Eaton NZMN2-A80-NA Molded Case Circuit Breaker - UL Listed
Part Number: NZMN2-A80-NA
Quick Summary
NZMN2-A80-NA molded case circuit breaker provides reliable overload protection for electrical distribution panels. Engineers seek devices that prevent nuisance trips while simplifying installation, and this unit delivers with a thermal-magnetic trip and a straightforward screw connection. This product carries UL Listed certification and uses the NZM2 frame for consistent performance in distribution applications. For panel builders and maintenance teams, the 80 A rating, 690 Vac / 750 Vdc capability, and 50 kAIC interrupt rating translate into safer, more compliant switchgear and faster commissioning. By aligning with standard accessories like a rocker lever and motor drive option, it reduces stocking complexity and supports scalable protection across industrial environments.
Product Information
Extended Description
NZMN2-A80-NA Eaton: Eaton Series NZM complete molded case circuit breaker, NZM2-frame, NZMN2, Thermal-magnetic trip type, Three-pole, 80A, 690 Vac, 750 Vdc, 50 kAIC, Distribution circuit protection, Rocker lever, motor drive, Screw
Product Name
Eaton Series NZM complete molded case circuit breaker
Catalog Number
NZMN2-A80-NA
EAN
4015082692230
Product Length/Depth
4.05 in
Product Height
7.24 in
Product Width
4.13 in
Product Weight
5.5 lb
Compliances
Contact Manufacturer
Certifications
UL Listed
Amperage Rating
80 A
Voltage rating
690 Vac, 750 Vdc
Trip Type
T268
Circuit breaker type
NZMN2
Frame
NZM2
Class
Distribution circuit protection
Accessories
Rocker lever, motor drive
Interrupt rating
50 kAIC
Connection
Screw
Number of poles
Three-pole
Feature → Business Impact → Application: The NZMN2-A80-NA is a three-pole molded case circuit breaker built on the NZM2 frame, delivering reliable three-phase protection for distribution panels. This configuration reduces the risk of asymmetric faults and simplifies panel wiring, improving setup times for industrial controls and commercial electrical rooms. The 80 A rating aligns with standard load profiles in many manufacturing lines, enabling precise current limiting while supporting scalable protection for future expansion. Feature → Business Impact → Application: The thermal-magnetic trip type provides fast, coordinated fault detection, minimizing downtime and extending equipment life in high-demand motor loads and drive systems. Application includes motor drives and process equipment where predictable trips save maintenance costs and avoid cascading faults in automation environments. Feature → Business Impact → Application: A 50 kAIC interrupt rating offers robust fault interruption, increasing safety margins for feeders and distribution circuits across industrial facilities. This translates to lower risk during short-circuits and easier compliance with electrical codes in heavy-duty installations. Feature → Business Impact → Application: Screw terminals and the rocker lever with motor drive accessory support straightforward installation and operation, reducing commissioning time and tool requirements in control cabinets. Application spans new builds and retrofit projects where space and speed matter. Feature → Business Impact → Application: The compact dimensions and weight of approximately 5.5 lb support easy integration into crowded panels or switchgear racks, enabling more efficient panel design and maintenance workflows. Long-tail keywords integrated: three-pole molded case circuit breaker, NZM2 frame, 80 A breaker, 690 Vac, 750 Vdc, 50 kAIC, motor drive compatibility, rocker lever, screw connections, distribution circuit protection.
Get a Quick Quote for a Eaton NZMN2-A80-NA
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton NZMN2-A80-NA?
Enquire Now
FAQs
Begin by verifying panel rating compatibility with 690 Vac / 750 Vdc and the NZM2 frame. Use screw terminals for secure connections, mount the breaker in the panel rail, and engage the rocker lever for ON/OFF control. Torque values should follow manufacturer guidance and ensure clear labeling for maintenance personnel. The device supports motor drive accessories for enhanced control and protection in automated systems.
The unit is rated for 80 A with a voltage rating of 690 Vac and 750 Vdc. It features a thermal-magnetic trip (T268) and an interrupt rating of 50 kAIC, with three poles and an NZMN2 circuit breaker type on an NZM2 frame. This combination supports distribution protection across typical industrial and commercial applications.
Yes. The NZMN2-A80-NA includes rocker lever operation and is compatible with motor drive accessories, enabling safe protection for motor loads and drive circuits within automation and process control environments. Ensure proper coordination with drive protections and follow installation practices to maximize uptime.
The product carries UL Listed certification, confirming compliance with recognized safety standards for electrical protection devices. Compliance details and any additional regulatory requirements should be confirmed with Eaton and local electrical codes. Always verify labeling and datasheets during procurement and installation.
Expect reduced maintenance due to a robust thermal-magnetic trip design and reliable mechanical operation. The 50 kAIC interrupt rating provides strong fault tolerance, minimizing downtime during faults and safeguarding connected equipment. Proper installation, routine visual checks, and adherence to torque specs help maximize panel uptime and return on investment.