Eaton NZMB1-A50 molded case circuit breaker - 25 kAIC
Part Number: NZMB1-A50
Quick Summary
NZMB1-A50 molded case circuit breaker from Eaton provides reliable distribution protection for industrial panels and machine enclosures. When panel downtime or nuisance trips threaten production, a robust thermal-magnetic trip reduces unplanned outages and equipment damage. Certification details should be confirmed with the manufacturer, but common benchmarks for industrial MCCBs include CE marking and enclosure IP ratings. This model's front-frame clamp mounting, three-pole NZM1 frame, and rocker-lever operation simplify installation, alignment, and maintenance in control panels. In practical terms, the device supports standard 40-50A settings and a 25 kAIC interrupt rating, enabling reliable protection across mid-size panels worldwide.
Product Information
Extended Description
NZMB1-A50 Eaton: Eaton Series NZM complete molded case circuit breaker, NZM1-frame, NZMB1, Thermal-magnetic trip type, 300-500A trip rating, Three-pole, 50A, 440 Vac, 25 kAIC, Distribution circuit protection, Rocker lever, 40-50A, Front frame clamp, 40-50A
Product Name
Eaton Series NZM complete molded case circuit breaker
Catalog Number
NZMB1-A50
EAN
4015082590765
Product Length/Depth
2.68 in
Product Height
5.71 in
Product Width
3.54 in
Product Weight
3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Amperage Rating
50 A
Voltage rating
440 Vac
Trip Type
T268
Circuit breaker type
NZMB1
Frame
NZM1
Class
Distribution circuit protection
Accessories
Rocker lever
Setting Range Ol Protector
40-50A
Short-circuit breaking capacity
25 kAIC
Interrupt rating
25 kAIC
Connection
Front frame clamp
Overload range
40-50A
Number of poles
Three-pole
Trip rating
300-500 A
Three-pole NZMB1 design with a 50 A rating and 440 Vac maximum allows compact, high-visibility protection for distribution circuits in industrial panels. The 25 kAIC short-circuit capacity translates into faster fault clearance and reduced arc damage, improving panel uptime in harsh plant environments. This configuration is ideal for machine drives, control panels, and process equipment where reliable protection and easy upstream coordination are critical. Thermal-magnetic trip type T268 delivers selective protection against overloads and short circuits, minimizing nuisance trips while preserving equipment life. In practice, operators gain fewer unplanned stops as the trip curve matches typical load profiles in manufacturing cells, enabling better downtime planning and maintenance scheduling. Front frame clamp mounting simplifies panel installation, reduces mounting hardware, and makes retrofits faster in spaces with limited depth. Paired with the rocker lever, technicians can verify trip status at a glance, accelerating commissioning and hands-on service. Setting range 40-50A and 300-500 A trip rating provide flexibility to accommodate evolving loads without swapping devices. The NZM1 frame footprint supports consistent mounting across the Eaton NZ-series, aiding standardization across multiple lines and lockers. Compliance considerations require confirmation with the manufacturer; however, this device aligns with common industrial protection practices for 440 Vac networks, where a 25 kAIC interrupt rating supports robust fault handling in medium-large panels.
Get a Quick Quote for a Eaton NZMB1-A50
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton NZMB1-A50?
Enquire Now
FAQs
NZMB1-A50 is a three-pole unit built on the NZM1 frame with front frame clamp mounting, designed for standard distribution panels and machine control enclosures. Its compact footprint (2.68 in depth, 5.71 in height, 3.54 in width) and 3 lb weight simplify installation in tight panels and retrofits. Ensure panel cutouts and busbar spacing match Eaton’s specifications.
NZMB1-A50 uses a thermal-magnetic trip (T268) that senses both overload currents and short-circuit surges, opening faster on severe faults while avoiding nuisance trips on ordinary load changes. The 50 A rating, 25 kAIC interrupt capacity, and three-pole arrangement help coordinate protection across phases, improving selectivity and limiting damage to downstream equipment.
Yes. Rated 440 Vac and capable of 25 kAIC short-circuit interruption, NZMB1-A50 is designed for mid-to-large industrial networks where robust protection and fast fault clearance are required. Its NZM1 frame and front-frame clamp support stable mounting in dense switchgear, while the 40–50 A setting range accommodates load growth without device replacement.
Compliances are designated by the manufacturer for this specific model, so confirm certification details with Eaton for your region. Typical documents to request include the official datasheet, installation manuals, and any CE marking or IP rating declarations applicable to your panel. The Eaton specification sheet NZMB1-A50 provides authoritative performance and mounting information.
Investing in NZMB1-A50 reduces downtime through reliable protection and predictable maintenance cycles. The unit's compact footprint, front-frame mounting, and rocker lever simplify commissioning, part availability, and field servicing. With a 25 kAIC interrupt rating, downstream equipment protection minimizes repair costs after faults, supporting a favorable total cost of ownership in industrial facilities.