Eaton NZMH2-A20 Molded Case Breaker - Adjustable Trip
Part Number: NZMH2-A20
Quick Summary
NZMH2-A20 molded case circuit breaker protects industrial control panels from overload and short circuits. For engineers facing nuisance trips or motor-start peaks, precise setting ranges and reliable trip coordination reduce downtime and extend equipment life. Compliance details should be confirmed with the manufacturer, as indicated in the specifications, to ensure alignment with project standards. Built on the NZM2 frame with a three-pole configuration, this device supports robust distribution circuit protection while enabling flexible integration into motor drives and panel assemblies. In practice, the NZMH2-A20 offers a balance of protection, installation convenience, and total cost of ownership advantages for industrial automation projects.
Product Information
Extended Description
NZMH2-A20 Eaton: Eaton Series NZM complete molded case circuit breaker, NZM2-frame, NZMH2, Adj. thermal, Adj. magnetic trip, Three-pole, 20A, 750 Vdc, Dist. circuit protection, Rocker lever, motor drive, 15-20A, 350-350A delayed, 15-20A
Product Name
Eaton Series NZM complete molded case circuit breaker
Catalog Number
NZMH2-A20
EAN
4015082812812
Product Length/Depth
4.05 in
Product Height
7.24 in
Product Width
4.13 in
Product Weight
4.1 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Amperage Rating
20 A
Voltage rating
690 Vac, 750 Vdc
Trip Type
Adjustable thermal, adjustable magnetic
Circuit breaker type
NZMH2
Frame
NZM2
Class
Distribution circuit protection
Accessories
Rocker lever, motor drive
Adjustment range short-circuit release
350-350A delayed
Setting Range Ol Protector
15-20A
Short-circuit breaking capacity
150 kAIC
Interrupt rating
85-150 kAIC
Connection
Front screw
Overload range
15-20A
Number of poles
Three-pole
Feature → Business Impact → Application: The NZMH2-A20 provides adjustable thermal and magnetic trip with a 20 A rating, enabling precise protection settings that minimize nuisance shutdowns while safeguarding motors and circuits in automation panels. This translates to reduced downtime and predictable maintenance planning for panel builders and end users, especially in applications with variable loads. Feature → Business Impact → Application: The device uses the NZM2 frame and front screw connections, improving compatibility with standard control panels and simplifying retrofit projects. For installers, this means faster wiring, cleaner panel layouts, and easier future upgrades in motor drives and distribution boards. Feature → Business Impact → Application: Short-circuit breaking capacity of up to 150 kAIC and an interrupt rating of 85–150 kAIC provide robust fault isolation for high-energy processes, supporting compliance with critical safety standards while protecting upstream equipment. Feature → Business Impact → Application: The adjustable setting range (15–20 A) and 350 A delayed release option help coordinate motor startups and protect power electronics, delivering smoother commissioning and reduced wear on contactors and cables. Feature → Business Impact → Application: Rocker lever and motor drive accessories offer ergonomic operation and seamless integration with drive systems, improving field reliability and sparing engineers from custom accessories. Feature → Business Impact → Application: With a three-pole design and front-access installation, the NZMH2-A20 supports compact, scalable panel layouts, enabling efficient distribution circuit protection across multi-axis machines and automation racks. Real-world context: industrial facilities benefit from clear protection parameters, fast fault clearance, and predictable lifecycle costs when using standardized components from the NZM2 family.
Get a Quick Quote for a Eaton NZMH2-A20
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton NZMH2-A20?
Enquire Now
FAQs
NZMH2-A20 uses a front screw connection on a three-pole NZM2 frame, making it straightforward to drop into standard distribution panels and motor drive assemblies. Its compact dimensions and chassis compatibility support quick retrofits and clean panel wiring, reducing installation time and potential wiring errors.
The device features an adjustable thermal and magnetic trip with a setting range of 15–20 A and a delayed 350 A short-circuit release, allowing precise coordination with motors and drives. This enables optimized protection while accommodating startup surges in automation systems.
Yes. With a three-pole configuration, motor drive compatibility, and a high short-circuit capacity (up to 150 kAIC), the NZMH2-A20 is well-suited for protecting motor drives and associated power electronics in automated equipment and panels.
Compliance details are listed as ‘Contact Manufacturer’ in the spec. Users should verify current certifications and regulatory alignment (CE, IP, SIL where applicable) directly with Eaton to ensure project-specific compliance.
Eaton’s policy provides a one-year warranty from installation or eighteen months from shipment, whichever comes first. For spare parts, replacements, and technical support, contact Eaton or authorized distributors to maintain uptime and protect long-term ROI.