Eaton P3BEDH3150 Pow-R-Way III Plug-in Unit - UL/CSA
Part Number: P3BEDH3150
Quick Summary
Eaton P3BEDH3150 is a Pow-R-Way III circuit breaker plug-in unit protecting busways in industrial power distribution. Project teams often struggle with integration gaps, space constraints, and lengthy commissioning. This model carries IEEE Certified, CSA Certified, ANSI, and UL 857 certifications, plus NEMA compliance for standard enclosure environments. With a 150A rating and a 100 kAIC interrupt rating at 240 Vac, it delivers robust protection while simplifying installation. By leveraging EDH frame compatibility and a plug-in design, it reduces downtime and lifecycle costs, enabling quicker replacements and streamlined spare parts management for capital projects and ongoing maintenance.
Product Information
Extended Description
P3BEDH3150 Eaton: Pow-R-Way III Busway, Circuit Breaker Plug-in Unit, 3-Pole, 150 AMP, EDH Frame Type
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BEDH3150
UPC
786683005173
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Compliances
NEMA Compliant
Certifications
IEEE Certified CSA Certified ANSI UL 857
Circuit Breaker Frame
E
Grounding Options
50% Integral/Housing
Type
Breaker
Amperage Rating
150A
Interrupt rating
100 kAIC at 240 Vac
The Busway Solution
Eaton Specification Sheet - P3BEDH3150
Selling Policy 25-000 - Distribution and Control Products and Services
Feature: 3-Pole design with a 150A amperage rating → Business Impact: Provides reliable three-phase protection for medium-load feeders, minimizing nuisance trips while enabling predictable performance → Application: Industrial power distribution in manufacturing lines and process facilities. Feature: 100 kAIC interrupt rating at 240 Vac → Business Impact: High fault clearance capability reduces damage to busways and downstream equipment, lowering repair costs and downtime → Application: Critical load feeders and data-center-style environments. Feature: 50% integral grounding options → Business Impact: Simplifies grounding topology and reduces external hardware, cutting installation time and potential fault paths → Application: Field installations with compact control panels and limited cabinet space. Feature: EDH frame type compatibility with plug-in unit design → Business Impact: Fast replacement and easy upgrading without rewiring, improving maintainability and reducing downtime → Application: Retrofit projects and new builds using Pow-R-Way III busways. Feature: Certifications and compliance (IEEE, CSA, ANSI, UL 857) plus NEMA compliance → Business Impact: Ensures regulatory alignment and safer procurement, smoothing vendor qualification and audit processes → Application: Aerospace and general manufacturing, where standard certifications are mandatory. Feature: Compact dimensions and weight (12.36 in depth, 21.2 in height, 5.43 in width; 25 lb) → Business Impact: Space-efficient footprint supports dense panel layouts and easier shipping/handling → Application: Enclosures with tight footprints and field service constraints.
Get a Quick Quote for a Eaton P3BEDH3150
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton P3BEDH3150?
Enquire Now
FAQs
Yes. The P3BEDH3150 is designed as a 3-Pole, plug-in circuit breaker unit compatible with Eaton Pow-R-Way III busways and the EDH frame type. Its 12.36 in depth, 21.2 in height, and 5.43 in width provide a compact footprint suitable for standard installations, with a 25 lb weight for manageable handling during retrofit or new builds.
The unit features a 150A amperage rating and an interrupt rating of 100 kAIC at 240 Vac. These ratings support reliable fault interruption for medium-load feeders and high-energy protection in busway systems, enabling safe operation of critical loads in factory floors and process lines.
Ideal for industrial power distribution in manufacturing, process industries, and data-center facilities that rely on Pow-R-Way III busways. Its robust certifications (IEEE, CSA, ANSI, UL 857) and NEMA compliance make it suitable for regulated environments requiring dependable protection and standardization across sites.
The unit is IEEE Certified, CSA Certified, ANSI, and UL 857 listed, with NEMA compliance. These certifications support regulatory alignment, safer procurement, and smoother audits across global manufacturing facilities, helping customers meet internal and external compliance requirements.
The plug-in design simplifies replacement and maintenance, reducing downtime during servicing and upgrades. Grounding options, compact dimensions, and modular EDH frame compatibility minimize field customization, while the high interrupt rating provides long-term protection, contributing to lower total cost of ownership for installed busway systems.