The Eaton NZMH2-A80-BT-NA molded case circuit breaker protects distribution circuits in industrial control panels. Engineers often struggle with nuisance trips and poor protection coordination that disrupt uptime, especially in compact panel spaces. UL Listed certification underpins safety and reliability, with a 690 Vac / 750 Vdc rating and an 85–150 kAIC interrupt capacity for demanding industrial environments. This model combines precise settings with a robust NZM2 frame, delivering reliable protection while supporting efficient maintenance and scalable protection density for growing electrical rooms.

Product Information

Extended Description

NZMH2-A80-BT-NA Eaton: Eaton Series NZM complete molded case circuit breaker, NZM2-frame, NZMH2, Adj. thermal, adj. magnetic trip, Three-pole, 80A, 690 Vac, 750 Vdc, 85-150 kAIC, Box, Distribution circuit protect., 63-80A, Front frame clamp, 63-80A
Product Name
Eaton Series NZM complete molded case circuit breaker
Catalog Number
NZMH2-A80-BT-NA
EAN
4015081074501
Product Length/Depth
4.05 in
Product Height
7.24 in
Product Width
4.13 in
Product Weight
6.15 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Certifications
UL Listed
Amperage Rating
80 A
Voltage rating
690 Vac, 750 Vdc
Trip Type
Adjustable thermal, adjustable magnetic
Circuit breaker type
NZMH2
Terminals
Box
Frame
NZM2
Class
Distribution circuit protection
Accessories
Rocker lever, motor drive
Adjustment range short-circuit release
480-800A delayed
Setting Range Ol Protector
63-80A
Short-circuit breaking capacity
150 kAIC
Interrupt rating
85-150 kAIC
Connection
Front frame clamp
Overload range
63-80A
Number of poles
Three-pole
Feature: 80 A amperage rating with 63-80 A overload range. Benefit: Enables precise protection coordination for motor loads and feeders, reducing false trips and extending equipment life. Application: Distribution panels in manufacturing lines needing tight current control. Feature: 690 Vac / 750 Vdc voltage rating. Benefit: Supports multi-source power environments and DC links without swapping devices. Application: Industrial control panels and DC bus sections. Feature: Adjustable thermal and adjustable magnetic trip. Benefit: Improves selective coordination and fault clearance, lowering downtime and maintenance costs. Application: Equipment with varying startup currents and motor loads. Feature: NZMH2 three-pole frame NZM2 with front frame clamp terminals. Benefit: Simple, secure mounting and wiring in congested enclosures, reducing installation time. Application: New builds and panel refurbishments with limited mounting space. Feature: Short-circuit release range 480-800 A delayed and overload setting 63-80 A. Benefit: Flexible fault protection and coordination for modern industrial circuits, enabling fast yet controlled disconnection. Application: Heavy machinery and conveyor systems requiring high fault current handling. Feature: Accessories include rocker lever and motor drive. Benefit: Improves operation ergonomics and remote motor control integration. Application: Panels with motorized disconnects and ergonomic accessibility needs. Feature: Warranty and compliance notes — 1 year minimum warranty; Compliances: Contact Manufacturer; Certifications: UL Listed. Benefit: Clear support criteria and regulatory alignment for procurement and long-term service.

Get a Quick Quote for a Eaton NZMH2-A80-BT-NA

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton NZMH2-A80-BT-NA? Enquire Now

FAQs

For installation, use the front frame clamp terminals to secure wiring and ensure proper alignment with the NZM2 frame. Verify panel space for a three-pole device and position the breaker to allow accessibility for manual operation and routine testing. Confirm torque per manufacturer recommendations during assembly and ensure routing minimizes heat buildup and vibration in the enclosure.
The device offers adjustable thermal and magnetic trip settings to tailor overcurrent protection to specific loads. By coordinating with feeder protections and motor starting currents, the breaker reduces nuisance trips and improves selective clearance. This is particularly beneficial in mixed-load panels where motors, drives, and resistive loads share the same distribution circuit.
Yes. The NZMH2-A80-BT-NA is rated for 690 Vac and 750 Vdc, providing three-pole protection with a robust interrupt capacity. The front-frame clamp terminals and NZM2 frame support reliable mounting in compact panels, making it suitable for mixed high-voltage AC and DC distribution arrangements in industrial settings.
The product carries UL Listed certification, affirming compliance with essential safety standards for electrical protection devices. While the data specifies UL Listed status, always verify regional regulatory requirements with the manufacturer, as additional certifications or markings may be needed to meet local codes and customer procurement policies.
The NZMH2-A80-BT-NA combines rugged protection with adjustable trip settings, enabling precise coordination and reducing downtime due to nuisance tripping. Its 85–150 kAIC interrupt capacity and front-frame mounting simplify maintenance and replacement, while the 1-year warranty (18 months from shipment) provides early-life support, supporting lower lifecycle costs and predictable maintenance budgeting.