-ready compliance.
The hinged door provides quick and repeatable access to interior wiring, while the single gland plate streamlines cable entry and reduces the number of separate components needed during installation. Together, they shorten commissioning and routine maintenance windows, improve wiring organization, and lower labor costs during upgrades.
Yes. The enclosure is rated for 690 Vac/Vdc and is built with corrosion-resistant 316L stainless steel, IP66/NEMA 4X protection, and hazardous-location certifications. This enables safe, compliant integration of high-voltage power distribution within harsh environments such as chemical plants or offshore facilities.