Eaton NZMH3-VE600-NA Molded Case Breaker - UL Listed

Part Number: NZMH3-VE600-NA
Manufacturer
Eaton
Part number
NZMH3-VE600-NA

Quick Summary

NZMH3-VE600-NA molded case circuit breaker is Eaton's reliable overcurrent protection solution for industrial power distribution. This device helps engineers prevent costly outages in control panels and feeders by delivering precise, coordinated protection. UL Listed certification supports compliance within safety programs and panel approvals, reinforcing risk management and project timelines. With a 600 A rating and 600 Vac operating capability, it aligns with demanding facility requirements while enabling selective protection and generator protection strategies. The front screw connection and three-pole NZM3 frame simplify installation in compact panel designs, helping maintenance teams shorten wiring time and reduce spare-part inventory, ultimately improving total cost of ownership and uptime.

Product Information

Extended Description

NZMH3-VE600-NA Eaton: Eaton Series NZM complete molded case circuit breaker, NZM3-frame, NZMH3, Thermal-magnetic trip, 450-4200A delayed, 1200-4800A delayed, Three-pole, 600A, 600 Vac, 100 kAIC at 480 Vac, Selective and gen. protect., Front screw, 300-600A
Product Name
Eaton Series NZM complete molded case circuit breaker
Catalog Number
NZMH3-VE600-NA
EAN
4015082693374
Product Length/Depth
6.53 in
Product Height
6.53 in
Product Width
6.53 in
Product Weight
5.5 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed
Amperage Rating
600 A
Voltage rating
600 Vac
Trip Type
T268
Circuit breaker type
NZMH3
Frame
NZM3
Class
Selective and generator protection
Accessories
Rocker lever, motor drive
Setting Range Ol Protector
300-600A
Short-circuit breaking capacity
150 kAIC
Interrupt rating
100 kAIC at 480 Vac
Connection
Front screw
Overload range
300-600A
Number of poles
Three-pole
Trip rating
450-4200 A delayed, 1200-4800 A delayed
600 A, 600 Vac capability provides robust protection for high-demand feeders, reducing nuisance trips and enabling reliable power distribution in manufacturing environments. This feature translates into increased equipment uptime and safer panel operation, especially where motors and drives demand surge currents. The thermal-magnetic trip (T268) delivers fast, coordinated protection with upstream devices, minimizing disruptive outages and enabling precise fault isolation at the source. Short-circuit breaking capacity of 150 kAIC and an interrupt rating of 100 kAIC at 480 Vac equip the NZMH3-VE600-NA to withstand large fault currents, enhancing safety and reducing downstream damage in critical circuits. A front screw connection enables straightforward wiring and dependable connections during installation and maintenance, reducing labor costs and escalation risk in refits. The three-pole NZMH3 frame (NZM3) supports standard three-phase configurations, simplifying integration across common industrial power architectures. Class “Selective and generator protection” ensures proper coordination with auxiliary protections and generator feeders, improving system reliability and reducing unnecessary trips. Accessories such as rocker lever and motor drive options expand control and automation compatibility, enabling plug-and-play enhancements without major rework. In real-world panel builds, these features translate to faster commissioning, easier spare-part planning, and lower total cost of ownership.

Get a Quick Quote for a Eaton NZMH3-VE600-NA

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton NZMH3-VE600-NA? Enquire Now

FAQs

Installation uses the front screw connections on a three-pole NZM3 frame. Mount the unit in a compatible panel, align with adjacent devices, and connect conductors per Eaton’s installation guidelines documented in the NZMH3-VE600-NA specification sheet. The UL Listed unit simplifies certification during panel commissioning, and the rocker lever accessory can aid reset operations after trips.
Key specs include an Amperage Rating of 600 A, Voltage Rating of 600 Vac, a Thermal-Magnetic trip (T268), Short-Circuit Breaking Capacity of 150 kAIC, Interrupt Rating of 100 kAIC at 480 Vac, and a Front Screw connection. It is a Three-Pole device within the NZM3 frame and supports selective and generator protection configurations.
Yes. The NZMH3-VE600-NA is designed for selective and generator protection, providing coordinated tripping with upstream devices and safe isolation of generator feeders. This makes it well-suited for applications where precise protection and minimal downstream disruption are critical.
The NZMH3-VE600-NA is UL Listed, ensuring compliance with recognized safety standards for industrial electrical equipment. This certification supports panel approvals and reduces risk during commissioning and audits.
Common applications include control panels, power distribution blocks, and high-demand industrial feeders in manufacturing. The device’s 600 A / 600 Vac rating, high fault-current capacity, and three-pole configuration make it suitable for motors, drives, and generator-connected circuits requiring reliable selective protection.