Eaton P3BEHD3040G Circuit Breaker Plug-in Unit - 18 kAIC at 240V

Part Number: P3BEHD3040G
Manufacturer
Eaton
Part number
P3BEHD3040G

Quick Summary

The Eaton P3BEHD3040G circuit breaker plug-in unit provides reliable overcurrent protection for Pow-R-Way III busway. Maintenance and upgrades in live busway installations can create project delays and safety risks. IEEE Certified, CSA Certified, and UL 857 compliance support regulatory goals while delivering dependable protection. As part of Eaton's Pow-R-Way III family, it enables fast plug-in installation, robust grounding, and scalable power distribution. For procurement teams, specifying this unit reduces variance across installs with a single, standardized plug-in design. Engineers benefit from a known performance envelope—40A rating, 18 kAIC at 240V, and 14 kAIC at 480V—while maintaining NEMA compliance. This combination supports faster maintenance cycles, lower total cost of ownership, and safer, compliant operations.

Product Information

Extended Description

P3BEHD3040G Eaton: Pow-R-Way III Busway, Circuit Breaker Plug-in Unit, 3-Pole, 40 AMP, EHD Frame Type, 50% Internal Ground
Product Name
Eaton Pow-R-Way III circuit breaker plug-in unit
Catalog Number
P3BEHD3040G
UPC
786683005548
Product Length/Depth
12.36 in
Product Height
21.2 in
Product Width
5.43 in
Product Weight
25 lb
Compliances
NEMA Compliant
Certifications
IEEE Certified CSA Certified ANSI UL 857
Circuit Breaker Frame
E
Grounding Options
50% Internal
Type
Breaker
Amperage Rating
40A
Interrupt rating
18 kAIC at 240 Vac, 14 kAIC at 480 Vac
3-Pole, 40A rating paired with a 50% internal grounding design reduces wiring complexity and improves fault path control, delivering faster protection across the Pow-R-Way III busway. This means easier field wiring, reduced installation errors, and a smaller panel footprint, enabling tighter equipment layouts in commercial facilities. The unit's 18 kAIC at 240 VAC and 14 kAIC at 480 VAC handle high fault currents with confidence, limiting damage to downstream equipment and shortening outage times. This performance translates to lower risk during commissioning and a more predictable power profile for critical loads. IEEE Certified, CSA Certified, ANSI, UL 857, and NEMA compliance provide regulatory confidence for industrial environments and data centers alike, supporting safer, audit-ready operations. Compact dimensions — 12.36 in depth, 21.2 in height, 5.43 in width — and a 25 lb weight ensure straightforward mounting within standard Pow-R-Way III frames, with a plug-in design that minimizes wiring and commissioning time. 50% Internal grounding simplifies the grounding scheme, reducing external conductors, while the E-frame configuration ensures interchangeability with other P3 series plug-in units in the same family. Industry practitioners increasingly favor modular, certified protection for busway deployments, and this plug-in unit supports rapid retrofits, scalable protection, and consistent lifecycle performance. Compatibility and installation advantages are built in. The unit is designed for straightforward plug-in installation into Pow-R-Way III busways, minimizing field wiring, reducing commissioning time, and supporting rapid retrofit projects. Its 3-Pole, 40A rating aligns with common distribution feeds in commercial facilities, making it a natural upgrade path for aging busway circuits. Addressing common objections, this plug-in unit offers a clearly defined performance envelope with known interrupt ratings and grounding options, reducing risk during start-up and expansion. The combination of IEEE, CSA, ANSI, and UL 857 certifications, along with NEMA compliance, helps with regulatory audits, supplier qualification, and long-term maintenance planning. Field teams benefit from accessible installation manuals and Eaton datasheets, including the official specification sheet.

Get a Quick Quote for a Eaton P3BEHD3040G

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton P3BEHD3040G? Enquire Now

FAQs

To optimize compatibility, use the P3BEHD3040G with Pow-R-Way III busways that support 3-Pole, 40A plug-in breakers. Verify the E frame type, 50% internal grounding option, and the unit’s 12.36 in depth, 21.2 in height, and 5.43 in width to fit within the designated busway cavity. Ensure correct panel labeling and follow Eaton’s installation guidelines for plug-in modules to minimize torque and seating variances.
The unit is a 3-Pole, 40A circuit breaker with 50% internal grounding. It provides interrupt ratings of 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, suitable for protecting Pow-R-Way III busway circuits in commercial and light industrial applications.
Yes. It carries IEEE Certified, CSA Certified, ANSI, and UL 857 certifications and aligns with NEMA Compliant requirements, supporting safe operation and regulatory compliance across industrial environments.
Benefits include fast plug-in installation, robust high-current protection, and standardized performance across installations. The 18 kAIC/14 kAIC interrupt ratings help minimize fault damage, while 50% internal grounding simplifies grounding strategies in tight spaces, reducing wiring complexity and downtime.
Maintenance impact is reduced due to a modular, plug-in design, consistent performance, and widely recognized certifications. The unit’s standardized specifications and documentation support faster commissioning, lower lifecycle costs, and improved asset reliability in both new installations and retrofits.