Eaton NZMN2-4-A300 Molded Case Circuit Breaker - UL Listed

Part Number: NZMN2-4-A300
Manufacturer
Eaton
Part number
NZMN2-4-A300

Quick Summary

The Eaton NZMN2-4-A300 molded case circuit breaker protects power distribution in industrial panels, delivering reliable, scalable fault protection. Engineers often contend with nuisance trips and space-constrained enclosures; this MCCB provides consistent coordination and fast response to overloads. UL Listed, IEC Rated, and CSA Certified, it meets top-tier safety and regulatory requirements across diverse installations. With a four-pole design and a 300 A rating, it supports modern three-phase systems while enabling straightforward upgrades. Its compact footprint and standardized dimensions streamline panel integration, replacement, and serviceability, reducing downtime and total cost of ownership while maintaining rigorous protection standards for critical automation assets.

Product Information

Extended Description

NZMN2-4-A300 Eaton: Eaton Series C molded case circuit breaker NZM2 Mccb Tm 300 A , 4Pole Adj Therm Setting (IEC Only)
Product Name
Eaton Series C molded case circuit breaker
Catalog Number
NZMN2-4-A300
UPC
786689165642
Product Length/Depth
5.5 in
Product Height
5.9 in
Product Width
5.9 in
Product Weight
5.2 lb
Certifications
UL Listed IEC Rated CSA Certified
Type
Series C
Amperage Rating
300 A
Trip Type
T264
Circuit breaker type
NZMN2
Class
Distribution circuit protection
Number of poles
Four-pole
Feature provides robust, four-pole protection with a 300 A rating, delivering complete isolation in three-phase systems and simplifying neutral handling. Business impact is improved safety, reduced arc-flash risk, and easier coordination with downstream protection devices, enabling efficient panel design and reliable startup in manufacturing lines. This is particularly applicable in industrial power distribution where space is at a premium and precise trip behavior is required. Feature1: Adjustable thermal trip setting (IEC only) enhances protection tuning and selectivity, reducing nuisance trips while preserving equipment life. Business impact: optimized protection curves and longer equipment life, translating to lower maintenance costs and less unscheduled downtime. Application: IEC-operated facilities requiring tuned overload protection. Feature2: UL Listed, IEC Rated, CSA Certified ensures regulatory compliance and market acceptance. Business impact: faster procurement cycles, easier approvals, and reduced audit risk across global sites. Application: regulated industries and multinational deployments. Feature3: Series C architecture provides a proven, modular protection platform with reliable performance. Business impact: predictable trip characteristics, repeatable maintenance outcomes, and simplified spare-part planning. Application: standard panel-builds and retrofit projects. Feature4: 5.5 in depth, 5.9 in height and width, 5.2 lb weight offer a compact footprint for tight panel spaces. Business impact: higher packing density, easier retrofits, and reduced enclosure modification. Application: facility upgrades and new installations with space constraints. Feature5: Four-pole construction supports full neutral isolation, improving safety and system integrity. Business impact: enhanced fault containment and simpler wiring schemes, reducing commissioning time. Application: three-phase systems with neutral loads in manufacturing and data centers.

Get a Quick Quote for a Eaton NZMN2-4-A300

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton NZMN2-4-A300? Enquire Now

FAQs

NZMN2-4-A300 is a four-pole MCCB with a 5.5 in depth and 5.9 in height and width, designed for standard panel mounting. Use the required mounting hardware and ensure space for the four-pole wiring and neutral connections. Refer to the Eaton spec sheet for exact mounting clearances and terminal torque values.
The device is UL Listed, IEC Rated, and CSA Certified, ensuring compliance with North American and international safety and performance standards. These certifications streamline procurement, shorten approval cycles, and support regulatory compliance in diverse facilities.
Yes. The four-pole design provides complete isolation of all poles, including the neutral, which is essential for safe operation and proper fault clearance in systems with neutral loads or ungrounded configurations.
T264 refers to a thermal-magnetic trip characteristic that provides overload and short-circuit protection. The unit also offers an adjustable thermal setting in IEC-based applications to optimize coordination with downstream devices.
The compact 5.2 lb package, standard dimensions, and four-pole protection simplify installation and retrofits, reducing panel modification time and inventory needs. UL/IEC/CSA certifications reduce compliance risk, while reliable protection minimizes unplanned downtime and extends equipment life.