Eaton OSP10M-BK Occupancy Sensor Switch - cULus Listed
Part Number: OSP10M-BK
Quick Summary
The Eaton occupancy sensor switch automatically controls lighting in commercial spaces, delivering hands-free, energy-saving operation. It addresses wasted energy from missed signals and manual overrides by providing reliable auto-on/off across busy work environments. The device carries cULus Listed NOM certification and supports 120/277 V loads with both 1-pole and 3-way configurations, aligning with common safety requirements. Its decorator flush design integrates discreetly into standard wall boxes, while compatibility with LED, CFL, INC, and ELV loads enables standardized controls across facilities, driving procurement efficiency and consistent lighting performance across portfolios.
Product Information
Extended Description
OSP10M-BK Eaton: Eaton occupancy sensor switch, Decorator, Flush, 120/277V, Wire lead, Black, Inc, MLV, ELV, Flr, halo, CFL, LED, Elec mtr lds, 1-pole, 3-way, 1-ph, 1000 sq ft, 2-rly, 800W (Inc/hal @120V), 1200W (Flr @120V), 2200W (Flr @277V) 729348
Product Name
Eaton occupancy sensor switch
Catalog Number
OSP10M-BK
UPC
032664729348
Product Length/Depth
4.63 in
Product Height
2.19 in
Product Width
3 in
Product Weight
50.738 lb
Certifications
cULus Listed NOM
Special features
Decorator
Type
Occupancy sensor switch
Voltage rating
120/277 V
Number Of Poles
Single-pole
Phase
Single-phase
Power consumption
1200 W (FLR at 120 V) 2200 W (FLR at 277 V) 800 W (INC/HAL at 120 V)
Wiring method
Wire leads
Sensor type
Occupancy
Mounting method
Flush
Closure type
Maintained
Load type
LED MLV Electrical motor loads ELV CFL INC HAL FLR
Number of ways
Three-way
Relay
Single
Range
1000 sq ft
Color
Black
Arrow Hart commercial lighting controls brochure
Eaton Specification Sheet - OSP10M-BK
Eaton Specification Sheet - OSP10M-BK
Feature: Decorator, Flush-mount design with wire leads enables a sleek, unobtrusive installation that blends with architectural finishes. Business Impact: Improves aesthetics while simplifying wiring, reducing field modifications and call-backs. Application: Offices, corridors, and reception areas where appearance matters and quick installs are prioritized. Feature: 1-pole and 3-way configurations provide flexible control across single- and multi-location circuits. Business Impact: Enables centralized occupancy sensing with minimal hardware changes, cutting installation time and reducing commissioning effort. Application: Open-plan workspaces and conference rooms requiring multiple control points. Feature: Supports LED, CFL, INC, MLV, ELV, and motor loads with defined wattage ratings (800 W INC/HAL at 120 V; 1200 W FLR at 120 V; 2200 W FLR at 277 V). Business Impact: Streamlines procurement by covering diverse fixtures without adding separate sensors; reduces inventory and spares. Application: Mixed-load commercial spaces and retrofit projects to standardize controls. Feature: Range up to 1000 sq ft with maintained (closure) operation ensures reliable room coverage and predictable lighting behavior. Business Impact: Improves occupant comfort and energy savings in typical office and classroom footprints. Application: Open areas, lobbies, and small conference rooms. Feature: Wire-lead wiring method simplifies field connections and reduces installation time. Business Impact: Lowers labor costs and minimizes wiring errors during retrofit projects. Application: Retrofit installations in existing boxes and new construction alike. Feature: Decorator finish in black provides a neutral, professional look that matches modern interiors. Business Impact: Enhances user acceptance and reduces aesthetic complaints in commercial environments. Application: Administrative spaces, retail backrooms, and hospitality corridors.
Get a Quick Quote for a Eaton OSP10M-BK
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton OSP10M-BK?
Enquire Now
FAQs
Begin by turning off power at the breaker. Remove the existing device, connect line and load conductors to the sensor's appropriate leads, attach ground, and cap any unused conductors. For 1-pole or 3-way configurations, follow the included wiring diagram. Mount the decorator flush unit into the wall box and restore power to test operation.
Yes. The OSP10M-BK is rated for LED, CFL, INC, MLV, ELV, and other compatible loads. At 120 V it handles up to 800 W forInc/Hal, up to 1200 W for FLR, and at 277 V up to 2200 W for FLR, enabling broad compatibility across modern office fixtures and retrofit projects.
The device is a decorator, flush-mount sensor with wire-lead wiring for easy field connections. It supports single-pole and three-way configurations, providing flexible control for both standalone and multi-location lighting systems in commercial spaces.
The OSP10M-BK carries cULus Listed NOM certification, aligning with recognized electrical safety standards for commercial installations and helping mitigate compliance risk during audits and inspections.
Expect energy savings from automatic occupancy-based control, reduced maintenance due to fewer manual switches, and extended lamp life from controlled on/off cycles. The 1000 sq ft coverage and robust 120/277 V compatibility support standardized controls across facilities, improving procurement consistency and long-term operating costs.