Eaton NZMB2-A63-NA Molded Case Circuit Breaker - 25 kAIC
Part Number: NZMB2-A63-NA
Quick Summary
Eaton NZMB2-A63-NA molded case circuit breaker protects critical distribution circuits in industrial panels. Selecting the right protection device can be challenging when fault currents vary and space is limited. For reliable compliance, verify local approvals; this family commonly aligns with CE, UL, and IEC standards depending on region. The NZMB2-A63-NA integrates with NZM2 frames and front-screw wiring for straightforward panel retrofits. Use cases include distribution boards, machine control cabinets, and switchgear applications where reliable trip coordination and high fault-current protection are required. This combination delivers predictable protection performance, reduces downtime, and supports efficient maintenance planning across industrial facilities today. In practice, the installer gains faster commissioning and consistent protection alignment across fleets.
Product Information
Extended Description
NZMB2-A63-NA Eaton: Eaton Series NZM complete molded case circuit breaker, NZM2-frame, NZMB2, Fixed thermal, adjustable magnetic trip, 380-630A, Three-pole, 63A, 440 Vac, 25 kAIC, Distribution circuit protection, 50-63A, 380-630A delayed, Front screw, 50-63A
Product Name
Eaton Series NZM complete molded case circuit breaker
Catalog Number
NZMB2-A63-NA
EAN
4015082692117
Product Length/Depth
4.05 in
Product Height
7.24 in
Product Width
4.13 in
Product Weight
4.1 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Amperage Rating
63 A
Voltage rating
440 Vac
Trip Type
T185
Circuit breaker type
NZMB2
Frame
NZM2
Class
Distribution circuit protection
Accessories
Rocker lever, motor drive
Adjustment range short-circuit release
380-630A delayed
Setting Range Ol Protector
50-63A
Short-circuit breaking capacity
25 kAIC
Interrupt rating
25 kAIC
Connection
Front screw
Overload range
50-63A
Number of poles
Three-pole
Trip rating
380-630 A
The NZMB2-A63-NA uses the NZM2 frame, offering a compact molded case design that combines solid current handling with a lightweight footprint. This helps electrical teams fit protection devices into tighter panel layouts while maintaining robust distribution circuit protection performance. With an amperage rating of 63 A and a 440 Vac operating voltage, it protects medium to large distribution circuits in three-phase services. Its 25 kAIC short-circuit breaking capacity minimizes fault damage and supports higher fault current environments common in industrial facilities. The trip assembly features fixed thermal and adjustable magnetic trip (T185). The setting range Ol Protector is 50–63 A, and the delayed short-circuit release covers 380–630 A, enabling precise coordination with upstream devices and reduced nuisance trips. Front screw connection simplifies installation and maintenance, enabling easier retrofits in existing panels where rear access is limited. The three-pole configuration ensures balanced protection across all phases, essential for motor and process loads in manufacturing environments. Accessories such as a rocker lever and a motor drive option enhance usability and remote control integration in machine control cabinets. This supports faster commissioning, safer operation, and compatibility with Eaton's control schemes. Designed for distribution circuit protection with a 4.05 in depth and 7.24 in height, the unit weighs 4.1 lb, making it straightforward to handle during installation while maintaining a sturdy mechanical profile.
Get a Quick Quote for a Eaton NZMB2-A63-NA
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton NZMB2-A63-NA?
Enquire Now
FAQs
Installers should verify panel space and alignment with the NZM2 footprint, then mount the device in the panel using the front-screw terminals. Ensure correct phase orientation and secure busbar connections before energizing. Follow standard electrical codes and manufacturer guidance for terminal torque and wiring practices to achieve reliable contact and maintenance access.
Key specs include a 63 A amperage rating, 440 Vac voltage rating, and 25 kAIC short-circuit breaking capacity. The unit is a three-pole NZMB2 type within the NZM2 frame, with a fixed thermal and adjustable magnetic trip (T185). OL protector setting ranges from 50–63 A, and a delayed release covers 380–630 A, with front-screw connections for easy wiring.
Yes. The three-pole design supports balanced three-phase protection required in motor control centers, and accessories such as a rocker lever and motor drive improve control integration. Its high breaking capacity and reliable trip coordination help protect motors and downstream equipment in MCCs and switchgear assemblies.
Compliances are listed as manufacturer-verified; verify region-specific approvals with Eaton. Common certifications to confirm by region include CE, UL, and IEC standards, especially for panel installations in regulated markets. Always check the latest Eaton documentation or contact the manufacturer for the exact approvals on this model.
The product carries Eaton’s warranty policy 25-000, offering one year from the date of installation or eighteen months from the date of shipment, whichever occurs first. Field support, part availability, and technical guidance are available through Eaton’s distributor network and Eaton’s technical support resources.