Eaton NZMH2-A160-NA Molded Case Breaker - 85-150 kAIC

Part Number: NZMH2-A160-NA
Manufacturer
Eaton
Part number
NZMH2-A160-NA

Quick Summary

The Eaton NZMH2-A160-NA molded case breaker provides reliable overcurrent protection for industrial power distribution and motor-control panels. Engineers often struggle to coordinate adjustable thermal and magnetic trips across fluctuating loads, risking nuisance trips or under-protection. This unit uses a NZM2 frame with three poles, a 160 A rating, and 690 Vac / 750 Vdc compatibility, delivering 85–150 kAIC interrupt capacity. Compliance details (such as CE/UL markings) are provided by the manufacturer; review the datasheet for exact certifications. With front screw connections and optional accessories like a rocker lever or motor drive, installation is fast and maintenance is predictable, supporting distribution protection in demanding environments. This combination translates to reduced downtime, safer operation, and more efficient spare-part planning for your facility.

Product Information

Extended Description

NZMH2-A160-NA Eaton: Eaton Series NZM complete molded case circuit breaker, NZM2-frame, NZMH2, Adj. thermal, adj. magnetic trip, 960-1600A delayed, Three-pole, 160A, 690 Vac, 750 Vdc, 85-150 kAIC, Distribution circuit protect., 125-160A, Front screw, 125-160A
Product Name
Eaton Series NZM complete molded case circuit breaker
Catalog Number
NZMH2-A160-NA
EAN
4015082692377
Product Length/Depth
5.9 in
Product Height
7.7 in
Product Width
4.1 in
Product Weight
4.1 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Amperage Rating
160 A
Voltage rating
690 Vac, 750 Vdc
Trip Type
Adjustable thermal, adjustable magnetic
Circuit breaker type
NZMH2
Frame
NZM2
Class
Distribution circuit protection
Accessories
Rocker lever, motor drive
Setting Range Ol Protector
125-160A
Short-circuit breaking capacity
150 kAIC
Interrupt rating
85-150 kAIC
Connection
Front screw
Overload range
125-160A
Number of poles
Three-pole
Trip rating
960-1600 A delayed
Adjustable thermal and magnetic trip allows precise protection for motor loads and process equipment, reducing nuisance trips and extending equipment life. This precision translates into measurable efficiency gains on manufacturing lines and safer operation in critical processes. The NZM2 frame compatibility and front screw terminals simplify installation and future maintenance, lowering field labor costs and improving reliability in panel assemblies. The 690 Vac / 750 Vdc rating supports mixed AC/DC networks commonly found in industrial facilities, while the 960-1600 A delayed trip helps manage inrush during motor startup without compromising protection. With a short-circuit breaking capacity of 150 kAIC and an interrupt rating of 85-150 kAIC, this device provides robust fault-current protection in dense switchboards. Accessories such as rocker lever and motor drive, plus a 125-160 A setting range, offer flexible integration for diverse applications and easier retrofit. A one-year warranty (or eighteen months from shipment) reduces procurement risk while ensuring reliable service life for critical protection gear.

Get a Quick Quote for a Eaton NZMH2-A160-NA

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton NZMH2-A160-NA? Enquire Now

FAQs

For a three-pole installation, ensure front screw terminals are accessible and oriented for safe connections. The NZMH2-A160-NA uses the NZM2 frame and supports a 125-160 A setting range with 690 Vac / 750 Vdc ratings. Verify panel space, torque requirements, and compatibility with rocker lever or motor drive accessories to optimize installation time and future maintenance.
This breaker is rated for 160 A with 690 Vac and 750 Vdc. It features adjustable thermal and magnetic trip, a setting range of 125-160 A, and a delayed trip of 960-1600 A. The short-circuit breaking capacity is up to 150 kAIC, with an interrupt rating between 85-150 kAIC, and front screw connections for straightforward wiring.
Yes, the unit supports 750 Vdc applications and is suitable for distribution panels and motor control centers requiring reliable protection with adjustable trip settings. Its NZM2 frame and three-pole design make it a strong choice for industrial power networks that mix AC and DC loads, delivering consistent protection across critical lines.
Compliances are provided by the manufacturer; consult the Eaton datasheet or contact Eaton directly for exact certifications such as CE or UL markings. The NZMH2-A160-NA is designed to align with typical industry protection standards, with detailed compliance documentation available from the manufacturer.
The adjustable trip reduces nuisance trips and allows load-specific protection, improving equipment longevity and uptime. Front screw connections facilitate quicker field servicing, while accessories like rocker lever and motor drive simplify integration. The device’s robust interrupt ratings help minimize panel damage during faults, contributing to lower maintenance costs and a faster return on investment.